Item
|
Specification
|
Cabinet installation standards
|
ETSI 21-inch; IEC 19-inch
|
Dimensions without packaging (H x W x D) [mm(in.)]
|
88.1 mm x 442 mm x 220 mm (3.47 in. x 17.4 in. x 8.66 in.)
|
Chassis height [U]
|
2 U
|
Weight without packaging [kg(lb)]
|
9.4 kg (20.72 lb)
|
Weight without packaging (full configuration) [kg(lb)]
|
DC: 11.0 kg (24.26 lb)
|
AC: 12.2 kg (26.90 lb
|
|
Typical power consumption (with configuration) [W]
|
DC: 271 W
|
AC: 309 W
|
|
Typical heat dissipation (with configuration) [BTU/hour]
|
DC: 879.2 BTU/hour
|
AC: 1002.5 BTU/hour
|
|
MTBF [year]
|
26 year
|
MTTR [hour]
|
2 hour
|
Availability
|
0.999999614
|
CPU
|
16-core, 2.0 GHz
|
SDRAM
|
16 G
|
Flash memory
|
128 MB
|
Power supply mode
|
DC
|
AC
|
|
HVDC
|
|
Rated input voltage [V]
|
DC: -48 V/-60 V
|
AC: 200 V to 240 V/100 V to 127 V dual live wires
|
|
HVDC: 240 V
|
|
Input voltage range [V]
|
DC: -48 V/-72 V
|
AC: 180 V to 264 V
|
|
HYDC: 188 Vdc to 290 Vdc
|
|
Maximum input current [A]
|
DC: 18 A
|
AC: 5.4 A
|
|
HVDC: 4.8 A
|
|
Maximum input cable size [mm²]
|
DC: 6mm^2. 4mm^2 (1-15 meters) recommended
|
AC: 1.5mm^2
|
|
Front-end circuit breaker/fuse [A]
|
DC: ≥20 A
|
AC: ≥6 A
|
|
HVDC: ≥6.3 A
|
|
Heat dissipation mode
|
Air cooling
|
Airflow direction
|
From left to right
|
Noise at normal temperature (acoustic power) [dB(A)]
|
< 72 dB (meeting the ETSI 72 dBA standard)
|
Number of slots
|
6
|
Number of service board slots
|
2
|
Switching capacity
|
1820 Gbit/s
|
Redundant MPUs
|
Fixed-configuration, not pluggable
|
Redundant network processing units
|
Fixed-configuration, not pluggable
|
Redundant power supply
|
1+1
|
Redundant fans
|
If a single fan fails, the system can still work for a short period of time at an ambient temperature of 40°C.
|
Long-term operating temperature [°C(°F)]
|
DC: -20°C(-4°F) to 65°C(149°F)
|
AC: 0°C(33.8°F) to 45°C(113°F)
|
|
Short-term operating temperature [°C(°F)]
|
AC:-5°C(23°F) to 55°C(131°F)
|
Restriction on the operating temperature variation rate [°C(°F)]
|
≤ 30°C/hour (54°F/hour)
|
Storage temperature [°C(°F)]
|
-40°C(-40°F) to 70°C(158°F)
|
Long-term operating relative humidity [RH]
|
5% RH to 90% RH, non-condensing
|
Short-term operating relative humidity [RH]
|
5% RH to 95% RH, non-condensing
|
Storage relative humidity [RH]
|
5% RH to 95% RH, non-condensing
|
Long-term operating altitude [m(ft.)]
|
≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature
of the device decreases by 1°C [33.8°F] each time the altitude increases by 220 m [721.78 ft.].) |
Storage altitude [m(ft.)]
|
< 5000 m(< 16404.2 ft.)
|
1.Table And Wide Supply Chain System
We have established a perfect supply chain system to provide a wide range of products with reliable quality and reasonable price.
2.Competitive Price
We ensure the most competitive price.Warm reminders here, telecommunications equipment configuration is quite different, the price show
3.Safe And Easy Payment Solutions
We support a variety of payment methods, such as T/T, credit card, et
4.Strong Pre-Sales And After-Sales Services
To provide customers with professional pre- sales service, as well as after-sales technical Services
5.More Than 20 Years Industry Experience
We have been engaged in this industry more than 20 years, we have rich industry experience.
6.Fast Delivery And Shipping
Fast, professional and reliable delivery.
Q: How about your main products?
A:Our product lines include Switches.Routers,OLTs,SDHs. Network Modules, Interface Cards, Security Firewalls, Wireless AP etc.
Email: Lilicheng0510@163.com