Мы предоставляем клиентам различные коммуникационные продукты по разумным ценам и высококачественным продуктам и услугам
机柜安装标准
|
- The device can be installed in a standard 19" cabinet with a depth not less than 1000 mm. It can be equipped with a noise
reduction module if being installed in a 1200 mm-deep cabinet. |
- By default, the 0.6m (wide) x 1.2 m (deep) x 2.2 m (high) Huawei A612 cabinet (part number: 02116249) is installed.
| |
- You can also choose the 0.6m (wide) x 1.0 m (deep) x 2.2 m (high) Huawei A610 cabinet (part number: 02116250) with a convex
front door. | |
- The front door of the cabinet must be equipped with an air filter, but the rear door of the cabinet cannot be equipped with any
air filter. (If an air filter is installed on the rear door, uninstall it.) | |
宽[毫米]
|
442 毫米
|
深度[毫米]
|
874 毫米
|
高度[毫米]
|
438 毫米
|
底盘高度[U]
|
9.8
|
不含包装的重量 [kg(lb)]
|
76 (167.55)
|
最大功耗[W]
|
3660
|
最大散热量 [BTU/小时]
|
12488
|
供电方式
|
AC built-in,HVDC built-in
|
额定输入电压[V]
|
- AC: 220 V, 50 Hz/60 Hz
|
- High-voltage DC: 240 V/380 V
| |
输入电压范围[V]
|
- AC: 176–290 V; 45–65 赫兹
|
- High-voltage DC (HVDC): 188 V to 288 V or 260 V to 400 V
| |
Maximum input current [A]
|
- AC: 16 A/power module @ 200 V; 18.5 A/power module @ 176 V
|
- High-voltage DC (HVDC): 18 A/power module @ 188 V; 13 A/power module @ 260 V
| |
Number of slots
|
15
|
Number of service board slots
|
4 |
Number of MPU slots
|
2 |
风扇模块数量
|
3 |
粉丝类型
|
可插拔
|
长期工作温度[°C(°F)]
|
0°C 到 40°C (32°F 至 104°F)
|
储存温度[°C(°F)]
|
-40ºC 至 +70ºC (-40°F to +158°F)
|
长期工作相对湿度[RH]
|
5% RH to 85% RH, noncondensing
|
储存相对湿度[RH]
|
5% RH to 85% RH, noncondensing
|
长期工作高度 [m(ft.)]
|
<000000>le; 5000 m (16404 ft.)
|
存储海拔高度 [米(英尺)]
|
<000000>le; 5000 m (16404 ft.)
|
平均无故障时间 [年]
|
34.93
|
平均修复时间 [小时]
|
1 |
Availability
|
0.99999717
|
Электронная почта:
Lilicheng0510@163.com
Flat/RM P, 4/F, Lladro Center, 72 Hoi Yuen Road, Квун Тонг, Гонконг, Китай