HW NetEngine 8000 series routers provide an all-service, intelligent router platform designed for the cloud era.
Using ultra-broadband pipes to construct simplified networks, and Segment Routing (SR) and Segment Routing over IPv6 (SRv6) protocols to establish intelligent connections, NetEngine 8000 combines with HW's next generation Network Cloud Engine (NCE) to implement full-lifecycle automation and proactive Operations and Maintenance (O&M). An intent-driven approach frees customers from unnecessary constraints, unleashing network potential.
Available in a range of form factors and applicable to core, aggregation, and access networks, the award-winning NetEngine 8000 offers high performance and reliability, with low power consumption and full evolution capabilities. Applications include functioning as a core node for an enterprise Wide Area Network (WAN), as an access node on a large enterprise network, as a Data Center Interconnect (DCI) node, or as a campus or Internet Data Center (IDC) network egress..
Item | Specification |
---|---|
Cabinet installation standards |
|
Dimensions without packaging (H x W x D) [mm(in.)] |
|
Dimensions with packaging (H x W x D) [mm(in.)] | 990 mm x 770 mm x 1150 mm(38.98 in. x 30.31 in. x 45.28 in.) |
Chassis height [U] | 15.8 U |
Weight without packaging [kg(lb)] | 94 kg (207.2 lb) |
Weight with packaging [kg(lb)] | 177 kg (390.2 lb) |
Weight without packaging (full configuration) [kg(lb)] |
4T bundle: 308.5 kg (680.1 lb) 14.4T bundle: 340.5kg (750.7 lb) |
Typical power consumption (with configuration) [W] | 10256 W (estimated value when LPUI-4T boards are fully configured) |
Typical heat dissipation (with configuration) [BTU/hour] | 32665 BTU/hour |
MTBF [year] | 18.61 year |
MTTR [hour] | 0.5 hour |
Availability | 0.99999 |
Power supply mode | AC/HVDC built-in |
Maximum number of power chassis inputs | (20 channels/PEM)*1 PEM=(2 channels/PM)*10 PM*1 PEM=20 channels |
Rated input voltage [V] |
|
Input voltage range [V] |
|
Maximum input current [A] |
|
Maximum input cable size [mm²] | 2.5 mm² |
Front-end circuit breaker/fuse [A] |
AC:
HVDC: 2x20 A per module, 10 PMs, 20x20 A required in total |
Heat dissipation mode | air cooling |
Airflow direction | Front-to-back airflow |
Number of slots | 18 |
Number of service board slots | 8 |
Switching capacity |
83.78 Tbit/s 14.4T bundle: 346.3 Tbit/s |
Redundant MPUs | 1:1 |
Redundant Switch fabrics | 7+1 |
Redundant power supply | 7+1 |
Redundant fans | 3 assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) |
Long-term operating temperature [°C(°F)] | 0 °C to 40 °C (32°F to 104°F) |
Short-term operating temperature [°C(°F)] | -5 °C to 50 °C (23°F to 122°F) |
Restriction on the operating temperature variation rate [°C(°F)] | ≤ 30°C/hour (54°F/hour) |
Storage temperature [°C(°F)] | -40 °C to 70 °C(–40°F to 158°F) |
Long-term operating relative humidity [RH] | 5% to 85%, non-condensing |
Short-term operating relative humidity [RH] | 5% to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | ≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device decreases by 1°C [33.8°F] each time the altitude increases by 220 m [721.78 ft.].) |
Storage altitude [m(ft.)] | < 5000 m (16404.199 ft.) |