Parameters
|
PTN 970
|
PTN 970C
|
PTN 980
|
PTN 990E
|
Switching Capacity
|
190 Gbit/s
|
190 Gbit/s
|
800 Gbit/s
|
1 Tbit/s
|
Number of Slots
|
8 slots: 2 for main control boards, 6 for service boards
|
8 slots: 2 for main control boards, 6 for service boards
|
10 slots: 2 for main control boards, 8 for service boards
|
16 slots: 2 for main control boards, 14 for service boards
|
Interface Capacity per Device
|
50 GE optical: 2
25 GE optical: 6 10 GE optical: 18 GE optical: 60 GE electrical: 48 FE optical: 60 FE electrical: 48 10M electrical: 48 STM-1 (VC4/VC12) optical: 24 E1: 192 |
50 GE optical: 2
25 GE optical: 6 10 GE optical: 18 GE optical: 60 GE electrical: 48 FE optical: 60 FE electrical: 48 10M electrical: 48 STM-1 (VC4/VC12) optical: 24 E1: 192 |
100 GE optical: 8
50 GE optical: 16 25 GE optical: 32 10 GE optical: 80 GE optical: 80 GE electrical: 32 FE optical: 80 FE electrical: 32 10M electrical: 32 STM-1 (VC4/VC12) optical: 16 E1: 128 |
100 GE optical: 10
50 GE optical: 20 25 GE optical: 40 10 GE optical: 100 GE optical: 140 GE electrical: 32 FE optical: 140 FE electrical: 32 STM-1 (VC4/VC12) optical: 16 E1: 128 |
Subrack Dimensions
(W x D x H) |
442 x 220 x 88.9 mm (2U)
|
442 x 220 x 88.9 mm (2U)
|
442 x 220 x 133.35 mm (3U)
|
442 x 220 x 222.25 mm (5U)
|
Weight (Empty Loaded)
|
4.2 kg
|
4.2 kg
|
5.7 kg
|
26.1kg
|
Working Voltage
|
–48V/–60V power supply: –40 V to –72 V
|
–48 V/–60 V power supply: –40 V to –73 V
|
–48V/–60V power supply: –40 V to –74 V
|
–48 V/–60 V power supply: –40 V to –75 V
|
Standard Power Consumption
|
247.56 W
|
247.56 W
|
432.5 W
|
480.24 W
|
Environment Requirements
|
Long-term working temperature: –20°C to 60°C
Storage temperature: –40°C to 70°C Long-term working relative humidity: 10% to 90% Long-term working altitude: ≤ 4000 m Storage altitude:< 5000 m |
Long-term working temperature: –20°C to +60°C
Storage temperature: –40°C to 70°C Long-term working relative humidity: 10% to 90% Long-term working altitude: ≤ 4000 m Storage altitude: < 5000 m |
Long-term working temperature: –20°C to 60°C
Storage temperature: –40°C to 70°C Long-term working relative humidity: 10% to 90% Storage relative humidity: 10% to 100% Long-term working altitude: ≤ 4000 m Storage altitude: < 5000 m |
Long-term working temperature: –5°C to 55°C
Storage temperature: –40°C to 70°C Long-term working relative humidity: 10% to 90% Storage relative humidity: 10% to 100% Long-term working altitude: ≤ 4000 m Storage altitude:< 5000 m |
Service Types
|
E-Line, E-LAN, CES
|
E-Line, E-LAN, CES
|
E-Line, E-LAN, CES
|
E-Line, E-LAN, CES
|
Service Protection
|
LMSP, LAG, MPLS Tunnel APS, PW APS, dual-homing protection, and ring network protection
|
LMSP, LAG, MPLS Tunnel APS, PW APS, dual-homing protection, and ring network protection
|
LMSP, LAG, MPLS Tunnel APS, PW APS, dual-homing protection, and ring network protection
|
LMSP, LAG, MPLS Tunnel APS, PW APS, dual-homing protection, and ring network protection
|
Email: Lilicheng0510@163.com