1. Product series ID |
2. Indicator and button area |
3. HDD/SSD slot |
4. Fixed interface area |
5. Protective ground terminal |
|
6. MAC label |
7. SN label |
8. Fan module |
9. Power module |
- |
Component functions
|
Name |
Description |
|---|---|
|
Product series ID |
Indicates the product series of the device. For details about the product model, see the nameplate in the lower part of the device. |
|
Indicator and button area |
Provides multiple indicators to display the running status of the device in real time and provides the RSTand OFL buttons for emergency maintenance. |
|
HDD/SSD slot |
Houses hard disks for storing log and report data. |
|
Fixed interface area |
Provides service ports, USB ports, console ports, and out-of-band management ports for device configuration and maintenance. |
|
Protective ground terminal |
Connects the M4 OT terminal of a PGND cable to the cabinet or the ground bar in the equipment room. |
|
MAC label |
Uniquely identifies the MAC address of the device, which is required during network forwarding configuration. |
|
SN label |
Uniquely identifies the device, which needs to be provided for the local technical support personnel to apply for a license. |
|
Fan module |
Dissipates heat for the device and is swappable. The fan module can be removed for no more than 1 minute. |
|
Power module |
Provides power input and distribution for the device. Two power modules are included in the standard configuration to provide 1+1 power redundancy. When one power module is running properly, the other one is hot swappable. |
| lot Type | Slot ID | Slot Direction | Remarks |
|---|---|---|---|
| Hard disk (HDD/SSD) slot | - | Horizontal | 2.5-inch SATA hard disk (240 GB/960 GB/1000 GB) |
| Fan module slot | 1-4 | Horizontal | At the normal temperature range, the system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
| Power module (PWR) slot | 1-2 | Horizontal | PMs are plug-and-play. |
| Item | Specification |
|---|---|
| Installation Type | Rack |
| Cabinet installation standard |
|
| Dimensions without packaging (H x W x D) [mm(in.)] |
|
| Dimensions with packaging (H x W x D) [mm(in.)] | 260 mm x 590 mm x 790 mm |
| Chassis height [U] | 1 U |
| Weight with packaging [kg(lb)] | 15.48 kg (34.13 lb) |
| Weight without packaging [kg(lb)] | 10.26 kg (22.62 lb) |
| CPU |
|
| Memory |
|
| Storage | 32GB |
| NOR Flash | 64 MB/CPU, 128 MB in total |
| Hard disk |
|
| Console port | RJ45 |
| Eth Management port | RJ45 |
| Maximum power consumption [W] |
|
| Maximum heat dissipation [BTU/hour] |
|
| MTBF [years] | 42.63 years |
| MTTR [hours] | 2 hours |
| Power supply mode |
|
| Number of power modules | 2 |
| Rated input voltage [V] |
|
| Input voltage range [V] |
|
| Maximum input current [A] |
|
| Maximum output power [W] |
|
| Types of fans | Pluggable |
| Number of fan modules | 4 |
| Heat dissipation mode | Absorbing cold air into the device |
| Airflow direction |
|
| Maximum number of 100GE ports | 2 |
| Maximum number of 40GE ports | 4 |
| Maximum number of 25GE ports | 8 |
| Maximum number of 10GE ports | 28 |
| Maximum number of GE ports | 12 |
| Redundant power supply | 1+1 |
| Redundant fans | 3+1 |
| Noise at normal temperature (acoustic power) [db(A)] | ≤ 72 dB(A) |
| Long-term operating temperature [°C(°F)] |
|
| Storage temperature [°C(°F)] | -40°C to 70°C |
| Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
| Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
| Long-term operating altitude [m(ft.)] |
|
| Storage altitude [m(ft.)] |
|
Why Choose Us