43.2 mm × 536 mm × 900 mm (1.70 in. x 21.10 in. x 35.43 in.)
• Maximum net weight (not configured with 12 NVMe drives): 16 kg (35.27 lb)
• Maximum weight (configured with 12 NVMe drives): 16.9 kg (37.26 lb)
• Packing material weight: 8.7 kg (19.18 lb)
Height: 1 U; width: 533.4 mm (21 in.); depth: 900 mm (35.43 in.)
2 x third-generation Intel® Xeon® Scalable processors (Ice Lake)
Each processor integrates a memory controller, supporting eight memory channels.
Built-in PCIe controller, supporting PCIe 4.0 and 64 lanes per processor
3-socket UltraPath Interconnect (UPI) bus interconnection with up to 11.2 GT/S transmission speed per bus
Up to 38 cores
UP to 3.0 GHz
Min. 1.5 MB L3 cache per core
Up to 300 W TDP
32 x memory module slots
Up to 32 x DDR4 DIMMs
The memory module type can be either RDIMM or LRDIMM.
Max. 3200 MT/s memory speed
Mixed use of DIMMs with a same type but two different capacities is supported (install the DIMMs with large capacity in primary channels and the DIMMs with small capacity in secondary channels and ensure DIMMs are fully configured or symmetrically installed along CPUs).
Up to 16 PMem memory modules.
The PMem modules must be used with the DDR4 DIMMs, and each channel supports only one PMem module.
The PMem modules work in the AD mode or MM mode.
Max. 3200 MT/s memory speed
PMem modules of different specifications (capacity and rank) cannot be used together.
(Optional) 1 x 2.5″ SAS/SATA drive or 12 x 2.5″ NVMe drives
25GE dual-NIC or SDI V3 NIC for each node
1 x 48 V to 12 V PSU, with a rated power of 1600 W
1 x PowerButton indicator/button, 1 x health indicator, and 1 x UID indicator/button
Air cooling: 5 fan modules (non-NVME scenarios) or 7 fan modules (12-NVMe scenarios)
Built-in BMC chip on the mainboard
Operating temperature: 5°C to 40°C (41°F to 104°F) (ASHRAE Classes A1 to A3 compliant)
Storage temperature (within three months): –30°C to +60°C (–22°F to +140°F)
Storage temperature (within one year): –10°C to +35°C (14°F to 95°F)
Maximum temperature change rate: 20°C (36°F) per hour, 5°C (9°F) per 15 minutes
Note: When a single fan is faulty, the maximum operating temperature is 5°C (9°F) lower than the rated value.
Empty water inside the equipment for long-term storage.
Operating temperature: 8% to 90%
Storage humidity (within three months): 8% to 85%
Storage humidity (within six months): 8% to 80%
Storage humidity (within one year): 20% to 75%
Maximum change rate: 20% per hour
≤ 3050 m (10,006.56 ft)
When the configuration complies with ASHRAE Class A1 and A2, and the operating altitude is above 900 m (2952.76 ft), the operating temperature decreases by 1°C (1.8°F) for every increase of 300 m (984.25 ft).
When the server configuration complies with ASHRAE Class A3 standards and the altitude is above 900 m (2,952.76 ft), the operating temperature decreases by 1°C (1.8°F) for every increase of 175 m (574.15 ft).
SP385 NIC, SP583 NIC, SP382 NIC, SP682 NIC, FBGF-NIC-R1S2 NIC and SDI V3 NIC
Port on the front panel: 1 x RJ45 management port
Port on the rear panel: 1 x high-speed signal port, 1 x power socket, and 1 x liquid-cooling port
Built-in port: 1 x SATA drive port