Trade Information
● Model No.: S5735-L48T4S-A
● Chair size:43.6*220*420mm
● Material: metal plastic
● Place of Origin: Guangdong, China
● Place of use: LACP, QoS, SNMP, Stackable, VLAN Support
● PoE: Not Supported
● Warranty: 1years
● MOQ: 1 pieces
Introduction
Detailed description
| Chassis material | Metal |
| Height[mm] | 43.6 mm |
| Depth[mm] | 220.0 mm |
| Wide[mm] | 442.0 mm |
| Chassis height[U] | 1 |
| Weight with packaging[kg(lb)] | 4.42 |
| Maximum power consumption[W] | 53 |
| Typical power consumption[W] | 37 |
| Heat dissipation mode | Heat dissipation with fan, intelligent fan speed adjustment |
| Maximum heat dissipation[BTU/hour] | 180.8 |
| Typical heat dissipation[BTU/hour] | 126.25 |
| Power supply mode | AC built-in |
| Input voltage range[V] | - AC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz |
| - High-Voltage DC input: 190 V DC to 290 V DC | |
| Rated input voltage[V] | - AC input: 100 V AC to 240 V AC, 50/60 Hz |
| - High-Voltage DC input: 240 V DC | |
| Maximum input current[A] | 2 A |
| Number of power slots | 0 |
| Number of card slots | 0 |
| Memory | 1 GB |
| Flash memory | 512 MB in total. To view the available flash memory size, run the display version command. |
| Redundant power supply | Not supported |
| Types of fans | Built-in |
| Noise at normal temperature (acoustic power)[dB(A)] | 53.3 |
| Noise at normal temperature (acoustic pressure)[dB(A)] | 38.5 |
| Airflow direction | Air intake from left and front, air exhaustion from right |
| Storage temperature[°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
| Short-term operating temperature[°C(°F)] | -5°C to +55°C (23°F to 131°F) at an altitude of 0-1800 m (0-5906 ft.) |
| Long-term operating temperature[°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.) |
| Restriction on the operating temperature variation rate[°C(°F)] | When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
| The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met: | |
| - The equipment operates at a temperature of over 50°C (122°F) consecutively for at most 96 hours in one year. | |
| - The equipment operates at a temperature of over 50°C (122°F) for a total of no more than 360 hours in one year. | |
| - The equipment operates at a temperature of over 50°C (122°F) for no more in 15 times in one year. | |
| The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded. | |
| The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km. | |
| Long-term operating relative humidity[RH] | 5% RH to 95% RH, non-condensing |
| Storage altitude[m(ft.)] | 0-5000 m (0-16404 ft.) |
| Long-term operating altitude[m(ft.)] | 0-5000 m (0-16404 ft.) |
| MTBF[year] | 46.36 |
| MTTR[hour] | 2 |
| Availability | > 0.99999 |
| Maximum number of physical ports on the entire device | 52 |
| Maximum number of 100GE ports | 0 |
| Maximum number of 40GE ports | 0 |
| Maximum number of 25GE ports | 0 |
| Maximum number of 10GE ports | 0 |
| Maximum number of GE ports | 52 |
| Maximum number of FE ports | 48 |
| 1000M optical interface | 4 |
| 1000M electrical interface | 48 |
| USB | Supported |
| Console port | RJ45 |
| Eth Management port | RJ45 |
| Service port surge protection[kV] | Common mode: ±7 kV |
| Power supply surge protection | ±6 kV in differential mode, ±6 kV in common mode |
| RPS input | Not supported |
| PoE | Not supported |