Part Number
|
98010744
|
Model
|
S1720-28GWR-4P-E
|
Description
|
S1720-28GWR-4P Bundle(24 Ethernet 10/100/1000 ports,4 Gig SFP,with license,AC 110/220V)
|
Wide [mm]
|
442.0 mm
|
||
Depth [mm]
|
224.8 mm
|
||
Height [mm]
|
43.6 mm
|
||
Chassis height [U]
|
1
|
||
Weight with packaging [kg(lb)]
|
3.9
|
||
Typical power consumption [W]
|
16.1
|
||
Maximum power consumption [W]
|
20.2
|
||
Typical heat dissipation [BTU/hour]
|
54.93
|
||
Maximum heat dissipation [BTU/hour]
|
68.92
|
||
Heat dissipation mode
|
Natural heat dissipation without fans
|
||
Power supply mode
|
AC built-in
|
||
Rated input voltage [V]
|
100 V AC to 240 V AC, 50/60 Hz
|
||
Input voltage range [V]
|
90 V AC to 264 V AC, 47 Hz to 63 Hz
|
||
Maximum input current [A]
|
0.8 A
|
||
Number of card slots
|
0
|
||
Number of power slots
|
0
|
||
Memory
|
512 MB
|
||
Flash memory
|
512 MB in total. To view the available flash memory size, run the display version command.
|
||
Redundant power supply
|
Not supported
|
||
Types of fans
|
None
|
||
Noise at normal temperature (acoustic pressure) [dB(A)]
|
Noise-free (no fans)
|
||
Noise at normal temperature (acoustic power) [dB(A)]
|
Noise-free (no fans)
|
||
Airflow direction
|
-
|
||
Long-term operating temperature [°C(°F)]
|
0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
|
||
Short-term operating temperature [°C(°F)]
|
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5906 ft.)
|
||
Storage temperature [°C(°F)]
|
-40°C to +70°C (-40°F to +158°F)
|
||
Restriction on the operating temperature variation rate
|
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). The operating temperature of the switch is 0°C to 40°C (32°F to 104°F) when it uses GE SFP optical modules with 40 km transmission distance. The equipment can operate beyond the normal operating temperature range for a short-term period, but the following conditions must be met: - The equipment operates at a temperature of over 45°C (113°F) consecutively for at most 96 hours in one year. - The equipment operates at a temperature of over 45°C (113°F) for a total of no more than 360 hours in one year. - The equipment operates at a temperature of over 45°C (113°F) for no more in 15 times in one year. The equipment may be damaged or experience unexpected exceptions if any of the preceding limits is exceeded. The equipment cannot start when the temperature is lower than 0°C (32°F). The maximum distance of optical modules used in these conditions cannot exceed 10 km.
|
||
Long-term operating relative humidity [RH]
|
5% to 95%, noncondensing
|
||
Long-term operating altitude [m(ft.)]
|
0-5000 m (0-16404 ft.)
|
||
Storage altitude [m(ft.)]
|
0-5000 m (0-16404 ft.)
|
||
MTBF [year]
|
45
|
||
MTTR [hour]
|
2
|
||
Availability
|
>0.99999
|
||
1000M electrical interface
|
24
|
||
1000M optical interface
|
4
|
||
USB
|
Not supported
|
||
Console port
|
Not supported
|
||
Eth Management port
|
Not supported
|
||
Service port surge protection
|
Common mode: ±7 kV
|
||
Power supply surge protection
|
±6 kV in differential mode, ±6 kV in common mode
|
||
RPS input
|
Not supported
|
||
PoE
|
Not supported
|