Chassis material
|
Metal
|
Height [mm]
|
43.6 mm
|
Depth [mm]
|
420.0 mm
|
Wide [mm]
|
442.0 mm
|
Chassis height [U]
|
1
|
Weight with packaging [kg(lb)]
|
7.35 kg (16.2 lb)
|
Weight without packaging [kg(lb)]
|
4.90 kg (10.8 lb)
|
Maximum power consumption [W]
|
- 62.29 W (with two 80 W AC power modules) - 61.77 W (with two 240 W DC power modules)
|
Typical power consumption [W]
|
52.51
|
Heat dissipation mode
|
Air cooling for heat dissipation, intelligent fan speed adjustment
|
Maximum heat dissipation [BTU/hour]
|
- 212.54 (with two 80 W AC power modules) - 210.77 (with two 240 W DC power modules)
|
Typical heat dissipation [BTU/hour]
|
179.17
|
Power supply mode
|
Pluggable power supply
|
Input voltage range [V]
|
- AC input: 90 V AC to 290 V AC; 45–65 Hz - High-voltage DC input: 190 V DC to 290 V DC - DC input: -38.4 V DC to -72 V DC
|
Rated input voltage [V]
|
- AC input: 100 V AC to 240 V AC; 50/60 Hz - High-voltage DC input: 240 V DC - DC input: –48 V DC to –60 V DC
|
Maximum input current [A]
|
The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules.
|
Number of power slots
|
2
|
Number of card slots
|
1
|
Memory
|
2 GB
|
Flash memory
|
Physical space: 1 GB
|
Redundant power supply
|
1+1 Power modules without fans and power modules with fans cannot be installed in the same chassis.
|
Types of fans
|
Built-in
|
Noise at normal temperature (acoustic power) [dB(A)]
|
47
|
Noise at normal temperature (acoustic pressure) [dB(A)]
|
35
|
Airflow direction
|
Air intake from left, front, and right and air exhaust from rear
|
Storage temperature [°C(°F)]
|
–40°C to +70°C (–40°F to +158°F)
|
Long-term operating temperature [°C(°F)]
|
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.)
|
Restriction on the operating temperature variation rate [°C(°F)]
|
When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F).
|
Long-term operating relative humidity [RH]
|
5% RH to 95% RH (non-condensing)
|
Storage altitude [m(ft.)]
|
0-5000 m (0-16404 ft.)
|
Long-term operating altitude [m(ft.)]
|
0–5000 m (0–16404 ft.)
|
MTBF [year]
|
57.88
|
MTTR [hour]
|
2
|
Availability
|
> 0.99999
|
Maximum number of physical ports on the entire device
|
38
|
Maximum number of 100GE ports
|
0
|
Maximum number of 40GE ports
|
0
|
Maximum number of 25GE ports
|
0
|
Maximum number of 10GE ports
|
6
|
Maximum number of GE ports
|
36
|
Maximum number of FE ports
|
32
|
10GE optical interface
|
2
|
1000M electrical interface
|
24
|
USB
|
Supported
|
Console port
|
RJ45
|
Eth Management port
|
RJ45
|
Power supply surge protection
|
- Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode - Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode
|
RPS input
|
Not supported
|
PoE
|
Not supported
|