CloudEngine S5735-L-Q Series Quiet Switches are compact all-gigabit switches designed for noise-sensitive service scenarios in a wide range of sectors, from Office Automation (OA) and education to healthcare.
Built on next generation, high-performance hardware and powered by Versatile Routing Platform (VRP), these switches offer flexible Ethernet networking, diversified security control, and support for multiple Layer 3 routing protocols — providing higher performance and more powerful service processing capabilities for networks. All switches in the series are fanless, quiet, and energy-efficient.
Item | Specification |
---|---|
Dimensions without packaging (H x W x D) [mm(in.)] |
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.) |
Chassis height [U] | 1 U |
Weight without packaging [kg(lb)] | 3.69 kg (8.14 lb) |
Weight with packaging [kg(lb)] | 4.45 kg (9.81 lb) |
Typical power consumption [W] | 30.8 W |
Typical heat dissipation [BTU/hour] | 105.09 BTU/hour |
Maximum power consumption [W] | 34 W |
Maximum heat dissipation [BTU/hour] | 116.01 BTU/hour |
MTBF [year] | 62.05 year |
MTTR [hour] | 2 hour |
Availability | >0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] | Noise-free (no fans), < 30 |
Noise at normal temperature (acoustic pressure) [dB(A)] | Noise-free (no fans), < 20 |
Number of card slots | 0 |
Number of power slots | 0 |
Number of fans modules | 0 |
Redundant power supply | Not supported |
Long-term operating temperature [°C(°F)] | –5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.51 ft.) |
Short-term operating temperature [°C(°F)] | Not supported |
Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). When the following optical modules are used, the device can operate in the temperature range of –5°C to +40°C (23°F to 104°F):
|
Q: How about your main products?
Email: Lilicheng0510@163.com