The NetEngine 20E-S series is suitable for enterprise networks of various types and scales. proprietary Network Processing (NP) chips , and packed with innovative technologies — such as Internet Protocol (IP) hard pipe, IP Flow Performance Measurement (FPM), and Bidirectional Forwarding Detection (BFD) — NetEngine 20E-S routers provide high performance transmission, high-quality private line services, and accurate fault detection and location. With 99.999% reliability achieved through comprehensive hardware and software reliability technologies, a Software-Defined Networking (SDN) architecture enables balanced traffic distribution, improving network bandwidth utilization. And with an operating temperate spanning –40ºC to 65ºC, the NetEngine 20E-S series is designed to withstand even the harshest environments.
| Description | Part Number | Model | First Supported Version | Remarks |
|---|---|---|---|---|
| NE20E-S2F Integrated Chassis Components | 02350BUP | CR2B0BKP0211 | V800R007C00 | - |
| Item | Specification |
|---|---|
| Cabinet installation standards | ETSI 21-inch; IEC 19-inch |
| Dimensions without packaging (H x W x D) [mm(in.)] | 88.1 mm x 442 mm x 220 mm (3.47 in. x 17.4 in. x 8.66 in.) |
| Chassis height [U] | 2 U |
| Weight without packaging (base configuration) [kg(lb)] | 8.1 kg (17.86 lb) |
| Weight without packaging (full configuration) [kg(lb)] |
DC: 9.5 kg (20.95 lb) AC: 10.5 kg (23.15 lb) |
| Typical power consumption [W] |
DC: 309 W AC: 335 W |
| Typical heat dissipation [BTU/hour] |
DC: 1002.5 BTU/hour AC: 1086.9 BTU/hour |
| MTBF [year] | 37 year |
| MTTR [hour] | 2 hour |
| Availability | 0.999999614 |
| CPU | 8-core 1.5GHz |
| SDRAM | 8 G |
| Flash memory | 32 MB |
| Power supply mode | DC,AC,HVDC |
| Rated input voltage [V] |
DC: -48 V/-60 V AC: 200 V to 240 V/100 V to 127 V dual live wires HVDC: 240 V |
| Input voltage range [V] |
DC: -48 V/-72 V AC: 180 V to 264 V HYDC: 188 Vdc to 290 Vdc |
| Maximum input current [A] |
DC: 10.5 A AC: 2.8 A HVDC: 4.8 A |
| Maximum input cable diameter [mm²] |
DC: 6mm^2. 4mm^2 (1-30 meters) recommended AC: 1.5mm^2 |
| Front-end circuit breaker/fuse [A] |
DC: ≥16 A AC: ≥3 A HVDC: ≥6.3 A |
| Heat dissipation | Air cooling |
| Airflow direction | left-to-right direction |
| Noise at normal temperature (acoustic power) [dB(A)] | < 72 dB (meeting the ETSI 72 dBA standard) |
| Number of slots | 6 |
| Number of service board slots | 2 |
| Switching capacity | 320 Gbps |
| Redundant MPUs | Fixed-configuration, not pluggable |
| Redundant network processing units | Fixed-configuration, not pluggable |
| Redundant power supply | 1+1 |
| Redundant fans | If a single fan fails, the system can still work for a short period of time at an ambient temperature of 40°C. |
| Long-term operating temperature [°C(°F)] |
DC: -5°C(23°F) to 65°C(149°F) AC: 0°C(33.8°F) to 45°C(113°F) |
| Short-term operating temperature [°C(°F)] | AC:-5°C(23°F) to 55°C(131°F) |
| Enhanced operating temperature [°C(°F)] | - |
| Restriction on the operating temperature variation rate [°C(°F)] | ≤ 30°C/hour(54°F/hour) |
| Storage temperature [°C(°F)] | -40°C(-40°F) to 70°C(158°F) |
| Long-term operating relative humidity [RH] | 5% RH to 90% RH, non-condensing |
| Short-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
| Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
| Long-term operating altitude [m(ft.)] | <= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].) |
| Storage altitude [m(ft.)] | < 5000 m(< 16404.2 ft.) |
Q: How about your main products?