Item
|
Specification
|
Cabinet installation standards
|
ETSI 21-inch; IEC 19-inch
|
Dimensions without packaging (H x W x D) [mm(in.)]
|
88.9 mm x 442 mm x 220 mm (3.5 in. x 17.4 in. x 8.66 in.)
|
Dimensions with packaging (H x W x D) [mm(in.)]
|
335 mm x 585 mm x 390 mm (13.19 in. x 23.03 in. x 15.35 in.)
|
Chassis height [U]
|
2 U
|
Weight without packaging [kg(lb)]
|
4.2 kg (9.26 lb)
|
Weight with packaging [kg(lb)]
|
6.9 kg (15.21 lb)
|
Weight without packaging (full configuration) [kg(lb)]
|
[CXP-160/CXP-160-B]DC:10.65kg(23.48 lb)
|
Weight with packaging (full configuration) [kg(lb)]
|
[CXP-160/CXP-160-B]DC:13.39kg(29.52 lb)
|
Typical power consumption (with configuration) [W]
|
[CXP-160/CXP-160-B]DC Typical configuration 1: 2*CXP+1*FAN+2*DC power+2*CR8D00L4XFC0 + 2*CR8D00EAGFC0 =196.1 W
|
[CXP-160/CXP-160-B]DC Typical configuration 2: 2*CXP+1*FAN+2*DC power+2*CR8D00E1VBC0+1*CR8D00L4XFC0 + 1*CR8D00EAGFC0 =205.8 W
|
|
Typical heat dissipation (with configuration) [BTU/hour]
|
[CXP-160/CXP-160-B]DC Typical configuration 1: 2*CXP+1*FAN+2*DC power+2*CR8D00L4XFC0 + 2*CR8D00EAGFC0 =285.9 BTU/hour
|
[CXP-160/CXP-160-B]DC Typical configuration 2: 2*CXP+1*FAN+2*DC power+2*CR8D00E1VBC0+1*CR8D00L4XFC0 + 1*CR8D00EAGFC0 =317.41
BTU/hour |
|
MTBF [year]
|
163.45 year
|
MTTR [hour]
|
0.5 hour
|
Availability
|
0.999999651
|
Power supply mode
|
DC
|
Rated input voltage [V]
|
–48 V/–60 V
|
Input voltage range [V]
|
–40 V to –72 V
|
Maximum input current [A]
|
30 A
|
Rated output power [W]
|
1200 W
|
Maximum input cable size [mm²]
|
4mm^2 (0-14m)
|
Front-end circuit breaker/fuse [A]
|
≥ 16 A (Based on long-term evolution requirements and site conditions, the recommended current is greater than or equal to 32 A.)
|
Heat dissipation mode
|
Air cooling
|
Airflow direction
|
From left to right
|
Noise at normal temperature (acoustic power) [dB(A)]
|
< 55 dB(A)
|
Number of slots
|
11
|
Number of service board slots
|
6
|
Switching capacity
|
320 Gbit/s
|
Redundant CXPs
|
1:01
|
Redundant power supply
|
1+1
|
Redundant fans
|
1+1. Short-term running when a single fan becomes invalid at the ambient temperature of 40°C (104°F)(one fan module contains two
fans) |
Long-term operating temperature [°C(°F)]
|
-40°C to 65°C(-40°F to 149°F)
|
Restriction on the operating temperature variation rate [°C(°F)]
|
≤ 30°C/hour (54°F/hour)
|
Storage temperature [°C(°F)]
|
-40°C to 70°C(-40°F to 158°F)
|
Long-term operating relative humidity [RH]
|
5% to 85% RH, non-condensing
|
Short-term operating relative humidity [RH]
|
5% to 95% RH, non-condensing
|
Storage relative humidity [RH]
|
5% to 95% RH, non-condensing
|
Long-term operating altitude [m(ft.)]
|
≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature
of the device decreases by 1°C [33.8°F] each time the altitude increases by 220 m [721.78 ft.].) |
Storage altitude [m(ft.)]
|
< 5000 m (16404.199 ft.)
|
1.Table And Wide Supply Chain System
We have established a perfect supply chain system to provide a wide range of products with reliable quality and reasonable price.
2.Competitive Price
We ensure the most competitive price.Warm reminders here, telecommunications equipment configuration is quite different, the price show
3.Safe And Easy Payment Solutions
We support a variety of payment methods, such as T/T, credit card, et
4.Strong Pre-Sales And After-Sales Services
To provide customers with professional pre- sales service, as well as after-sales technical Services
5.More Than 20 Years Industry Experience
We have been engaged in this industry more than 20 years, we have rich industry experience.
6.Fast Delivery And Shipping
Fast, professional and reliable delivery.
Q: How about your main products?
A:Our product lines include Switches.Routers,OLTs,SDHs. Network Modules, Interface Cards, Security Firewalls, Wireless AP etc.
Email: Lilicheng0510@163.com