The Huawei S5755-S24T8Y is a 24 port gigabit layer 3 access switch in the S5755-S series, designed specifically for high-density campus access and small aggregation in the Wi Fi 6/7 era. It features high bandwidth uplink, full port security, and flexible expansion, making it suitable for high-quality campus networks in industries such as government, finance, manufacturing, and healthcare

● Model No.:S5755-S24T8Y

● Size:145.0 mm x 650.0 mm x 550.0 mm 

● Port details: 24*10/100/1000 BASE-T ports, 8*25GE SFP28 ports, without power module 

● Place of Origin: Guangdong, China

● exchange capacity:2.4 Tbps / 24 Tbps 

●cooling method:Smart plug-in fan, supporting speed adjustment and alarm, suitable for high-temperature environments up to 50°CSmart plug-in fan, supporting speed adjustment and alarm, suitable for high-temperature environments up to 50°C

● Warranty: 1years

● MOQ: 1 pieces

5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Application scenarios

    1. Access and aggregation of medium and large industrial parks/enterprise office areas

    2. High density Wi Fi 6/7 AP deployment scenarios (such as shopping malls, hotels, and office buildings)

    3. Network construction with high requirements for bandwidth and security in factories, hospitals, campuses, etc

    4. Small data center edge access, carrying IoT devices and core business interconnection

    1 (178)
    2 (155)

    Introduction

    1. Full scenario high-density access with 24 gigabit electrical ports to meet wired access for PCs, servers, and terminals; 8 × 25GE 10 Gigabit uplink port, compatible with 10G/2.5G, easily achieving bottleneck free uplink core, suitable for Wi Fi 6/7 AP high-density aggregation and high traffic business.

    2. End to end secure encryption with full port support for MACsec, achieving encryption from the link layer to the access layer, ensuring data transmission privacy and integrity, suitable for government, enterprise, and financial scenarios with high security requirements.

    3. Full stack intelligence and virtualization have built-in features such as application recognition, business portability, VXLAN, etc., supporting network virtualization and multi business integration, reducing deployment and operation costs, and can be used as core devices for small parks or access/aggregation devices for medium to large parks.

    4. High reliability design supports 1+1 power redundancy, intelligent fans, and stable hardware architecture, ensuring long-term operation without downtime and adapting to 7 × 24-hour business scenarios

    Detailed description

    ItemSpecification
    Dimensions without packaging (H x W x D) [mm(in.)]

    Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.)

    Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 454.0 mm (1.72 in. x 17.4 in. x 17.87 in.)

    Dimensions with packaging (H x W x D) [mm(in.)]145.0 mm x 650.0 mm x 550.0 mm (5.71 in. x 25.59 in. x 21.65 in.)
    Chassis height [U]1 U
    Chassis materialMetal
    Weight without packaging [kg(lb)]5.08 kg (11.20 lb)
    Weight with packaging [kg(lb)]6.83 kg (15.06 lb)
    Typical power consumption [W]

    30% traffic under the ATIS standard, dual power modules:

    • 46 W (all ports used, two 80 W AC power modules)
    • 43 W (all ports used, two 240 W DC power modules)
    Typical heat dissipation [BTU/hour]

    30% traffic under the ATIS standard, dual power modules:

    • 156.95 (all ports used, two 80 W AC power modules)
    • 146.72 (all ports used, two 240 W DC power modules)
    Maximum power consumption [W]

    100% traffic under the ATIS standard, dual power modules:

    • 48 W (all ports used, two 80 W AC power modules)
    • 45 W (all ports used, two 240 W DC power modules)
    Maximum heat dissipation [BTU/hour]

    100% traffic under the ATIS standard, dual power modules:

    • 163.78 (all ports used, two 80 W AC power modules)
    • 153.54 (all ports used, two 240 W DC power modules)
    Static power consumption [W]21 W
    MTBF [years]129.56 years
    Availability> 0.99999
    Noise at normal temperature (acoustic power) [dB(A)]50.7 dBA
    Noise at normal temperature (acoustic pressure) [dB(A)]37.0 dBA
    Number of power slots2
    Number of fans modules2
    Redundant power supply

    1+1

    Pluggable AC and DC power modules can be used together on the same device.

    NOTE:

    Power modules with fans and power modules without fans cannot be installed on the same device.

    Long-term operating temperature [°C(°F)]–5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.44 ft.)
    Short-term operating temperature [°C(°F)]-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.)
    Restriction on the operating temperature variation rate [°C(°F)]

    When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

    The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met:

    • The operating temperature exceeds 45°C (113°F) for a maximum of 96 consecutive hours in a year.
    • The total time when the operating temperature exceeds 45°C (113°F) in a year is less than or equal to 360 hours.
    • The number of times the operating temperature exceeds 45°C (113°F) is less than or equal to 15 in one year.

    If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur.

    Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation at 50°C (122°F) cannot exceed 10 km.

    Storage temperature [°C(°F)]–40°C to +70°C (–40°F to +158°F)
    Long-term operating relative humidity [RH]5% RH to 95% RH, non-condensing
    Long-term operating altitude [m(ft.)]0–5000 m (0–16404 ft.)
    Storage altitude [m(ft.)]0-5000 m (0-16404 ft.)
    Power supply modePluggable power supply
    Rated input voltage [V]
    • AC input: 100 V AC to 130 V AC, 200 V AC to 240 V AC; 50/60 Hz
    • High-voltage DC input: 240 V DC
    • DC input: –48 V DC to –60 V DC
    Input voltage range [V]
    • AC input: 90 V AC to 290 V AC; 45 Hz to 66 Hz
    • High-voltage DC input: 190 V DC to 290 V DC
    • DC input: -38.4 V DC to -72 V DC
    Maximum input current [A]The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules.
    Memory4 GB
    Flash memoryPhysical space: 1 GB
    Console portRJ45
    Eth Management portRJ45
    USBSupported
    RTCSupported
    RPS inputNot supported
    Power supply surge protection [kV]
    • Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode
    • Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode
    Ingress protection level (dustproof/waterproof)IP20
    Types of fansBuilt-in
    Heat dissipation modeAir cooling for heat dissipation, intelligent fan speed adjustment
    Airflow directionAir intake from front, air exhaustion from rear (front-to-rear)
    PoENot supported
    Certification

    EMC certification

    Safety certification

    Manufacturing certification

    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
    Related Products
    Tel: +86 18328719811

    We provide customers with various communication products at reasonable prices and high quality products and services

    Contact with us
    Contact person: Dou Mao
    WhatsApp: +86 18328719811
    Add: 

    Flat/Rm P, 4/F, Lladro Centre, 72 Hoi Yuen Road, Kwun Tong, Hong Kong, China

    Copyright © 2026 Intelligent Network INT Limited  | Sitemap | Privacy Policy
    Product Lives
    Customer service