Мы предоставляем клиентам различные коммуникационные продукты по разумным ценам и высококачественным продуктам и услугам
Description | Part Number | Modèle | First Supported Version | Remarks |
---|---|---|---|---|
NE40E-X3A Integrated DC Chassis Components, Including Dual DC Power | 02350FMK | CR5B0BKP0373 | V800R007C00 | - |
Item | Specification |
---|---|
Cabinet installation standards | Can be installed in a standard 19" 800 mm-deep cabinet. A 2.2 m-high N68E cabinet is used by default. |
Dimensions without packaging (H x W x D) [mm(in.)] | 264 mm x 442 mm x 710 mm (10.39 in. x 17.40 in. x 27.95 in.) (Chassis main body) 264 mm x 442 mm x 758 mm (10.39 in. x 17.40 in. x 29.84 in.) (Dimensions of the chassis body together with cable trays and front and back attachments) |
Chassis height [U] | 6 U |
Weight without packaging (base configuration) [kg(lb)] | 34.4 kg (75.85 lb) |
Weight without packaging (full configuration) [kg(lb)] | 72.1 kg (158.98 lb) |
Typical power consumption [W] | 1120 W (fully configured with LPUF-200s) |
Typical heat dissipation [BTU/hour] | 3633.8 BTU/hour (fully configured with LPUF-200s) |
MTBF [year] | 22.85 year |
MTTR [hour] | 0.5 hour |
Availability | 0.999997502 |
Power supply mode | DC built-in |
Maximum number of power chassis inputs | (1 channel/PEM)*2 PEM=2 channels |
Rated input voltage [V] | –48 V/ –60 V |
Input voltage range [V] | –40 V to –72 V |
Maximum input current [A] | 63 A/single-module |
Maximum input cable diameter [mm²] | 35 mm² |
Front-end circuit breaker/fuse [A] | 63 A |
Noise at normal temperature (acoustic power) [dB(A)] | NEBS-compliance (< 78 dBA @ 27°C (80.6°F)) |
Number of slots | 5 |
Number of service board slots | 3 |
Switching capacity | 2.76 tbps |
Redundant MPUs | 1:1 |
Redundant power supply | 1+1 |
Redundant fans | Support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) |
Long-term operating temperature [°C(°F)] | 0°C to 45°C (32°F to 113°F) |
Short-term operating temperature [°C(°F)] | -5°C to 55°C (23°F to 131°F) |
Restriction on the operating temperature variation rate [°C(°F)] | <000000>le; 30°C/hour (86°F/hour) |
Storage temperature [°C(°F)] | -40°C to 70°C (-40°F to 158°F) |
Long-term operating relative humidity [RH] | 5% RH to 85% RH, non-condensing |
Short-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | <000000>le; 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].) |
Storage altitude [m(ft.)] | Less than 5000 m (16404 ft.) |
Q: How about your main products?
Электронная почта:
Lilicheng0510@163.com