Cabinet installation standards
|
Can be installed in a standard 19" 800 mm-deep cabinet. A 2.2 m-high N68E cabinet is used by default.
|
Dimensions without packaging (H x W x D) [mm(in.)]
|
930 mm x 442 mm x 650 mm (36.61 in. x 17.40 in. x 25.59 in.) (Chassis main body)
930 mm x 442 mm x 750 mm (36.61 in. x 17.40 in. x 29.53 in.) (Dimensions of the chassis body together with cable trays and front and back attachments)
|
Chassis height [U]
|
21 U
|
Weight without packaging (base configuration) [kg(lb)]
|
74.5 kg (164.24 lb)
|
Weight without packaging (full configuration) [kg(lb)]
|
[1T bundle] 206.5 kg (455.25 lb)
|
Typical power consumption [W]
|
4110 W (fully configured with BSUF-240s)
4770 W (fully configured with BSUF-480s)
6520 W (fully configured with BSUF-1Ts)
|
Typical heat dissipation [BTU/hour]
|
13334.6 BTU/hour (fully configured with BSUF-240s)
15475.9 BTU/hour (fully configured with BSUF-480s)
21153.6 BTU/hour (fully configured with BSUF-1Ts)
|
MTBF [year]
|
36.23 år
|
MTTR [hour]
|
0.5 hour
|
Availability
|
0.999998425
|
Power supply mode
|
AC/HVDC built-in
|
Maximum number of power chassis inputs
|
(4 channels/PEM)*2 PEM=(1 channel/PM)*4 PM*2 PEM=8 channels
|
Rated input voltage [V]
|
AC:200 V to 240 V
HVDC:240 V/380 V
|
Input voltage range [V]
|
AC:180 V to 264 V
HVDC:192 V to 288 V,264 V to 400 V
|
Maximum input current [A]
|
AC:16 A/single-module
HVDC:14 A/single-module
|
Maximum input cable diameter [mm²]
|
AC:Standard C19 cable
HVDC:2.5 mm² |
Front-end circuit breaker/fuse [A]
|
AC:
[1T bundle] AC device: 8 PMs, with a total of 8 channels of 16 A
HVDC:
[1T bundle] HVDC device: 8 PMs, with a total of 8 channels of 14 A
|
Noise at normal temperature (acoustic power) [dB(A)]
|
NEBS-compliance (< 78 dBA @ 27°C (80.6°F))
|
Number of slots
|
12
|
Number of service board slots
|
8 |
Switching capacity
|
25.16 Tbps (BSUF-1T)
|
Redundant MPUs
|
1:1
|
Redundant Switch fabrics
|
3+1
|
Redundant power supply
|
[1T bundle] 4+1
|
Redundant fans
|
[1T bundle] 3 assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F)
|
Long-term operating temperature [°C(°F)]
|
0°C til 45°C (32°F to 113°F)
|
Short-term operating temperature [°C(°F)]
|
-5°C til 55°C (23°F to 131°F)
|
Restriction on the operating temperature variation rate [°C(°F)]
|
<000000>le; 30°C/hour (86°F/hour)
|
Storage temperature [°C(°F)]
|
-40°C til 70°C (-40°F to 158°F)
|
Long-term operating relative humidity [RH]
|
5% RH to 85% RH, non-condensing
|
Short-term operating relative humidity [RH]
|
5% RH to 95% RH, non-condensing
|
Storage relative humidity [RH]
|
5% RH to 95% RH, non-condensing
|
Long-term operating altitude [m(ft.)]
|
<000000>le; 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].)
|
Storage altitude [m(ft.)]
|
Less than 5000 m (16404 ft.)
|