Cabinet installation standard
|
A66E
|
||
|
Wide [mm]
|
442 mm
|
||
|
Depth [mm]
|
515.5 mm
|
||
|
Height [mm]
|
575 mm
|
||
|
Chassis height [U]
|
13
|
||
|
Weight without packaging [kg(lb)]
|
48.94 (107.89)
|
||
|
Maximum power consumption [W]
|
2914
|
||
|
Maximum heat dissipation [BTU/hour]
|
9942.98
|
||
|
Heat dissipation mode
|
Absorbing cold air into the device
|
||
|
Power supply mode
|
Built-in AC
|
||
|
Rated input voltage [V]
|
- AC input: 110 V AC/220 V AC, 50/60 Hz
|
||
|
- High-voltage DC input: 240 V DC
|
|||
|
Input voltage range [V]
|
- AC input: 90–290 V AC; 45–65 Hz (When the input voltage ranges from 90 V AC to 176 V AC, the maximum output power is 1500 W.
When the input voltage ranges from 176 V AC to 200 V AC, the maximum output power is 2300 W. If the input voltage ranges from 200 V AC to 290 V AC, the maximum output power is 2500 W.) |
||
|
- High-voltage DC input: 190 V DC to 290 V DC (When the input voltage ranges from 190 V DC to 200 V DC, the maximum output power
is 2300 W. When the input voltage ranges from 200 V DC to 290 V DC, the maximum output power is 2500 W.) |
|||
|
Number of slots
|
10
|
||
|
Number of service board slots
|
8
|
||
|
Number of MPU slots
|
2
|
||
|
Redundant MPUs
|
The control and switching units work in 1:1 hot backup mode.
|
||
|
Redundant power supply
|
Single-input power supply system: N+1 backup
|
||
|
Redundant fans
|
Fan modules support hot backup. If a fan module is faulty, the system can still work properly for a short period of time. However,
you are advised to replace the faulty fan module immediately. |
||
|
Number of power modules
|
6
|
||
|
Number of fan modules
|
2
|
||
|
Types of fans
|
Pluggable
|
||
|
Noise at normal temperature (acoustic power) [dB(A)]
|
- ≤69.0dB(A) @AC 2500 W N+N power supply
|
||
|
- ≤ 78.0 dB(A)@AC 2500 W N+1 power supply
|
|||
|
- ≤ 78.0 dB(A)@AC 2500 W N+0 power supply
|
|||
|
note: The current version does not support N+N configuration of AC power modules.
|
|||
|
Airflow direction
|
Front-to-back
|
||
|
Long-term operating temperature [°C(°F)]
|
-5°C to 45°C (23°F to 113°F) at an altitude of -60 m to 1800 m (-197 ft. to 5906 ft.)
|
||
|
Storage temperature [°C(°F)]
|
–40°C to +70°C (–40°F to +158°F)
|
||
|
Long-term operating relative humidity [RH]
|
5% RH to 95% RH (noncondensing)
|
||
|
Long-term operating altitude [m(ft.)]
|
–60 m to +5000 m (–197 ft. to +16404 ft.)
|
||
|
Storage altitude [m(ft.)]
|
< 5000 m (16404.00 ft.)
|
||
|
MTBF [year]
|
30.65
|
||
|
MTTR [hour]
|
2.42
|
||
|
Availability
|
0.999995403
|
||
Email: Lilicheng0510@163.com