نحن نوفر للعملاء العديد من منتجات الاتصالات بأسعار معقولة ومنتجات وخدمات عالية الجودة
| Article | Spécification |
|---|---|
| Cabinet installation standards | Can be installed in a standard 19" 800 mm-deep cabinet. A h w 2.2 m-high N68E cabinet is used by default. |
| Dimensions sans emballage (H x L x P) [mm(po)] | 175 mm x 442 mm x 650 mm (6.89 in. x 17.40 in. x 25.59 in.) |
| Chassis height [U] | 4 U |
| Weight without packaging (base configuration) [kg(lb)] | 15 kg (33.07 lb) |
| Weight without packaging (full configuration) [kg(lb)] | 42 kg (92.59 lb) |
| Consommation électrique typique [W] | 800 W (fully configured with BSUF-51s) 920 W (fully configured with BSUF-120s) 1239 W (fully configured with BSUF-241s) |
| Dissipation thermique typique [BTU/heure] | 2595.5 BTU/hour (fully configured with BSUF-51s) 2984.9 BTU/hour (fully configured with BSUF-120s) 4019.8 BTU/hour (fully configured with BSUF-241s) |
| MTBF [year] | année34.76 |
| MTTR [hour] | 0.5 hour |
| Availability | 0.999998358 |
| Power supply mode | DC built-in |
| Maximum number of power chassis inputs | (1 channel/PEM)*2 PEM=2 channels |
| Rated input voltage [V] | –48 V/ –60 V |
| Input voltage range [V] | –38.4 V to –72 V |
| Maximum input current [A] | 42 A/single-module |
| Maximum input cable diameter [mm²] | mm25 ² |
| Front-end circuit breaker/fuse [A] | 50 A |
| Noise at normal temperature (acoustic power) [dB(A)] | ETSI-compliance (<72dBA @ 23°C (73.4°F)) |
| Number of slots | 5 |
| Number of service board slots | 3 |
| Switching capacity | 1.08 tbps |
| Redundant MPUs | 1:1 |
| Redundant power supply | 1+1 |
| Redundant fans | Support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) |
| Température de fonctionnement à long terme [°C(°F)] | 0°C à 45°C (32°F à 113°F) |
| Température de fonctionnement à court terme [°C(°F)] | -5°C à 55°C (23°F à 131°F) |
| Restriction on the operating temperature variation rate [°C(°F)] | <000000>le; 30°C/hour (86°F/hour) |
| Storage temperature [°C(°F)] | -40°C à 70°C (-40°F à 158°F) |
| Long-term operating relative humidity [RH] | 5% RH to 85% RH, non-condensing |
| Short-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
| Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
| Long-term operating altitude [m(ft.)] | <000000>le; 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].) |
| Storage altitude [m(ft.)] | Less than 5000 m (16404 ft.) |
Q : Qu'en est-il de vos principaux produits ?
البريد الإلكتروني:
Lilicheng0510@163.com