Description | Part Number | Model | First Supported Version | Remarks |
---|---|---|---|---|
NE40E-X16A Integrated HVDC Chassis Components(2T,Including 6 Fan Tray) | 02351PJR | CR5B0BKP1678 | V800R010C00 | - |
Figure 1 Appearance of the NE40E-X16A
Item | Specification |
---|---|
Cabinet installation standards | Can be installed in a standard 19" 1000 mm-deep cabinet, part number is 02115109(CR5B0N610E60) |
Dimensions without packaging (H x W x D) [mm(in.)] | 1778 mm x 442 mm x 946 mm (70.00 in. x 17.40 in. x 37.24 in.) (Dimensions of the chassis body together with cable trays and front and back attachments) |
Chassis height [U] | 40 U |
Weight without packaging (base configuration) [kg(lb)] | 176.1 kg (302.69 lb) |
Weight without packaging (full configuration) [kg(lb)] | [2T bundle] 453.3kg (999.34 lb) |
Typical power consumption [W] |
9040 W (fully configured with LPUF-480s) 12390 W (fully configured with LPUI-1Ts) 22450 W(fully configured with LPUI-2Ts) |
Typical heat dissipation [BTU/hour] |
29329.6 BTU/hour (fully configured with LPUF-480s) 40198.4 BTU/hour (fully configured with LPUI-1Ts) 72837.2 BTU/hour (fully configured with LPUI-2Ts) |
MTBF [year] | 22.33 year |
MTTR [hour] | 0.5 hour |
Availability | 0.9999974444 |
Power supply mode | HVDC built-in |
Maximum number of power chassis inputs | (4 channels/PEM)*4 PEMs = (1 channel/PM)*4 PMs*4 PEMs = 16 channels |
Rated input voltage [V] | 240V/380V |
Input voltage range [V] | 192 to 288V,264 to 400V |
Maximum input current [A] | 14 A/single-module |
Maximum input cable diameter [mm²] | 2.5 mm² |
Front-end circuit breaker/fuse [A] |
14A/single-module [2T bundle] HVDC device: 16 PMs, with a total of 16 channels of 14 A |
Noise at normal temperature (acoustic power) [dB(A)] | NEBS-compliance (< 78 dBA @ 27°C (80.6°F)) |
Number of slots | 22 |
Number of service board slots | 16 |
Switching capacity | 81.92Tbps(LPUI-2T) |
Redundant MPUs | 1:1 |
Redundant Switch fabrics | 3+1 |
Redundant power supply | [2T bundle] 9+1 |
Redundant fans | [2T bundle] 2 partitions; 3 assemblies/partition; each partition in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) |
Long-term operating temperature [°C(°F)] | 0°C to 45°C (32°F to 113°F) |
Short-term operating temperature [°C(°F)] | -5°C to 55°C (23°F to 131°F) |
Restriction on the operating temperature variation rate [°C(°F)] | ≤ 30°C/hour (86°F/hour) |
Storage temperature [°C(°F)] | -40°C to 70°C (-40°F to 158°F) |
Long-term operating relative humidity [RH] | 5% RH to 85% RH, non-condensing |
Short-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | ≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].) |
Storage altitude [m(ft.)] | Less than 5000 m (16404 ft.) |
1.Table And Wide Supply Chain System
We have established a perfect supply chain system to provide a wide range of products with reliable quality and reasonable price.
2.Competitive Price
We ensure the most competitive price.Warm reminders here, telecommunications equipment configuration is quite different, the price show
3.Safe And Easy Payment Solutions
We support a variety of payment methods, such as T/T, credit card, et
4.Strong Pre-Sales And After-Sales Services
To provide customers with professional pre- sales service, as well as after-sales technical Services
5.More Than 20 Years Industry Experience
We have been engaged in this industry more than 20 years, we have rich industry experience.
6.Fast Delivery And Shipping
Fast, professional and reliable delivery.
Q: How about your main products?
A:Our product lines include Switches.Routers,OLTs,SDHs. Network Modules, Interface Cards, Security Firewalls, Wireless AP etc.
Email: Lilicheng0510@163.com