Trade Information
● Model No.:S5731-S48S4X-A
● Chair size:43.6*442*220mm
● Material: metal plastic
● Place of Origin: Guangdong, China
● Place of use: LACP, QoS, SNMP, Stackable, VLAN Support
● PoE: Not Supported
● Warranty: 1years
● MOQ: 1 pieces
Introduction
Detailed description
| Item | Specification |
|---|---|
| Dimensions without packaging (H x W x D) [mm(in.)] |
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.40 in. x 8.66 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.40 in. x 8.94 in.) |
| Dimensions with packaging (H x W x D) [mm(in.)] | 90.0 mm x 550.0 mm x 355.0 mm (3.54 in. x 21.65 in. x 13.98 in.) |
| Chassis height [U] | 1 U |
| Chassis material | Metal |
| Weight without packaging [kg(lb)] | 3.49 kg (7.69 lb) |
| Weight with packaging [kg(lb)] | 4.85 kg (10.69 lb) |
| Typical power consumption [W] | 87.89 W |
| Typical heat dissipation [BTU/hour] | 299.89 BTU/hour |
| Maximum power consumption [W] | 121.04 W |
| Maximum heat dissipation [BTU/hour] | 413.00 BTU/hour |
| Static power consumption [W] | 47.28 W |
| MTBF [years] | 31.39 years |
| Availability | > 0.99999 |
| Noise at normal temperature (acoustic power) [dB(A)] | 41.42 dB(A) |
| Noise at normal temperature (acoustic pressure) [dB(A)] | 27.74 dB(A) |
| Number of card slots | 0 |
| Number of power slots | 0 |
| Number of fans modules | 2 |
| Redundant power supply | Not supported |
| Long-term operating temperature [°C(°F)] | -5°C to +45°C (23°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.) |
| Short-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) |
| Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met:
If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur. Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation cannot exceed 10 km. |
| Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
| Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
| Long-term operating altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
| Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
| Power supply mode | AC built-in |
| Rated input voltage [V] | - AC input: 100 V AC to 240 V AC, 50/60 Hz |
| Input voltage range [V] | - AC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz |
| Maximum input current [A] | 3 A |
| Memory | 2 GB |
| Flash memory | The physical space is 1 GB. You can run the display version command to view the actual available space. |
| Console port | RJ45 |
| Eth Management port | RJ45 |
| USB | Not supported |
| RTC | Supported |
| RPS input | Not supported |
| Service port surge protection [kV] | - |
| Power supply surge protection [kV] | ±6 kV in differential mode; ±6 kV in common mode |
| Ingress protection level (dustproof/waterproof) | IP20 |
| Types of fans | Built-in |
| Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment |
| Airflow direction | Air intake from left and front, air exhaustion from right |
| PoE | Not supported |
| Certification |
EMC certification Safety certification Manufacturing certification |
Email: Lilicheng0510@163.com