● Model No.:S5755-S48T8Y
● Size:145.0 mm x 650.0 mm x 550.0 mm
● Port details: 48*10/100/1000 BASE-T ports, 8*25GE SFP28 ports, without power module
● Place of Origin: Guangdong, China
● exchange capacity:496 Gbps / 740 Gbps
●security features:Intelligent speed regulating fan, supporting hot swapping
● Warranty: 1years
● MOQ: 1 pieces
Application scenarios
1. Medium to large enterprises/parks: As an access layer, it gathers a large number of wired terminals, with 25GE upstream to the aggregation/core, suitable for fully wireless office scenarios.
2. Education/Medical/Hotel: High density ports meet the requirements for classroom/ward/guest room terminal access, ensuring stable forwarding and guaranteeing business experience.
3. Enterprise branches/parks: Balancing access and lightweight core functions, simplifying network architecture.
Introduction
1. High density access and flexible uplink: 48 gigabit electrical ports meet the access needs of a large number of terminals such as office PCs, IP phones, printers, etc; 8 25GE SFP28 uplink, with sufficient bandwidth, suitable for Wi Fi 6/7 APs and high concurrency services.
2. Stable forwarding performance: 340Mpps line speed forwarding, non blocking transmission, ensuring smooth operation of high-definition video, cloud desktop, large file transfer and other businesses.
3. High reliability design: 1+1 power redundancy, fan redundancy, support stacking/link aggregation/VBST, reduce single point of failure risk, and ensure business continuity.
4. Intelligent operation and security: supports iPCA network quality perception, telemetry, and Netstream traffic analysis; Full port adaptation of security policies such as MACsec, NAC, ACL, etc., to strengthen network boundaries.
5. Network virtualization: Supports VxLAN, EVPN, and SRv6 to achieve campus network virtualization, multi service integration, and reduce deployment and operation costs.
6. Unified management: Supports CLI, Web, SNMP, NETCONF, compatible with Huawei iMaster NCE unified management platform, simplifies operation and maintenance
Detailed description
| Item | Specification |
|---|---|
| Dimensions without packaging (H x W x D) [mm(in.)] |
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 454.0 mm (1.72 in. x 17.4 in. x 17.87 in.) |
| Dimensions with packaging (H x W x D) [mm(in.)] | 145.0 mm x 650.0 mm x 550.0 mm (5.71 in. x 25.59 in. x 21.65 in.) |
| Chassis height [U] | 1 U |
| Chassis material | Metal |
| Weight without packaging [kg(lb)] | 5.20 kg (11.46 lb) |
| Weight with packaging [kg(lb)] | 7.61 kg (16.78 lb) |
| Typical power consumption [W] |
30% traffic under the ATIS standard, dual power modules:
|
| Typical heat dissipation [BTU/hour] |
30% traffic under the ATIS standard, dual power modules:
|
| Maximum power consumption [W] |
100% traffic under the ATIS standard, dual power modules:
|
| Maximum heat dissipation [BTU/hour] |
100% traffic under the ATIS standard, dual power modules:
|
| Static power consumption [W] | 24 W |
| MTBF [years] | 113.80 years |
| Availability | > 0.99999 |
| Noise at normal temperature (acoustic power) [dB(A)] | 50.7 dBA |
| Noise at normal temperature (acoustic pressure) [dB(A)] | 37.0 dBA |
| Number of power slots | 2 |
| Number of fans modules | 2 |
| Redundant power supply |
1+1 Pluggable AC and DC power modules can be used together on the same device. NOTE:
Power modules with fans and power modules without fans cannot be installed on the same device. |
| Long-term operating temperature [°C(°F)] | –5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.44 ft.) |
| Short-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) |
| Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met:
If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur. Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation at 50°C (122°F) cannot exceed 10 km. |
| Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) |
| Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
| Long-term operating altitude [m(ft.)] | 0–5000 m (0–16404 ft.) |
| Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) |
| Power supply mode | Pluggable power supply |
| Rated input voltage [V] |
|
| Input voltage range [V] |
|
| Maximum input current [A] | The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules. |
| Memory | 4 GB |
| Flash memory | Physical space: 1 GB |
| Console port | RJ45 |
| Eth Management port | RJ45 |
| USB | Supported |
| RTC | Supported |
| RPS input | Not supported |
| Power supply surge protection [kV] |
|
| Ingress protection level (dustproof/waterproof) | IP20 |
| Types of fans | Built-in |
| Heat dissipation mode | Air cooling for heat dissipation, intelligent fan speed adjustment |
| Airflow direction | Air intake from front and right and air exhaust from rear |
| PoE | Not supported |
| Certification |
EMC certification Safety certification Manufacturing certification |
Email: Lilicheng0510@163.com