loading

We provide customers with various communication products at reasonable prices and high quality products and services

CloudEngine 8865-SAN-4CNEW 02355SDP With 4 Subcard Slots, Without Fan and Power Modules Gigabit Poe Switch 1
CloudEngine 8865-SAN-4CNEW 02355SDP With 4 Subcard Slots, Without Fan and Power Modules Gigabit Poe Switch 2
CloudEngine 8865-SAN-4CNEW 02355SDP With 4 Subcard Slots, Without Fan and Power Modules Gigabit Poe Switch 3
CloudEngine 8865-SAN-4CNEW 02355SDP With 4 Subcard Slots, Without Fan and Power Modules Gigabit Poe Switch 4
CloudEngine 8865-SAN-4CNEW 02355SDP With 4 Subcard Slots, Without Fan and Power Modules Gigabit Poe Switch 5
CloudEngine 8865-SAN-4CNEW 02355SDP With 4 Subcard Slots, Without Fan and Power Modules Gigabit Poe Switch 1
CloudEngine 8865-SAN-4CNEW 02355SDP With 4 Subcard Slots, Without Fan and Power Modules Gigabit Poe Switch 2
CloudEngine 8865-SAN-4CNEW 02355SDP With 4 Subcard Slots, Without Fan and Power Modules Gigabit Poe Switch 3
CloudEngine 8865-SAN-4CNEW 02355SDP With 4 Subcard Slots, Without Fan and Power Modules Gigabit Poe Switch 4
CloudEngine 8865-SAN-4CNEW 02355SDP With 4 Subcard Slots, Without Fan and Power Modules Gigabit Poe Switch 5

CloudEngine 8865-SAN-4CNEW 02355SDP With 4 Subcard Slots, Without Fan and Power Modules Gigabit Poe Switch

    oops...!

    no product data.

    Go to homepage
    Use
    other
    Place of Origin
    Guangdong, China
    Type
    Enterprise Switch
    Products Description

     

    CloudEngine 8865-SAN-4CNEW 02355SDP With 4 Subcard Slots, Without Fan and Power Modules gigabit poe switch
    Details Images
    CloudEngine 8865-SAN-4CNEW 02355SDP With 4 Subcard Slots, Without Fan and Power Modules Gigabit Poe Switch 6
    CloudEngine 8865-SAN-4CNEW 02355SDP With 4 Subcard Slots, Without Fan and Power Modules Gigabit Poe Switch 7
    Specification
    Other part numbers
    02355RTA (CE8865-4C Mainframe (With 4 Subcard Slots, Without Fan and Power Modules)) 02355RTB (CE8865-4C Mainframe (With 4 Subcard
    Slots, 2*AC Power Modules, 3*Fans, Port-side Intake)) 02356FKL (CE8865-4C mainframe with license bundle(With 4 Subcard Slots, 2*AC
    Power Modules, 3*Fans, Port-side Intake, Software license)) 02356FKP (CE8865-4C mainframe with license bundle(With 4 Subcard
    Slots, 2*AC Power Modules, 3*Fans, Port-side Exhaust, Software license))
    Installation Type
    Cabinet installation
    Depth [mm]
    600.0 mm
    Chassis height [U]
    2
    Wide [mm]
    442.0 mm
    Height [mm]
    88.1 mm
    Weight with packaging [kg(lb)]
    21.3 kg (46.96 lb) (with two power module filler panels and three fan module filler panels but no power modules, fan modules,
    cards, and card filler panels) 24.02 kg (52.96 lb) (with four card filler panels, two power module filler panels, and three fan
    module filler panels but no power modules, fan modules, and cards)
    Weight without packaging [kg(lb)]
    12.76 kg (28.13 lb) (with two power module filler panels and three fan module filler panels but no power modules, fan modules,
    cards, and card filler panels) 15.48 kg (34.13 lb) (with four card filler panels, two power module filler panels, and three fan
    module filler panels but no power modules, fan modules, and cards)
    Maximum power consumption [W]
    Configured with four CE88-D16CQ-H cards: - 888 W (100% traffic load, short-distance optical modules on 64 x 100GE ports, normal
    temperature, dual AC power modules) - 1318 W (100% traffic load, long-distance optical modules on 64 x 100GE ports, high
    temperature, dual AC power modules) - 1376 W (100% traffic load, long-distance optical modules on 48 x 100GE + 16 x 200GE ports,
    high temperature, dual AC power modules) Configured with four CE88-D10CQ-H cards: - 406 W (100% traffic load, short-distance
    optical modules on 40 x 100GE ports, normal temperature, dual AC power modules) - 549 W (100% traffic load, short-distance optical
    modules on 40 x 200GE ports, normal temperature, dual AC power modules) - 612 W (100% traffic load, long-distance optical modules
    on 40 x 100GE ports, high temperature, dual AC power modules) - 965 W (100% traffic load, long-distance optical modules on 40 x
    200GE ports, high temperature, dual AC power modules) Configured with four CE88-D8YS4DQ-H cards: - 531 W (100% traffic load,
    short-distance optical modules on 16 x 400GE + 32 x 25GE ports, normal temperature, dual AC power modules) - 830 W (100% traffic
    load, long-distance optical modules on 16 x 400GE + 32 x 25GE ports, high temperature, dual AC power modules) Configured with four
    CE88-D24YS2CQ-H cards: - 410 W (100% traffic load, short-distance optical modules on 96 x 25GE + 8 x 100GE ports, normal
    temperature, dual AC power modules) - 718 W (100% traffic load, long-distance optical modules on 96 x 25GE + 8 x 100GE ports, high
    temperature, dual AC power modules) Configured with four CE88-D24T2CQ-H cards: - 455 W (100% traffic load, short-distance optical
    modules on 96 x 10GE electrical + 8 x 100GE ports, normal temperature, dual AC power modules) - 732 W (100% traffic load,
    long-distance optical modules on 96 x 10GE electrical + 8 x 100GE ports, high temperature, dual AC power modules)
    Typical power consumption [W]
    Configured with four CE88-D16CQ-H cards: - 650 W (100% traffic load, copper cables on 32 x 100GE ports, normal temperature, dual
    AC power modules) - 728 W (100% traffic load, short-distance optical modules on 32 x 100GE ports, normal temperature, dual AC
    power modules) Configured with four CE88-D10CQ-H cards: - 315 W (100% traffic load, copper cables on 20 x 100GE ports, normal
    temperature, dual AC power modules) - 338 W (100% traffic load, copper cables on 20 x 200GE ports, normal temperature, dual AC
    power modules) - 345 W (100% traffic load, short-distance optical modules on 20 x 100GE ports, normal temperature, dual AC power
    modules) - 420 W (100% traffic load, short-distance optical modules on 20 x 200GE ports, normal temperature, dual AC power
    modules) Configured with four CE88-D8YS4DQ-H cards: - 306 W (100% traffic load, copper cables on 8 x 400GE + 16 x 25GE ports,
    normal temperature, dual AC power modules) - 406 W (100% traffic load, short-distance optical modules on 8 x 400GE + 16 x 25GE
    ports, normal temperature, dual AC power modules) Configured with four CE88-D24YS2CQ-H cards: - 305 W (100% traffic load, copper
    cables on 48 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules) - 338 W (100% traffic load, short-distance
    optical modules on 48 x 25GE + 4 x 100GE ports, normal temperature, dual AC power modules) Configured with four CE88-D24T2CQ-H
    cards: - 381 W (100% traffic load, copper cables on 48 x 10GE electrical + 4 x 100GE ports, normal temperature, dual AC power
    modules) - 388 W (100% traffic load, short-distance optical modules on 48 x 10GE electrical + 4 x 100GE ports, normal temperature,
    dual AC power modules)
    Static power consumption [W]
    Configured with four CE88-D16CQ-H cards: 569 W Configured with four CE88-D10CQ-H cards: 297 W Configured with four CE88-D8YS4DQ-H
    cards: 297 W Configured with four CE88-D24YS2CQ-H cards: 276 W Configured with four CE88-D24T2CQ-H cards: 330 W
    Heat dissipation mode
    Air cooling
    Maximum heat dissipation [BTU/hour]
    Configured with four CE88-D16CQ-H cards: - 3029.9 BTU/hour (100% traffic load, short-distance optical modules on 64 x 100GE ports,
    normal temperature, dual AC power modules) - 4497 BTU/hour (100% traffic load, long-distance optical modules on 64 x 100GE ports,
    high temperature, dual AC power modules) - 4694.9 BTU/hour (100% traffic load, long-distance optical modules on 48 x 100GE + 16 x
    200GE ports, high temperature, dual AC power modules) Configured with four CE88-D10CQ-H cards: - 1385.3 BTU/hour (100% traffic
    load, short-distance optical modules on 40 x 100GE ports, normal temperature, dual AC power modules) - 1873.2 BTU/hour (100%
    traffic load, short-distance optical modules on 40 x 200GE ports, normal temperature, dual AC power modules) - 2088.1 BTU/hour
    (100% traffic load, long-distance optical modules on 40 x 100GE ports, high temperature, dual AC power modules) - 3292.6 BTU/hour
    (100% traffic load, long-distance optical modules on 40 x 200GE ports, high temperature, dual AC power modules) Configured with
    four CE88-D8YS4DQ-H cards: - 1811.8 BTU/hour (100% traffic load, short-distance optical modules on 16 x 400GE + 32 x 25GE ports,
    normal temperature, dual AC power modules) - 2832 BTU/hour (100% traffic load, long-distance optical modules on 16 x 400GE + 32 x
    25GE ports, high temperature, dual AC power modules) Configured with four CE88-D24YS2CQ-H cards: - 1398.9 BTU/hour (100% traffic
    load, short-distance optical modules on 96 x 25GE + 8 x 100GE ports, normal temperature, dual AC power modules) - 2449.8 BTU/hour
    (100% traffic load, long-distance optical modules on 96 x 25GE + 8 x 100GE ports, high temperature, dual AC power modules)
    Configured with four CE88-D24T2CQ-H cards: - 1552.5 BTU/hour (100% traffic load, short-distance optical modules on 96 x 10GE
    electrical ports + 8 x 100GE ports, normal temperature, dual AC power modules) - 2497.6 BTU/hour (100% traffic load, long-distance
    optical modules on 96 x 10GE electrical ports + 8 x 100GE ports, high temperature, dual AC power modules)
    Typical heat dissipation [BTU/hour]
    Configured with four CE88-D16CQ-H cards: - 2217.8 BTU/hour (100% traffic load, copper cables on 32 x 100GE ports, normal
    temperature, dual AC power modules) - 2483.9 BTU/hour (100% traffic load, short-distance optical modules on 32 x 100GE ports,
    normal temperature, dual AC power modules) Configured with four CE88-D10CQ-H cards: - 1074.8 BTU/hour (100% traffic load, copper
    cables on 20 x 100GE ports, normal temperature, dual AC power modules) - 1153.3 BTU/hour (100% traffic load, copper cables on 20 x
    200GE ports, normal temperature, dual AC power modules) - 1177.1 BTU/hour (100% traffic load, short-distance optical modules on 20
    x 100GE ports, normal temperature, dual AC power modules) - 1433 BTU/hour (100% traffic load, short-distance optical modules on 20
    x 200GE ports, normal temperature, dual AC power modules) Configured with four CE88-D8YS4DQ-H cards: - 1044.1 BTU/hour (100%
    traffic load, copper cables on 8 x 400GE + 16 x 25GE ports, normal temperature, dual AC power modules) - 1385.3 BTU/hour (100%
    traffic load, short-distance optical modules on 8 x 400GE + 16 x 25GE ports, normal temperature, dual AC power modules) Configured
    with four CE88-D24YS2CQ-H cards: - 1040.7 BTU/hour (100% traffic load, copper cables on 48 x 25GE + 4 x 100GE ports, normal
    temperature, dual AC power modules) - 1153.3 BTU/hour (100% traffic load, short-distance optical modules on 48 x 25GE + 4 x 100GE
    ports, normal temperature, dual AC power modules) Configured with four CE88-D24T2CQ-H cards: - 1300 BTU/hour (100% traffic load,
    copper cables on 48 x 10GE electrical + 4 x 100GE ports, normal temperature, dual AC power modules) - 1323.9 BTU/hour (100%
    traffic load, short-distance optical modules on 48 x 10GE electrical + 4 x 100GE ports, normal temperature, dual AC power modules)
    Static heat dissipation [BTU/hour]
    Configured with four CE88-D16CQ-H cards: 1941.4 BTU/hour Configured with four CE88-D10CQ-H cards: 1013.4 BTU/hour Configured with
    four CE88-D8YS4DQ-H cards: 1013.4 BTU/hour Configured with four CE88-D24YS2CQ-H cards: 941.7 BTU/hour Configured with four
    CE88-D24T2CQ-H cards: 1126 BTU/hour
    Power supply mode
    AC,DC,HVDC
    Rated input voltage [V]
    - 2000 W AC&240 V DC power module: AC: 100 V AC to 240 V AC, 50/60 Hz; DC: 240 V DC - 1800 W AC&240 V DC power module: AC: 100 V
    AC to 240 V AC, 50/60 Hz; DC: 240 V DC - 2000 W high-voltage DC power module: 336 V DC - 2200 W DC power module: –48 V DC to –60 V
    DC; +48 V DC
    Input voltage range [V]
    - 2000 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 66 Hz; DC: 190 V DC to 290 V DC - 1800 W AC&240 V DC power
    module: AC: 90 V AC to 290 V AC, 45 Hz to 66 Hz; DC: 190 V DC to 290 V DC - 2000 W high-voltage DC power module: 260 V DC to 400 V
    DC - 2200 W DC power module: –38.4 V DC to –72 V DC; +38.4 V DC to +57 V DC
    Maximum input current [A]
    - 2000 W AC&240 V DC power module: 10 A (100 V AC to 240 V AC); 10 A (240 V DC) - 1800 W AC&240 V DC power module: 10 A (100 V AC
    to 240 V AC); 10 A (240 V DC) - 2000 W high-voltage DC power module: 10 A (336 V DC) - 2200 W DC power module: 63 A (–48 V DC to
    –60 V DC); 63 A (+48 V DC)
    Rated output power [W]
    - 2000 W AC&240 V DC power module: 2000 W (220 V AC to 240 V AC&240 V DC), 1800 W (200 V AC to 220 V AC), 900 W (100 V AC to 130 V
    AC) - 1800 W AC&240 V DC power module: 1800 W (200 V AC to 240 V AC&240 V DC), 900 W (100 V AC to 130 V AC) - 2000 W high-voltage
    DC power module: 2000 W - 2200 W DC power module: 2200 W
    Memory
    DRAM: 8 GB
    NOR Flash
    64 MB x 2
    SSD Flash
    4GB SSD
    USB
    It can be used for log backup and USB-based deployment. This function is reserved.
    Console port
    RJ45
    Downlink Service interface
    For details, see the port description of each card.
    Uplink Service interface
    For details, see the port description of each card.
    Service port supporting the stack function
    Reserved function. This function is not enabled.
    RTC
    Supported
    Switching capacity [bps,bit/s]
    To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel.
    Redundant fans
    The device supports 2+1 backup of fan modules that work in hot standby mode. The system can operate normally for a short time
    after a single fan module fails. You are advised to replace the faulty fan module immediately.
    Redundant power supply
    1+1 backup
    Number of power modules
    2
    Power supply surge protection
    - AC: 6 kV in common mode and 6 kV in differential mode - HVDC: 4 kV in common mode and 2 kV in differential mode - DC: 4 kV in
    common mode and 2 kV in differential mode
    Types of fans
    Pluggable
    Number of fans
    3
    Airflow direction
    Port-side air intake or port-side air exhaust, depending on the fan modules and power modules that are used. The fan modules and
    power modules must have the same airflow direction.
    Storage temperature [°C(°F)]
    -40ºC to +70ºC (-40°F to +158°F)
    Long-term operating temperature [°C(°F)]
    0°C to 40°C (32°F to 104°F) at an altitude of 0–1800 m (0–5906 ft.) Note: When the altitude is 1800–5000 m (5096–16404 ft.), the
    highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
    Storage relative humidity [RH]
    5% to 95% RH, non-condensing
    Long-term operating relative humidity [RH]
    5% RH to 95% RH, non-condensing
    Storage altitude [m(ft.)]
    ≤ 5000 m (16404 ft.)
    Long-term operating altitude [m(ft.)]
    ≤ 5000 m (16404 ft.)
    MTBF [year]
    48.4 years
    MTTR [hour]
    1.86 hours
    Noise at high temperature (40°C, sound pressure)
    Port-side air intake: < 86.1 dB(A) Port-side air exhaust: < 87.9 dB(A)
    Noise at normal temperature (27°C, sound pressure)
    Port-side air intake: < 64.3 dB(A) Port-side air exhaust: < 65.2 dB(A)
    Availability
    0.9999964621

    Why Choose Us

    1.Table And Wide Supply Chain System
    We have established a perfect supply chain system to provide a wide range of products with reliable quality and reasonable price.

    2.Competitive Price

    We ensure the most competitive price.Warm reminders here, telecommunications equipment configuration is quite different, the price show

    3.Safe And Easy Payment Solutions

    We support a variety of payment methods, such as T/T, credit card, et

    4.Strong Pre-Sales And After-Sales Services

    To provide customers with professional pre- sales service, as well as after-sales technical Services

    5.More Than 20 Years Industry Experience

    We have been engaged in this industry more than 20 years, we have rich industry experience.

    6.Fast Delivery And Shipping

    Fast, professional and reliable delivery.

    FAQ

    Q: How about your main products?
    A:Our product lines include Switches.Routers,OLTs,SDHs. Network Modules, Interface Cards, Security Firewalls, Wireless AP etc.


    Q: What brand of products do you offer?
    A:We are devoted to offering Huawei, ZTE, Cisco, Ruijie and other network equipment brands

    Q:Can we get free samples?
    A: Sorry, it is not available, but you can pay for one.

    Q: What trade terms do you use ?
    A: We offer EXW.FOB,CIF and CNF or as your request.

    Q: How about your delivery time?
    A:Generally, it will take 1 to 10 days after receiving your deposit. The specific delivery time depends on the items and the quantity of your order.

    Q: Do you test all your goods?
    A:Yes we have professional engineer to test all devices before shipping.
    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs
    Related Products
    no data
    Tel: +86 18328719811

    We provide customers with various communication products at reasonable prices and high quality products and services

    Contact with us
    Contact person: Dou Mao
    WhatsApp: +86 18328719811
    Add: 

    Flat/Rm P, 4/F, Lladro Centre, 72 Hoi Yuen Road, Kwun Tong, Hong Kong, China

    Copyright © 2025 Intelligent Network INT Limited  | Sitemap | Privacy Policy
    Customer service
    detect