Item
|
Specification
|
Cabinet installation standards
|
Can be installed in a 1000 mm-deep standard 19-inch cabinet and is installed in a 2200 mm-high HW N610E cabinet by default.
|
Dimensions without packaging (H x W x D) [mm(in.)]
|
1778 mm x 442 mm x 650 mm (70 in. x 17.4 in. x 25.59 in.)
|
Chassis height [U]
|
40 U
|
Weight without packaging [kg(lb)]
|
148 kg (326.28 lb)
|
Weight without packaging (full configuration) [kg(lb)]
|
1T single-chassis (full configuration): 376 kg (828.94 lb)
|
|
2T cluster (full configuration): 434 kg (956.81 lb)
|
Typical power consumption (with configuration) [W]
|
1T single-chassis:12300 W
|
|
2T single-chassis:19100 W
|
Typical heat dissipation (with configuration) [BTU/hour]
|
1T single-chassis:39906.4 BTU/hour
|
|
2T single-chassis:61968.4 BTU/hour
|
MTBF [year]
|
12.20 year
|
MTTR [hour]
|
0.5 hour
|
Availability
|
0.99999
|
Power supply mode
|
AC/HVDC built-in
|
Maximum number of power chassis inputs
|
(4 channels/PEM) x 4 PEM=(1 channel/PM) x 4 PM x 4 PEM=16 channels
|
Rated input voltage [V]
|
AC: 200 V to 240 V
|
|
HVDC: 240 V/380 V
|
Input voltage range [V]
|
AC:
|
|
Voltage range:180 V to 264 V
|
|
220 V rated voltage:200 V to 240 V
|
|
HVDC:
|
|
192 V to 400 V
|
Maximum input current [A]
|
AC:16A/single-module
|
|
HVDC:14A/single-module
|
Maximum input cable size [mm²]
|
AC: Standard C19 cable
|
|
HVDC: 2.5 mm²
|
Front-end circuit breaker/fuse [A]
|
AC:16 A/single-module
|
|
HVDC:
|
|
14 A/single-module
|
|
[1T bundle]HVDC device: 14 PMs, in need of 14 channels of 14A
|
|
[2T bundle]HVDC device: 16 PMs, in need of 16 channels of 14A
|
Noise at normal temperature (acoustic power) [dB(A)]
|
Complies with the NEBS standard (< 78 dB(A) @ 27°C).
|
Number of slots
|
22
|
Number of service board slots
|
16
|
Switching capacity
|
81.92 Tbit/s
|
Redundant MPUs
|
1:01
|
Redundant Switch fabrics
|
3+1
|
Redundant power supply
|
N+N
|
Redundant fans
|
Consists of upper and lower areas.
|
|
Three fan modules. If a single fan fails, the system can still work for a short period of time at an ambient temperature of 40°C.
|
Long-term operating temperature [°C(°F)]
|
0°C to 40°C(32°F to 104°F)
|
Short-term operating temperature [°C(°F)]
|
-5°C to 50°C (23°F to 122°F)
|
Restriction on the operating temperature variation rate [°C(°F)]
|
≤ 30°C/hour (54°F/hour)
|
Storage temperature [°C(°F)]
|
–40°C to +70°C (–40°F to +158 °F)
|
Long-term operating relative humidity [RH]
|
5% RH to 85% RH, non-condensing
|
Short-term operating relative humidity [RH]
|
5% RH to 95% RH, non-condensing
|
Storage relative humidity [RH]
|
5% RH to 95% RH, non-condensing
|
Long-term operating altitude [m(ft.)]
|
3000M @ 40°C
|
Storage altitude [m(ft.)]
|
Less than 5000 m (16404 ft.)
|
Email: Lilicheng0510@163.com