Technical Specifications
We provide customers with various communication products at reasonable prices and high quality products and services
Trade Information
● Model No.: S5735-L24T4X-QA1
● Chair size:43.6*220*442mm
● Material: metal plastic
● Place of Origin: Guangdong, China
● Place of use: LACP, QoS, SNMP, Stackable, VLAN Support
● PoE: Not Supported
● Warranty: 1years
● MOQ: 1 pieces
Introduction
Detailed description
|
Technical Specifications
|
|
|
Chassis material
|
Metal
|
|
Height[mm]
|
43.6 mm
|
|
Depth[mm]
|
220.0 mm
|
|
Wide[mm]
|
442.0 mm
|
|
Weight with packaging[kg(lb)]
|
4.45 (9.81)
|
|
Typical power consumption[W]
|
30.8
|
|
Typical heat dissipation[BTU/hour]
|
105.09
|
|
Input voltage range[V]
|
AC input: 90 V AC to 290 V AC, 45 Hz to 65 Hz
|
|
Rated input voltage[V]
|
AC input: 100 V AC to 240 V AC, 50/60 Hz
|
|
Maximum input current[A]
|
2 A
|
|
Number of power slots
|
0
|
|
Number of card slots
|
0
|
|
Memory
|
512 MB
|
|
Flash memory
|
512 MB
|
|
Redundant power supply
|
Not supported
|
|
Types of fans
|
None
|
|
Noise at normal temperature (acoustic power)[dB(A)]
|
Noise-free (no fans), < 30
|
|
Noise at normal temperature (acoustic pressure)[dB(A)]
|
Noise-free (no fans), < 20
|
|
Airflow direction
|
-
|
|
Storage temperature[°C(°F)]
|
-40°C to +70°C (-40°F to +158°F)
|
|
Long-term operating temperature[°C(°F)]
|
–5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.51 ft.)
|
|
Restriction on the operating temperature variation rate[°C(°F)]
|
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
Devices cannot start when the temperature is lower than 0°C (32°F). When the following optical modules are used, the device can operate in the temperature range of –5°C to +40°C (23°F to 104°F): - 10GE non-industrial optical module with a transmission distance of 10 km - Non-industrial FE/GE optical module with a transmission distance of 40 km or 80 km |
|
Long-term operating relative humidity[RH]
|
5% RH to 95% RH, non-condensing
|
|
Storage altitude[m(ft.)]
|
0-5000 m (0-16404 ft.)
|
|
Long-term operating altitude[m(ft.)]
|
0-5000 m (0-16404 ft.)
|
|
MTBF[year]
|
62.05
|
|
MTTR[hour]
|
2
|
|
Availability
|
> 0.99999
|
|
Maximum number of physical ports on the entire device
|
28
|
|
Maximum number of 100GE ports
|
0
|
|
Maximum number of 40GE ports
|
0
|
|
Maximum number of 25GE ports
|
0
|
|
Maximum number of 10GE ports
|
4
|
|
Maximum number of GE ports
|
28
|
|
Maximum number of FE ports
|
24
|
|
10GE optical interface
|
4
|
|
1000M electrical interface
|
24
|
|
USB
|
Supported
|
|
Console port
|
RJ45
|
|
Eth Management port
|
Not supported
|
|
Service port surge protection[kV]
|
Common mode: ±7 kV
|
|
Power supply surge protection
|
±6 kV in differential mode, ±6 kV in common mode
|
|
RPS input
|
Not supported
|
|
PoE
|
Not supported
|