Brindamos a los clientes varios productos de comunicación a precios razonables y productos y servicios de alta calidad.
Part Number
|
02354WBC
|
Modelis
|
CE6860-HAM
|
Apraksts
|
CE6860-HAM switch (48*25GE SFP28, 8*100GE QSFP28, 2*AC power modules, 4*fan modules, port-side exhaust)
|
Other part numbers
|
02354WBA (CE6860-HAM switch (48*25G SFP28, 8*100G QSFP28, without fan and power modules)) 02354WBB (CE6860-HAM switch (48*25GE
SFP28, 8*100GE QSFP28, 2*AC power modules, 4*fan modules, port-side intake)) |
Installation Type
|
Cabinet installation
|
Depth [mm]
|
420 mm
|
Chassis height [U]
|
1 |
Wide [mm]
|
442 mm
|
Height [mm]
|
43.6 mm
|
Weight with packaging [kg(lb)]
|
11.9 kg (26.24 lb)
|
Weight without packaging [kg(lb)]
|
6.7 kg (14.8 lb) (excluding optical modules, power modules, and fan modules)
|
Maximum power consumption [W]
|
- 48 x 50G + 8 x 200G: 619 W (100% throughput, downlink 2 W 50G optical modules, uplink 6.5 W 200G optical modules, 40°C, dual
power modules) - 48 x 25G + 8 x 100G: 544 W (100% throughput, downlink 1.5 W 25G optical modules, uplink 5 W 100G optical modules, 40°C, dual power modules) |
Typical power consumption [W]
|
- 48 x 50G + 8 x 200G: 374 W (50% throughput, copper cables on all ports, normal temperature, dual power modules) - 48 x 25G + 8 x
100G: 360 W (50% throughput, copper cables on all ports, normal temperature, dual power modules), 407 W (50% throughput, short-distance optical modules on all ports, normal temperature, dual power modules) |
Static power consumption [W]
|
322 W
|
Heat dissipation mode
|
Air cooling
|
Maximum heat dissipation [BTU/hour]
|
- 48 x 50G + 8 x 200G: 2110 BTU/hour (100% throughput, downlink 2 W 50G optical modules, uplink 6.5 W 200G optical modules, 40°C,
dual power modules) - 48 x 25G + 8 x 100G: 1858 BTU/hour (100% throughput, downlink 1.5 W 25G optical modules, uplink 5 W 100G optical modules, 40°C, dual power modules) |
Typical heat dissipation [BTU/hour]
|
- 48 x 50G + 8 x 200G: 1277 BTU/hour (50% throughput, copper cables on all ports, normal temperature, dual power modules) - 48 x
25G + 8 x 100G: 1229 BTU/hour (50% throughput, copper cables on all ports, normal temperature, dual power supplies), 1389 BTU/hour (50% throughput, short-distance optical modules on all ports, normal temperature, dual power modules) |
Static heat dissipation [BTU/hour]
|
1100 BTU/hour
|
Power supply mode
|
AC,DC,HVDC
|
Rated input voltage [V]
|
- 600 W AC&240 V DC power module: 100 V AC to 240 V AC, 50/60 Hz; 240 V DC - 1000 W DC power module: –48 V DC to –60 V DC - 1200 W
high-voltage DC power module: 240 V DC to 380 V DC |
Input voltage range [V]
|
- 600 W AC&240 V DC power module: 90 V AC to 290 V AC, 45 Hz to 65 Hz; 190 V DC to 290 V DC - 1000 W DC power module: –38.4 V DC
uz –72 V DC - 1200 W high-voltage DC power module: 190 V DC to 400 V DC |
Maximum input current [A]
|
- 600 W AC&240 V DC power module: 8 A (100 V AC to 240 V AC); 4 A (240 V DC) - 1000 W DC power module: 30 A (–48 V DC to –60 V DC)
- 1200 W high-voltage DC power module: 8 A |
Rated output power [W]
|
- 600 W AC&240 V DC power module: 600 W - 1000 W DC power module: 1000 W - 1200 W high-voltage DC power module: 1200 W
|
Memory
|
DRAM: 8 GB
|
NOR Flash
|
64 MB
|
NAND Flash
|
4 GB
|
USB
|
It can be used for log backup and USB-based deployment. This function is reserved.
|
Console port
|
RJ45
|
Downlink Service interface
|
48 x 25GE SFP28/48 x 50GE SFP56 1. 25GE ports can be used as 10GE ports. 50GE ports can be used as 25GE ports but not 10GE or GE
ports. 2. When 25GE ports are upgraded to 50GE ports, eight ports form a group. Note: 1. Support for optical modules: (1) In the case of port-side air intake, downlink ports support 10G-AOC/SR/LR/ER/ZR and 25G-AOC/SR/LR. (2) In the case of port-side air exhaust, downlink ports support 10G-AOC/SR/LR and 25G-AOC/SR/LR. 2. Support for copper cables: When 50GE copper cables are used, contact Huawei engineers for interconnection verification. |
Uplink Service interface
|
8 x 100GE QSFP28/8 x 200GE QSFP56 1. Each 100GE port can be configured as a 40GE port, and each 200GE port can be configured as a
100GE/40GE port. 2. When 100GE ports are upgraded to 200GE, four such ports form a group. 3. 100GE ports are divided into groups 1 to 4 and 5 to 8. Four ports in each group are split together. Ports 2, 4, 6, and 8 can be split into four 25GE ports (whose speeds can be set to 10 Gbit/s). After the split, ports 1, 3, 5, and 7 cannot be used. A 100GE port cannot be split into 2 x 50GE (50GE: 2 x 25GE) ports. 4. 200GE ports cannot be split. Note: 1. Support for optical modules: (1) In the case of port-side air intake, 100GE/200GE ports support 100G-AOC/SR4/CWDM4/LR4/4WDM. (2) In the case of port-side air exhaust, 100GE/200GE ports support 100G-AOC/SR4/CWDM4/LR4 optical modules, but do not support 50GE and 200GE optical modules. 2. Support for copper cables: When 200GE copper cables are used, contact Huawei engineers for interconnection verification. |
Service port supporting the stack function
|
Reserved function. This function is not enabled.
|
RTC
|
Supported
|
Switching capacity [bps,bit/s]
|
To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel.
|
Redundant fans
|
The device supports 3+1 backup of fan modules that work in hot standby mode. The system can operate properly for a short period of
time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Redundant power supply
|
1+1 backup
|
Number of power modules
|
2 |
Power supply surge protection
|
- AC power supply protection: 6 kV in common mode and 6 kV in differential mode - 240 V HVDC power protection: 4 kV in common mode
and 2 kV in differential mode - –48 V DC power supply protection: 4 kV in common mode and 2 kV in differential mode - 380 V HVDC power protection: 4 kV in common mode and 2 kV in differential mode |
Types of fans
|
Pluggable
|
Number of fans
|
4 |
Airflow direction
|
Port-side air intake or port-side air exhaust, depending on the fan modules and power modules that are used. The fan modules and
power modules must have the same airflow direction. |
Storage temperature [°C(°F)]
|
-40ºC to +70ºC (-40°F to +158°F)
|
Long-term operating temperature [°C(°F)]
|
0°C to 40°C (32°F līdz 104°F) at an altitude of 0–1800 m (0–5906 ft.) Note: When the altitude is 1800–5000 m (5096–16404 ft.), the
highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage relative humidity [RH]
|
5% to 95% RH, non-condensing
|
Long-term operating relative humidity [RH]
|
5% RH to 95% RH, non-condensing
|
Storage altitude [m(ft.)]
|
<000000>le; 5000 m (16404 ft.)
|
Long-term operating altitude [m(ft.)]
|
<000000>le; 5000 m (16404 ft.)
|
MTBF [year]
|
30.32 gadiem
|
MTTR [hour]
|
1.5 stundas
|
Noise at high temperature (40°C, sound pressure)
|
Front-to-back airflow: 67.6 dB(A) on average (maximum: 73.4 dB(A)) Back-to-front airflow: 68 dB(A) on average (maximum: 75.4
dB(A)) |
Noise at normal temperature (27°C, sound pressure)
|
Front-to-back airflow: 49.8 dB(A) on average (maximum: 53.6 dB(A)) Back-to-front airflow: 47.8 dB(A) on average (maximum: 51.2
dB(A)) |
Availability
|
0.9999943515
|
1.Table And Wide Supply Chain System
We have established a perfect supply chain system to provide a wide range of products with reliable quality and reasonable price.
2.Competitive Price
We ensure the most competitive price.Warm reminders here, telecommunications equipment configuration is quite different, the price show
3.Safe And Easy Payment Solutions
We support a variety of payment methods, such as T/T, credit card, et
4.Strong Pre-Sales And After-Sales Services
To provide customers with professional pre- sales service, as well as after-sales technical Services
5.More Than 20 Years Industry Experience
We have been engaged in this industry more than 20 years, we have rich industry experience.
6.Fast Delivery And Shipping
Fast, professional and reliable delivery.
Q: How about your main products?
A:Our product lines include Switches.Routers,OLTs,SDHs. Network Modules, Interface Cards, Security Firewalls, Wireless AP etc.
Correo electrónico:
Lilicheng0510@163.com
Flat/Rm P, 4/F, Lladro Center, 72 Hoi Yuen Road, Kwun Tong, Hong Kong, China