The S9303E chassis is 4 U high (1 U = 44.45 mm). When the chassis has no cable management frame installed, the dimensions (H x W x D) are 175 mm x 442 mm x 517.4 mm. When the chassis has cable management frames installed, the dimensions (H x W x D) are 175 mm x 442 mm x 585 mm.
System specifications of the S9300E
Item
|
Description
|
LPU slots
|
3
|
MCU slots
|
2
|
Fan slots
|
1
|
Power slots
|
2
|
Maximum port density
|
V200R001C00: 144xFE, 144xGE, 120x10GE
|
V200R002C00 and V200R003C00: 144xFE, 144xGE, 120x10GE, 6x40GE
|
|
V200R005C00, V200R006C00 and V200R007C00: 144xFE, 144xGE, 144x10GE, 6x40GE
|
|
V200R008C00 to V200R009C00: 144xFE, 144xGE, 144x10GE, 6x40GE, 6x100GE
|
|
V200R010C00 to V200R013C00: 144xFE, 144xGE, 144x10GE, 24x40GE, 12x100GE
|
|
Installation
|
In an N66E or N68E cabinet
|
CSS
|
Not supported
|
Maximum power consumption (fully configured)
|
1185 W
|
NOTE:
|
|
The heat dissipation value of a chassis equals the current power consumption of the chassis.
|
|
Power specifications
|
DC input voltage
|
Rated voltage: -48 V DC/-60 V DC
|
|
Maximum voltage range: -38.4 V DC to -72 V DC
|
|
AC input voltage
|
|
Rated voltage: 110 V AC/220 V AC, 50/60 Hz
|
|
Maximum voltage range: 90 V AC to 290 V AC; 47 Hz to 63 Hz (The output power reduces to half of the maximum output when the input
voltage is in the range of 90 V AC to 175 V AC.) |
|
HVDC input voltage (3000 W AC)
|
|
Rated voltage: 240 V DC
|
|
Maximum voltage range: 190 V DC to 290 V DC
|
|
HVDC input voltage (3000 W HVDC)
|
|
Rated voltage: 240 V DC/ 380 V DC
|
|
Maximum voltage range: 190 V DC to 400 V DC
|
|
Dimensions (H x W x D, without rack-mounting brackets)
|
With cable management frames (4 U high): 175 mm x 442 mm x 585 mm (6.9 in. x 17.4 in. x 23.0 in.)
|
Without cable management frames (4 U high): 175 mm x 442 mm x 517.4 mm (6.9 in. x 17.4 in. x 20.37 in.)
|
|
Weight (empty/fully configured)
|
11 kg/32.6 kg (24.3 lb/71.9 lb)
|
Reliability and availability
|
Mean time between failures (MTBF): 33.8 years
|
Mean time to repair (MTTR): 2 hours
|
|
Availability: 0.9999964
|
|
NOTE:
|
|
The preceding values are calculated based on the typical configuration of the product. The actual values will vary depending on
the modules installed on the product. |
|
Environment specifications
|
Operating temperature and altitude:
|
-60 m to +1800 m (-197 ft. to 5906 ft.): 0°C to 45°C (32°F to 113°F)
|
|
1800 m to 4000 m (5906 ft. to 13123 ft.): Operating temperature decreases by 1°C (1.8°F) every time the altitude increases 220 m
(722 ft.). |
|
4000 m (13123 ft.): 0°C to 35°C (32°F to 95°F)
|
|
Relative humidity: 5% RH to 95% RH (noncondensing)
|
|
Storage temperature: -40°C to +70°C (-40°F to +158°F)
|
|
Storage altitude: < 5000 m (16404 ft.)
|
|
Noise at normal temperature (acoustic power)
|
≤ 72 dB(A)
|
Certification
|
EMC certification
|
Safety certification
|
|
Manufacturing certification
|
|
Part number
|
2113477
|
1.Table And Wide Supply Chain System
We have established a perfect supply chain system to provide a wide range of products with reliable quality and reasonable price.
2.Competitive Price
We ensure the most competitive price.Warm reminders here, telecommunications equipment configuration is quite different, the price show
3.Safe And Easy Payment Solutions
We support a variety of payment methods, such as T/T, credit card, et
4.Strong Pre-Sales And After-Sales Services
To provide customers with professional pre- sales service, as well as after-sales technical Services
5.More Than 20 Years Industry Experience
We have been engaged in this industry more than 20 years, we have rich industry experience.
6.Fast Delivery And Shipping
Fast, professional and reliable delivery.
Q: How about your main products?
A:Our product lines include Switches.Routers,OLTs,SDHs. Network Modules, Interface Cards, Security Firewalls, Wireless AP etc.
Email: Lilicheng0510@163.com