غرض
|
مواصفة
|
Cabinet installation standards
|
ETSI 21-inch; IEC 19-inch
|
Dimensions without packaging (H x W x D) [mm(in.)]
|
88.1 mm x 442 mm x 220 mm (3.47 in. x 17.4 in. x 8.66 in.)
|
Chassis height [U]
|
2 U
|
Weight without packaging [kg(lb)]
|
9.4 kg (20.72 lb)
|
Weight without packaging (full configuration) [kg(lb)]
|
DC: 11.0 kg (24.26 lb)
|
AC: 12.2 kg (26.90 lb
| |
Typical power consumption (with configuration) [W]
|
DC: 271 W
|
AC: 309 W
| |
Typical heat dissipation (with configuration) [BTU/hour]
|
DC: 879.2 BTU/hour
|
AC: 1002.5 BTU/hour
| |
MTBF [year]
|
26 year
|
MTTR [hour]
|
2 hour
|
Availability
|
0.999999614
|
CPU
|
16-core, 2.0 GHz
|
SDRAM
|
16 G
|
Flash memory
|
128 MB
|
وضع إمداد الطاقة
|
DC
|
AC
| |
HVDC
| |
جهد الدخل المقدر [فولت]
|
DC: -48 V/-60 V
|
AC: 200 V to 240 V/100 V to 127 V dual live wires
| |
HVDC: 240 V
| |
نطاق جهد الإدخال [فولت]
|
DC: -48 V/-72 V
|
AC: 180 V to 264 V
| |
HYDC: 188 Vdc to 290 Vdc
| |
Maximum input current [A]
|
DC: 18 A
|
AC: 5.4 A
| |
HVDC: 4.8 A
| |
Maximum input cable size [mm²]
|
DC: 6mm^2. 4mm^2 (1-15 meters) recommended
|
AC: 1.5mm^2
| |
Front-end circuit breaker/fuse [A]
|
DC: <000000>ge;20 A
|
AC: <000000>ge;6 A
| |
HVDC: <000000>ge;6.3 A
| |
وضع تبديد الحرارة
|
Air cooling
|
اتجاه تدفق الهواء
|
From left to right
|
Noise at normal temperature (acoustic power) [dB(A)]
| < 72 dB (meeting the ETSI 72 dBA standard)
|
Number of slots
|
6 |
Number of service board slots
|
2 |
Switching capacity
|
1820 Gbit/s
|
Redundant MPUs
|
Fixed-configuration, not pluggable
|
Redundant network processing units
|
Fixed-configuration, not pluggable
|
مصدر طاقة زائد
|
1+1
|
Redundant fans
|
If a single fan fails, the system can still work for a short period of time at an ambient temperature of 40°C.
|
درجة حرارة التشغيل على المدى الطويل [°C(°F)]
|
DC: -20°C(-4°F) to 65°C(149°F)
|
AC: 0°C(33.8°F) to 45°C(113°F)
| |
Short-term operating temperature [°C(°F)]
|
AC:-5°C(23°F) to 55°C(131°F)
|
Restriction on the operating temperature variation rate [°C(°F)]
|
<000000>ليه؛ 30°C/hour (54°F/hour)
|
درجة حرارة التخزين [°C(°F)]
|
-40°C(-40°F) to 70°C(158°F)
|
Long-term operating relative humidity [RH]
|
5% RH to 90% RH, non-condensing
|
Short-term operating relative humidity [RH]
|
5% RH to 95% RH, non-condensing
|
Storage relative humidity [RH]
|
5% RH to 95% RH, non-condensing
|
Long-term operating altitude [m(ft.)]
|
<000000>le; 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature
of the device decreases by 1°C [33.8°F] each time the altitude increases by 220 m [721.78 ft.].) |
Storage altitude [m(ft.)]
| < 5000 m(< 16404.2 ft.)
|
1. نظام سلسلة التوريد الواسع والجدول
لقد أنشأنا نظام سلسلة توريد مثالي لتوفير مجموعة واسعة من المنتجات بجودة موثوقة وبسعر معقول.
2.سعر تنافسي
نحن نضمن السعر الأكثر تنافسية. تذكير دافئ هنا، تكوين معدات الاتصالات مختلف تمامًا، يظهر السعر
3.حلول دفع آمنة وسهلة
نحن ندعم مجموعة متنوعة من طرق الدفع، مثل T/T، وبطاقة الائتمان، وما إلى ذلك
4. خدمات ما قبل البيع وما بعد البيع القوية
لتزويد العملاء بخدمة ما قبل البيع الاحترافية، بالإضافة إلى الخدمات الفنية لما بعد البيع
5. أكثر من 20 عامًا من الخبرة في الصناعة
لقد عملنا في هذه الصناعة لأكثر من 20 عامًا، ولدينا خبرة غنية في الصناعة.
6. تسليم وشحن سريع
تسليم سريع واحترافي وموثوق.
س: ماذا عن منتجاتك الرئيسية؟
ج: تشمل خطوط منتجاتنا المفاتيح والموجهات وأجهزة OLT وأجهزة SDH. وحدات الشبكة، وبطاقات الواجهة، وجدران الحماية الأمنية، ونقاط الوصول اللاسلكية وما إلى ذلك.