Description | Part Number | Model | First supported version |
---|---|---|---|
NE08E-S6E Assembly Chassis(-48V) | 02311NPF | NEDB00CASE00 | V300R001C10 |
NE08E-S6E Assembly Chassis(-48V) | 02311YFJ | NEDB00CASE02 | V300R003C00 |
On the NE08E-S6E an interface is numbered in the format of "CXP slot number/PIC number/port number". The following part describes the details:
Logical slot number of the system control board
It is the logical slot number of the CXP, The logical slot number is always 0.
Physical interface card number
It is the slot number of the physical interface card where service interfaces reside. The physical interface card numbers on the NE08E-S6E range from 1 to 6.
Port number
The port numbers of service interfaces on a physical interface card begin with 0. Port numbering depends on the number of interfaces on the physical interface card.
Item | Specification |
---|---|
Cabinet installation standards | R01S200 Outdoor Cabinet, ETSI(21-inch), IEC(19-inch), IMB(3U) |
Dimensions without packaging (H x W x D) [mm(in.)] | 88.9 mm x 442 mm x 220 mm (3.5 in. x 17.4 in. x 8.66 in.) |
Chassis height [U] | 2 U |
Weight without packaging [kg(lb)] | 3.5 kg (7.72 lb) |
Weight without packaging (full configuration) [kg(lb)] | 9.3 kg (20.51 lb) |
Typical power consumption (with configuration) [W] |
2 channel DC System, with CXP Protection:113 W 2 channel DC System, without CXP Protection:58 W |
Typical heat dissipation (with configuration) [BTU/hour] |
2 channel DC System, with CXP Protection:366.6 BTU/hour 2 channel DC System, without CXP Protection:188.2 BTU/hour |
MTBF [year] | 40 year |
MTTR [hour] | 2 hour |
Availability | 0.99999 |
Power supply mode | DC |
Rated input voltage [V] | –48 V/–60 V |
Input voltage range [V] | -38.4 V to -72 V |
Maximum input current [A] | 20 A |
Maximum input cable size [mm²] | 4mm^2(10m) |
Front-end circuit breaker/fuse [A] | ≥ 25 A |
Heat dissipation mode | Air cooling |
Airflow direction | From left to right |
Noise at normal temperature (acoustic power) [dB(A)] | 55 dB(A), 160G system |
Number of slots | 11 |
Number of service board slots | 6 |
Switching capacity | 352 Gbit/s (Bidirectional). The maximum allowed error is 0.01%. To be specific, 99.99% of the line rate is guaranteed. |
Redundant CXPs | 1:1 |
Redundant power supply | 1+1 |
Redundant fans | If a single fan fails, the system can still work for a short period of time at an ambient temperature of 40°C. |
Long-term operating temperature [°C(°F)] | –40°C to +65°C (–40°F to +149°F) |
Restriction on the operating temperature variation rate [°C(°F)] | ≤ 30°C/hour (54°F/hour) |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158 °F) |
Long-term operating relative humidity [RH] | 5% to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% to 100% RH, non-condensing |
Long-term operating altitude [m(ft.)] | ≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].) |
Storage altitude [m(ft.)] | < 5000 m (16404 ft.) |
Q: How about your main products?
Email: Lilicheng0510@163.com