Item
|
Specification
|
Dimensions without packaging (H x W x D) [mm(in.)]
|
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.)
|
|
Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm
x 442.0 mm x 236.0 mm (1.72 in. x 17.4 in. x 9.29 in.) |
Dimensions with packaging (H x W x D) [mm(in.)]
|
90 mm × 550 mm × 360 mm (3.54 in. x 21.65 in. x 14.17 in.)
|
Chassis height [U]
|
1 U
|
Weight without packaging [kg(lb)]
|
4.09 kg (9.02 lb)
|
Weight with packaging [kg(lb)]
|
4.71 kg (10.38 lb)
|
Typical power consumption [W]
|
30% traffic under the ATIS standard:
|
|
101 W
|
Typical heat dissipation [BTU/hour]
|
30% traffic under the ATIS standard:
|
|
313.91
|
Maximum power consumption [W]
|
100% traffic under the ATIS standard:
|
|
105 W
|
Maximum heat dissipation [BTU/hour]
|
100% traffic under the ATIS standard:
|
|
358.27
|
Static power consumption [W]
|
59 W
|
MTBF [years]
|
45.5 years
|
MTTR [hours]
|
2.64 hours
|
Availability
|
> 0.99999
|
Noise at normal temperature (acoustic power) [dB(A)]
|
47.2 dB(A)
|
Noise at normal temperature (acoustic pressure) [dB(A)]
|
35.2 dB(A)
|
Number of card slots
|
0
|
Number of power slots
|
0
|
Number of fans modules
|
2
|
Redundant power supply
|
Not supported
|
Long-term operating temperature [°C(°F)]
|
–5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.44 ft.)
|
Short-term operating temperature [°C(°F)]
|
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.)
|
Restriction on the operating temperature variation rate [°C(°F)]
|
When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the
altitude increases by 220 m (722 ft.). |
|
The device can work for a short period of time when the operating temperature is beyond the normal range, but the following
conditions must be met: |
|
The operating temperature can exceed 45°C (113°F) for a maximum of 96 consecutive hours in a year.
|
|
The total time when the operating temperature exceeds 45°C (113°F) in a year is less than or equal to 360 hours.
|
|
The number of times the operating temperature exceeds 45°C (113°F) is less than or equal to 15 in one year.
|
|
If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur.
|
|
Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used
for short-term operation cannot exceed 10 km. |
Storage temperature [°C(°F)]
|
–40°C to +70°C (–40°F to +158°F)
|
Long-term operating relative humidity [RH]
|
5% RH to 95% RH (non-condensing)
|
Long-term operating altitude [m(ft.)]
|
0–5000 m (0–16404 ft.)
|
Storage altitude [m(ft.)]
|
0-5000 m (0-16404 ft.)
|
Power supply mode
|
AC built-in
|
Rated input voltage [V]
|
AC input: 100–240 V AC; 50/60 Hz
|
Input voltage range [V]
|
AC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz
|
Maximum input current [A]
|
3 A
|
Memory
|
4 GB
|
Flash memory
|
Physical space: 2 GB
|
Console port
|
USB
|
Eth Management port
|
RJ45
|
USB
|
Not supported
|
RTC
|
Supported
|
RPS input
|
Not supported
|
Power supply surge protection [kV]
|
Differential mode: ±6 kV; common mode: ±6 kV
|
Ingress protection level (dustproof/waterproof)
|
IP20
|
Types of fans
|
Built-in
|
Heat dissipation mode
|
Air cooling for heat dissipation, intelligent fan speed adjustment
|
Airflow direction
|
Air intake from left and air exhaust from right
|
PoE
|
Not supported
|
Certification
|
EMC certification
|
|
Safety certification
|
|
Manufacturing certification
|