Item
|
CloudEngine S16700-4
|
CloudEngine S16700-8
|
|
mounting ears and cable management frames
|
ears and cable management frames
|
Chassis height [U]
|
9.8 U
|
15.8 U
|
Weight without packaging [kg(lb)]
|
94.1 kg (AC input)
|
129.8 kg (AC input)
|
98.1 kg (DC input)
|
135.8 kg (DC input)
|
|
Weight without packaging (full configuration) [kg(lb)]
|
162 kg (AC input)
|
253.1 kg (AC input)
|
163.6 kg (DC input)
|
255.1 kg (DC input)
|
|
Switching capacity
|
28.8 Tbit/s
|
57.6 Tbit/s
|
Packet forwarding rate
|
17760Mpps
|
35520Mpps
|
MPU slot
|
2
|
2
|
LPU slot
|
4
|
8
|
SFU slot
|
6 (can be expanded to 9 in the future)
|
6 (can be expanded to 9 in the future)
|
Fan module
|
3
|
3
|
System Power Supplies
|
6, dual inputs supported
|
10, dual inputs supported
|
Redundant power supply
|
⚫ Dual-input power supply system: N+1 backup is recommended.
|
⚫ Dual-input power supply system: N+1 backup is recommended.
|
⚫ Single-input power supply system: N+1 backup
|
⚫ Single-input power supply system: N+1 backup
|
|
Dual-input power supply is recommended to ensure reliability.
|
Dual-input power supply is recommended to ensure reliability.
|
|
Redundant fans
|
Fan modules work in hot standby mode. At the normal temperature range, the system can operate properly for a short time after a
single fan module fails. You are advised to replace the faulty fan module immediately. |
Fan modules work in hot standby mode. At the normal temperature range, the system can operate properly for a short time after a
single fan module fails. You are advised to replace the faulty fan module immediately. |
Rated input voltage
|
⚫ AC input: 220 V; 50 Hz/60 Hz
|
⚫ AC input: 220 V; 50 Hz/60 Hz
|
⚫ High-voltage DC (HVDC) input: 240 V/380 V
|
⚫ HVDC input: 240 V/380 V
|
|
⚫ DC input: –48 V/–60 V
|
⚫ DC input: –48 V/–60 V
|
|
Input voltage range
|
⚫ AC: 176 V to 290 V, 45 Hz to 65 Hz
|
⚫ AC: 176 V to 290 V, 45 Hz to 65 Hz
|
⚫ HVDC: 188 V to 288 V/260 V to 400 V
|
⚫ HVDC: 188 V to 288 V/260 V to 400 V
|
|
⚫ DC input: –40 V to –72 V
|
⚫ DC input: –40 V to –72 V
|
|
Maximum power consumption
|
4664 W
|
8260W
|
Maximum power output capability (including the system power output and PoE power output) [W]
|
AC input:
|
AC input:
|
⚫ 5+1 backup: 3000 W x 5 = 15000 W
|
⚫ 9+1 backup: 3000 W x 9 = 27000 W
|
|
⚫ 6+0 backup: 3000 W x 6 = 18000 W
|
⚫ 10+0 backup: 3000 W x 10 = 30000 W
|
|
DC input:
|
DC input:
|
|
⚫ 5+1 backup: 2200 W x 5 = 11000 W
|
⚫ 9+1 backup: 2200 W x 9 = 19800 W
|
|
⚫ 6+0 backup: 2200 W x 6 = 13200 W
|
⚫ 10+0 backup: 2200 W x 10 = 22000 W
|
|
Long-term operating temperature [°C(°F)]
|
0°C to 40°C (32°F to 140°F)
|
0°C to 40°C (32°F to 140°F)
|
Storage temperature [°C(°F)]
|
–40°C to +70°C (–40°F to +158°F)
|
–40°C to +70°C (–40°F to +158°F)
|
Relative humidity
|
5% RH to 85% RH (non-condensing)
|
5% RH to 85% RH (non-condensing)
|
Heat dissipation mode
|
Drawing air for heat dissipation
|
Drawing air for heat dissipation
|
Airflow direction
|
Front-to-rear airflow
|
Front-to-rear airflow
|
1.Table And Wide Supply Chain System
We have established a perfect supply chain system to provide a wide range of products with reliable quality and reasonable price.
2.Competitive Price
We ensure the most competitive price.Warm reminders here, telecommunications equipment configuration is quite different, the price show
3.Safe And Easy Payment Solutions
We support a variety of payment methods, such as T/T, credit card, et
4.Strong Pre-Sales And After-Sales Services
To provide customers with professional pre- sales service, as well as after-sales technical Services
5.More Than 20 Years Industry Experience
We have been engaged in this industry more than 20 years, we have rich industry experience.
6.Fast Delivery And Shipping
Fast, professional and reliable delivery.
Q: How about your main products?
A:Our product lines include Switches.Routers,OLTs,SDHs. Network Modules, Interface Cards, Security Firewalls, Wireless AP etc.
Email: Lilicheng0510@163.com