Typical power consumption[W]
We provide customers with various communication products at reasonable prices and high quality products and services
Trade Information
● Model No.: S5735-L24T4S-A1
● Chair size:43.6*220*420mm
● Material: metal plastic
● Place of Origin: Guangdong, China
● Place of use: LACP, QoS, SNMP, Stackable, VLAN Support
● PoE: Not Supported
● Warranty: 1years
● MOQ: 1 pieces
Introduction
Detailed description
|
Typical power consumption[W]
|
32.7
|
|
Heat dissipation mode
|
Heat dissipation with fan, intelligent fan speed adjustment
|
|
Maximum heat dissipation[BTU/hour]
|
162.42
|
|
Power supply mode
|
AC built-in
|
|
Input voltage range[V]
|
- AC input: 90 V AC to 264 V AC; 47 Hz to 63 Hz
- High-voltage DC input: 88 V DC to 300 V DC |
|
Rated input voltage[V]
|
- AC input: 100 V AC to 240 V AC; 50/60 Hz
- High-voltage DC input: 110 V DC to 250 V DC |
|
Maximum input current[A]
|
2 A
|
|
Number of power slots
|
0
|
|
Number of card slots
|
0
|
|
Memory
|
512 MB
|
|
Flash memory
|
512 MB
|
|
Redundant power supply
|
Not supported
|
|
Types of fans
|
Built-in
|
|
Noise at normal temperature (acoustic power)[dB(A)]
|
39
|
|
Noise at normal temperature (acoustic pressure)[dB(A)]
|
27.2
|
|
Airflow direction
|
Air intake from left and front, air exhaustion from right
|
|
Storage temperature[°C(°F)]
|
-40°C to +70°C (-40°F to +158°F)
|
|
Long-term operating temperature[°C(°F)]
|
-5°C to +50°C (23°F to 122°F) (0 m to 1800 m altitude, non-industrial optical modules)
-5°C to +55°C (23°F to 131°F) (0 m to 1800 m altitude, industrial optical modules with transmission distances less than or equal to 10 km) |
|
Restriction on the operating temperature variation rate[°C(°F)]
|
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
The switch cannot be started when the ambient temperature is lower than 0°C (32°F). The operating temperature ranges from -5°C to +45°C (23°F to 113°F) when optical modules with transmission distances greater than or equal to 70 km are used. |
|
Long-term operating relative humidity[RH]
|
5% to 95%, noncondensing
|
|
Storage altitude[m(ft.)]
|
0-5000 m (0-16404 ft.)
|
|
Long-term operating altitude[m(ft.)]
|
0-5000 m (0-16404 ft.)
|
|
MTBF[year]
|
66.16
|
|
MTTR[hour]
|
2
|
|
Availability
|
> 0.99999
|
|
Maximum number of physical ports on the entire device
|
28
|
|
Maximum number of 100GE ports
|
0
|
|
Maximum number of 40GE ports
|
0
|
|
Maximum number of 25GE ports
|
0
|
|
Maximum number of 10GE ports
|
0
|
|
Maximum number of GE ports
|
28
|
|
Maximum number of FE ports
|
28
|
|
1000M optical interface
|
4
|
|
1000M electrical interface
|
24
|
|
USB
|
Not supported
|
|
Console port
|
RJ45
|
|
Eth Management port
|
Not supported
|
|
Service port surge protection[kV]
|
Common mode: ±7 kV
|
|
Power supply surge protection
|
±6 kV in differential mode, ±6 kV in common mode
|
|
RPS input
|
Not supported
|
|
PoE
|
Not supported
|
Email: Lilicheng0510@163.com
Flat/Rm P, 4/F, Lladro Centre, 72 Hoi Yuen Road, Kwun Tong, Hong Kong, China