Description | Part Number | Model | First supported version |
---|---|---|---|
NE05E-SR System,Indoor,AC,2*GE/FE Combo,2*GE/FE(o),2*GE/FE(e) | 02351XAG | NECM000AIC01 | V300R003C10 |
On the NE05E-SR, an interface is numbered in the format of "slot number/subcard number/port number". The following part describes the details:
Slot number
The slot number of NE05E-SR is always 0.
Subcard number
The NE05E-SR does not support subcards. Therefore, the subcard number of the NE05E-SR is fixed as 2.
Port number
The port numbers of service interfaces on the NE05E-SR begin with 0. Port numbering depends on the number of interfaces on the NE05E-SR.
Item | Specification |
---|---|
Cabinet installation standards | ETSI (21-inch); IEC (19-inch); IMB (3U) |
Dimensions without packaging (H x W x D) [mm(in.)] | 43.6 mm x 250 mm x 180 mm (1.72 in. x 9.8 in. x 7.1 in.) |
Chassis height [U] | 1 U |
Weight without packaging [kg(lb)] | 1.7 kg (3.75 lb) |
Typical power consumption (with configuration) [W] | 12.8 W |
Typical heat dissipation (with configuration) [BTU/hour] | 41.5 BTU/hour |
MTBF [year] | 40 year |
MTTR [hour] | 2 hour |
Availability | 0.99999 |
CPU | 4-core 800M |
SDRAM | 2 GB |
Flash memory | 32 MB |
Storage | 1 GB |
Power supply mode | AC |
Rated input voltage [V] | 110 V/220 V |
Input voltage range [V] | 100 V to 240 V |
Maximum input current [A] | 0.85 A |
Maximum input cable size [mm²] | Standard C13 cable |
Front-end circuit breaker/fuse [A] | 2 A |
Heat dissipation mode | Natural heat dissipation |
Noise at normal temperature (acoustic power) [dB(A)] | No noise |
Switching capacity | 12 Gbit/s (Bidirectional). The maximum allowed error is 0.01%. To be specific, 99.99% of the line rate is guaranteed. |
Redundant power supply | Not support |
Redundant fans | No fan |
Long-term operating temperature [°C(°F)] | -40°C to 60°C (-40°F to 140°F) |
Restriction on the operating temperature variation rate [°C(°F)] | ≤ 30°C/hour (54°F/hour) |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158 °F) |
Long-term operating relative humidity [RH] | 5% to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% to 100% RH, non-condensing |
Long-term operating altitude [m(ft.)] | ≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].) |
Storage altitude [m(ft.)] | < 5000 m (16404 ft.) |
Q: How about your main products?