Description | Part Number | Model | First Supported Version | Remarks |
---|---|---|---|---|
NE40E-X16A Integrated AC Chassis Components(Including 4 Fan Tray) | 02359915 | CR5B0BKP1674 | V800R006C20 | - |
Figure 1 Appearance of the CR5B0BKP1674
Item | Specification |
---|---|
Cabinet installation standards | Can be installed in a standard 19" 800 mm-deep cabinet. A H w 2.2 m-high N68E cabinet is used by default. |
Dimensions without packaging (H x W x D) [mm(in.)] |
1778 mm x 442 mm x 650 mm (70.00 in. x 17.40 in. x 25.59 in.) (Chassis main body) 1778 mm x 442 mm x 750 mm (70.00 in. x 17.40 in. x 29.53 in.) (Dimensions of the chassis body together with cable trays and front and back attachments) |
Chassis height [U] | 40 U |
Weight without packaging (base configuration) [kg(lb)] | 133.3 kg (293.93 lb) |
Weight without packaging (full configuration) [kg(lb)] |
[400G bundle] 350.7 kg (773.29 lb) [1T bundle] 395.1 kg (871.2 lb) |
Typical power consumption [W] |
7720 W (fully configured with LPUF-240s) 9040 W (fully configured with LPUF-480s) 12390 W (fully configured with LPUI-1Ts) |
Typical heat dissipation [BTU/hour] |
25046.9 BTU/hour (fully configured with LPUF-240s) 29329.6 BTU/hour (fully configured with LPUF-480s) 40198.4 BTU/hour (fully configured with LPUI-1Ts) |
MTBF [year] | 22.33 year |
MTTR [hour] | 0.5 hour |
Availability | 0.9999974444 |
Power supply mode | AC built-in |
Maximum number of power chassis inputs | (4 channels/PEM)*4 PEM=(1 channels/PM)*4 PM*4 PEM=16 channels |
Rated input voltage [V] | 200 V to 240 V |
Input voltage range [V] | 180 V to 264 V |
Maximum input current [A] | 16 A/single-module |
Maximum input cable diameter [mm²] | Standard C19 cable |
Front-end circuit breaker/fuse [A] |
16 A/single-module [400G bundle] AC device: 10 PMs, with a total of 10 channels of 16 A [1T bundle] AC device: 14 PMs, with a total of 14 channels of 16 A |
Noise at normal temperature (acoustic power) [dB(A)] | NEBS-compliance (< 78 dBA @ 27°C (80.6°F)) |
Number of slots | 22 |
Number of service board slots | 16 |
Switching capacity | 50.32Tbps(LPUI-1T) |
Redundant MPUs | 1:1 |
Redundant Switch fabrics | 3+1 |
Redundant power supply |
[400G bundle] 5+5 [1T bundle] 7+1 |
Redundant fans |
[400G bundle] 2 partitions; 2 assemblies/partition; each partition in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) [1T bundle] 2 partitions; 3 assemblies/partition; each partition in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) |
Long-term operating temperature [°C(°F)] | 0°C to 45°C (32°F to 113°F) |
Short-term operating temperature [°C(°F)] | -5°C to 55°C (23°F to 131°F) |
Restriction on the operating temperature variation rate [°C(°F)] | ≤ 30°C/hour (86°F/hour) |
Storage temperature [°C(°F)] | -40°C to 70°C (-40°F to 158°F) |
Long-term operating relative humidity [RH] | 5% RH to 85% RH, non-condensing |
Short-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | ≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].) |
Storage altitude [m(ft.)] | Less than 5000 m (16404 ft.) |
Q: How about your main products?