Installation Type
|
Rack,Work bench
|
||
Cabinet installation standard
|
Cabinet with a depth of 600 mm or above
|
||
Chassis height [U]
|
1
|
||
Weight without packaging [kg(lb)]
|
5.8 (12.79)
|
||
Weight with packaging [kg(lb)]
|
8.75 (19.29)
|
||
Maximum power consumption [W]
|
40
|
||
Maximum heat dissipation [BTU/hour]
|
136.8
|
||
Heat dissipation mode
|
The fan module locates at the air exhaust of the system.
|
||
Power supply mode
|
AC built-in
|
||
Rated input voltage [V]
|
100 V to 240 V, 50 Hz/60 Hz
|
||
Input voltage range [V]
|
90 V to 290 V, 47 Hz to 63 Hz
|
||
CPU
|
1 CPU, 4 cores/CPU, up to 1.4 GHz
|
||
Memory
|
DDR4 4 GB
|
||
NOR Flash
|
32 MB
|
||
Note: The NOR flash memory size of devices delivered later is 64 MB. You can run the display version command to check the NOR
flash memory size. |
|||
NAND Flash
|
2 GB
|
||
Hard disk
|
Optional. M.2 SSD (64GB/240GB), hot-swappable.
|
||
Redundant power supply
|
Two power modules are supported for 1+1 power redundancy.
|
||
Number of power modules
|
1
|
||
Number of fan modules
|
1
|
||
Types of fans
|
Pluggable
|
||
Airflow direction
|
Air inlet from front and air outlet from rear
|
||
Long-term operating temperature [°C(°F)]
|
0°C to 45°C
|
||
Storage temperature [°C(°F)]
|
-40°C to 70°C
|
||
Long-term operating relative humidity [RH]
|
5% RH to 95% RH, non-condensing
|
||
Storage relative humidity [RH]
|
5% RH to 95% RH, non-condensing
|
||
Long-term operating altitude [m(ft.)]
|
0 m to 5000 m
|
||
Storage altitude [m(ft.)]
|
0 m to 5000 m
|
||
MTBF [year]
|
68.98
|
||
MTTR [hour]
|
2
|
||
Console port
|
RJ45
|
||
Eth Management port
|
RJ45
|
||
Maximum number of 10GE ports
|
2
|
||
Maximum number of GE ports
|
8
|