نحن نوفر للعملاء العديد من منتجات الاتصالات بأسعار معقولة ومنتجات وخدمات عالية الجودة
描述 | 零件编号 | 模型 | First Supported Version | Remarks |
---|---|---|---|---|
ME60-X8A Integrated Chassis DC Components | 02353MYQ | ME0B0BKP0874 | V800R012C00 | - |
Figure 1 Appearance of the ME60-X8A
Table 2 Technical specifications of the ME0B0BKP0874
物品 | 规格 |
---|---|
Cabinet installation standards | Can be installed in a standard 19" 800 mm-deep cabinet. A H w 2.2 m-high N68E cabinet is used by default. |
不含包装的尺寸(高 x 宽 x 深)[毫米(英寸)] | 930 mm x 442 mm x 650 mm (36.61 in. x 17.40 in. x 25.59 in.) (Chassis main body) 930 mm x 442 mm x 750 mm (36.61 in. x 17.40 in. x 29.53 in.) (Dimensions of the chassis body together with cable trays and front and back attachments) |
Chassis height [U] | 21 U |
Weight without packaging (full configuration) [kg(lb)] | [1T bundle] 209 kg (460.77 lb) |
Typical power consumption [W] | 4110 W (fully configured with BSUF-240s) 4770 W (fully configured with BSUF-480s) 6520 W (fully configured with BSUF-1Ts) |
Typical heat dissipation [BTU/hour] | 13334.6 BTU/hour (fully configured with BSUF-240s) 15475.9 BTU/hour (fully configured with BSUF-480s) 21153.6 BTU/hour (fully configured with BSUF-1Ts) |
MTBF [year] | 年36.23 |
MTTR [hour] | 0.5 hour |
Availability | 0.999998425 |
Power supply mode | DC built-in |
Maximum number of power chassis inputs | (8 channels/PEM)*2 PEM=(2 channels/PM)*4 PM*2 PEM=16 channels |
Rated input voltage [V] | –48 V/ –60 V |
Input voltage range [V] | –40 V to –72 V |
Maximum input current [A] | 63 A/single-module |
Maximum input cable diameter [mm²] | 毫米35 ²/channel |
Front-end circuit breaker/fuse [A] | [1T bundle] DC device: 6 PMs, with a total of 12 channels of 63 A |
Noise at normal temperature (acoustic power) [dB(A)] | NEBS-compliance (< 78 dBA @ 27°C (80.6°F)) |
Number of slots | 12 |
Number of service board slots | 8 |
Switching capacity | 25.16 Tbps BSUF-1T) |
Redundant MPUs | 1:1 |
Redundant Switch fabrics | 3+1 |
Redundant power supply | [1T bundle] 5+1 |
Redundant fans | [1T bundle] 3 assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) |
长期工作温度[°C(°F)] | 0°C 到 45°C (32°F 至 113°F) |
Short-term operating temperature [°C(°F)] | -5°C 到 55°C (23°F 至 131°F) |
Restriction on the operating temperature variation rate [°C(°F)] | <000000>le; 30°C/hour (86°F/hour) |
Storage temperature [°C(°F)] | -40°C 到 70°C (-40°F 至 158°F) |
长期工作相对湿度[RH] | 5% RH to 85% RH, non-condensing |
Short-term operating relative humidity [RH] | 5% RH 至 95% RH,无凝结 |
Storage relative humidity [RH] | 5% RH 至 95% RH,无凝结 |
Long-term operating altitude [m(ft.)] | <000000>le; 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].) |
Storage altitude [m(ft.)] | Less than 5000 m (16404 ft.) |
1. 平台化、宽广的供应链体系
我们建立了完善的供应链体系,提供种类繁多、质量可靠、价格合理的产品。
2.有竞争力的价格
我们保证最具竞争力的价格。温馨提示,电信设备配置差异较大,价格显示
3.安全便捷的支付解决方案
我们支持多种付款方式,如电汇、信用卡等
4.强大的售前和售后服务
为客户提供专业的售前服务,以及售后技术服务
5.超过20年的行业经验
我们从事这个行业已经20多年了,有丰富的行业经验。
6.快速送货和运输
送货快捷、专业、可靠。
问:你们的主要产品怎么样?
答:我们的产品线包括交换机、路由器、OLT、SDH。 网络模块、接口卡、安全防火墙、无线AP等。
البريد الإلكتروني:
Lilicheng0510@163.com
Flat/RM P ، 4/F ، Lladro Center ، 72 Hoi Yuen Road ، Kwun Tong ، Hong Kong ، China