Other part numbers
|
02356BCE(CE9865-4C Mainframe (With 4 Subcard Slots, Without Fan and Power Modules)) 02356BCJ(CE9865-4C mainframe (4*subcard slots,
4*AC power modules, 4*fan modules, 4*32 Port 100GE QSFP28 Interface card,port-side intake)) 02356HYJ(CE9865-4C mainframe (4*subcard slots, 4*AC power modules, 4*fan modules, 4*8 Port 400GE QSFP-DD Interface card,port-side intake)) |
Installation Type
|
Cabinet installation
|
Profondità [mm]
|
mm765
|
Altezza telaio [U]
|
4 |
Largo [mm]
|
mm442
|
Altezza [mm]
|
mm175
|
Peso con imballaggio [kg(lb)]
|
53.7 kg (118.39 lb) (excluding fan modules, power modules, and cards)
|
Peso senza imballaggio [kg(lb)]
|
28.7 kg (63.27 lb) (excluding fan modules, power modules, and cards)
|
Consumo energetico massimo [W]
|
Configured with four CE98-D32CQ-F cards: 1854 W (100% traffic load, 128-port 100G-SR4 optical modules, normal temperature, fully
configured with AC power modules) Configured with four CE98-D8DQ-F cards: 1457 W (100% traffic load, 32-port 400G-SR8 optical modules, normal temperature, fully configured with AC power modules) Configured with four CE98-D32CQ-F cards: 2597 W (100% traffic load, 128-port 100G-LR4 optical modules, high temperature, fully configured with AC power modules) Configured with four CE98-D8DQ-F cards: 1831 W (100% traffic load, 32-port 400G-FR4 optical modules, high temperature, fully configured with AC power modules) |
Consumo energetico tipico [W]
|
Configured with four CE98-D32CQ-F cards: 1465 W (100% traffic load, 64-port 100G-SR4 optical modules, normal temperature, fully
configured with AC power modules) Configured with four CE98-D8DQ-F cards: 1140 W (100% traffic load, 16-port 400G-SR8 optical modules, normal temperature, fully configured with AC power modules) |
Static power consumption [W]
|
Configured with four CE98-D32CQ-F cards: 1083 W Configured with four CE98-D8DQ-F cards: 847 W
|
Modalità di dissipazione del calore
|
Air cooling
|
Dissipazione massima del calore [BTU/ora]
|
Configured with four CE98-D32CQ-F cards: 6326 BTU/hour (100% traffic load, 128-port 100G-SR4 optical modules, normal temperature,
fully configured with AC power modules) Configured with four CE98-D8DQ-F cards: 4971 BTU/hour (100% traffic load, 32-port 400G-SR8 optical modules, normal temperature, fully configured with AC power modules) Configured with four CE98-D32CQ-F cards: 8861 BTU/hour (100% traffic load, 128-port 100G-LR4 optical modules, high temperature, fully configured with AC power modules) Configured with four CE98-D8DQ-F cards: 6248 BTU/hour (100% traffic load, 32-port 400G-FR4 optical modules, high temperature, fully configured with AC power modules) |
Dissipazione del calore tipica [BTU/ora]
|
Configured with four CE98-D32CQ-F cards: 4999 BTU/hour (100% traffic load, 64-port 100G-SR4 optical modules, normal temperature,
fully configured with AC power modules) Configured with four CE98-D8DQ-F cards: 3890 BTU/hour (100% traffic load, 16-port 400G-SR8 optical modules, normal temperature, fully configured with AC power modules) |
Static heat dissipation [BTU/hour]
|
Configured with four CE98-D32CQ-F cards: 3695 BTU/hour Configured with four CE98-D8DQ-F cards: 2890 BTU/hour
|
Modalità di alimentazione
|
AC pluggable,DC pluggable,HVDC pluggable
|
Tensione di ingresso nominale [V]
|
- 2000 W AC&240 V DC power module: AC: 100 V AC to 240 V AC, 50/60 Hz; DC: 240 V DC - 2200 W DC power module: –48 V DC to –60 V
DC; +48 V DC - 2000 W high-voltage DC power module: 336 V DC |
Intervallo di tensione di ingresso [V]
|
- 2000 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz; DC: 190 V DC to 290 V DC - 2200 W DC power module:
–38.4 V DC to –72 V DC; +38.4 V DC to +57 V DC - 2000 W high-voltage DC power module: 260 V DC to 400 V DC |
Corrente massima di ingresso [A]
|
- 2000 W AC&240 V DC power module: 10 A (100 V AC to 240 V AC); 10 A (240 V DC) - 2200 W DC power module: 63 A (–48 V DC to –60 V
DC); 63 A (+48 V DC) - 2000 W high-voltage DC power module: 10 A (336 V DC) |
Potenza nominale in uscita [W]
|
- 2000 W AC&240 V DC power module: 2000 W (220 V AC to 240 V AC&240 V DC), 1800 W (200 V AC to 220 V AC), 900 W (100 V AC to 130 V
AC) - 2200 W DC power module: 2200 W - 2000 W high-voltage DC power module: 2000 W |
Memoria
|
DRAM: 16 GB
|
NOR Flash
|
64 MB x 2
|
SSD Flash
|
8GB
|
USB
|
Supportato
|
Porta della console
|
RJ45
|
Downlink Service interface
|
The device does not have fixed ports and provides four card slots. Currently, the device supports the following cards:
CE98-D32CQ-F: 32 x 100GE QSFP28 1. Each 100GE QSFP28 port can be configured to work at 40 Gbit/s. 2. Only the top-row ports can be split. Every four ports form a group. When a 40GE/100GE port is split into 4 x 10GE or 4 x 25GE ports, the other top-row port is also split, and the bottom-row ports in the same group become unavailable. For example, ports 1, 2, 3, and 4 form a group. Quando port 1 is split, port 3 is also split, and ports 2 and 4 are unavailable. Only ports with optical modules can be split, and ports with copper cables cannot be split. 3. Support for optical modules: 40GE-SR4/LR4/eSR4/ER4/BIDI/eSDLC/SDLC/LX4/eSR4 and AOC, as well as 100G-SR4/PSM4/CWDM4/LR4/SWDM4/4WDM/BIDI/LX4/DR1/FR1/LR1/ER4 optical modules are supported. When the ambient temperature ranges from 0°Da C a 35°C (32°Da F a 95°F), 100G-ZR4 is supported, but the device noise will exceed the threshold. 4. Support for copper cables: 40GE/100GE 1/3/5 m passive copper cables are supported. Copper cable auto-negotiation and splitting are not supported. Copper cables can only be used on M-LAG peer-link ports. CE98-D8DQ-F: 8 x 400GE QSFP-DD 1. 400GE ports cannot be configured as 200GE, 100GE, or 40GE ports. 2. A 400GE port can be split into 4 x 100GE or 2 x 200GE ports. Only ports with optical modules can be split, and ports with copper cables cannot be split. 3. Support for optical modules: (1) 400GE ports support optical modules such as 400GE-SR8/eSR8/LR8/DR4/FR4/ER8/ZR and AOC. (2) 400G-ZR+ optical module: When the ambient temperature ranges from 0°Da C a 35°C (32°Da F a 95°F), only ports 1, 3, 5, and 7 in slots 3 and 4 support 400G-ZR+ optical modules. Each card supports four 400G-ZR+ optical modules, and a total of eight 400G-ZR+ optical modules are supported. In the ambient temperature, the device noise increases to 83 dBA. Ports 1 and 2, 3 and 4, 5 and 6, and 7 and 8 form different groups. In each group, only the port with a smaller port number supports 400G-ZR+. For example, if a 400G-ZR+ optical module is inserted into port 1, port 2 becomes unavailable and no optical module can be inserted. 4. Support for copper cables: 400GE 1 m/2.5 m copper cables are supported. (For 400GE 1 m copper cables, only QSFP-DD-400G-CU1M is supported, and QSFP-DD-400G-CU1M-S is not supported.) Copper cable auto-negotiation and splitting are not supported. Copper cables can only be used on M-LAG peer-link ports. |
Service port supporting the stack function
|
Non supportato
|
RTC
|
Supportato
|
Switching capacity [bps,bit/s]
|
To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel.
|
Ventilatori ridondanti
|
The device supports 3+1 backup of fan modules that work in hot standby mode. The system can operate properly for a short period of
time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Alimentazione ridondante
|
2+2 backup
|
Number of power modules
|
4 |
Protezione contro le sovratensioni dell&39;alimentazione
|
AC: 6 kV in common mode and 6 kV in differential mode DC: 4 kV in common mode and 2 kV in differential mode HVDC: 4 kV in common
mode and 2 kV in differential mode |
Tipi di ventilatori
|
Pluggable
|
Number of fans
|
4 |
Direzione del flusso d&39;aria
|
Back-to-front airflow: Air flows into the chassis from the port side and flows out from the power supply side.
|
Temperatura di conservazione [°C(°F)]
|
-40ºDa C a +70ºC (-40°Da F a +158°F)
|
Temperatura di esercizio a lungo termine [°C(°F)]
|
0°Da C a 40°C (32°Da F a 104°F) at an altitude of 0–1800 m (0–5906 ft.) Note: When the altitude is 1800–5000 metri (5096–16404 ft.), the
highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Umidità relativa di stoccaggio [RH]
|
5% to 95% RH, non-condensing
|
Umidità relativa di funzionamento a lungo termine [RH]
|
5% RH al 95% RH, senza condensa
|
Altitudine di stoccaggio [m(ft.)]
|
<000000>le; 5000 m (16404 ft.)
|
Altitudine operativa a lungo termine [m(ft.)]
|
<000000>le; 5000 m (16404 ft.)
|
MTBF [anno]
|
anni25.50
|
MTTR [ora]
|
ore1.5
|
Noise at high temperature (40°C, sound pressure)
|
Back-to-front airflow: 78.2 dB(A) on average (maximum: 88 dB(A))
|
Noise at normal temperature (27°C, sound pressure)
|
Back-to-front airflow: 60.6 dB(A) on average (maximum: 69 dB(A))
|
Disponibilità
|
0.9999932861
|
Certificazione
|
Complies with safety standards.
|
Complies with EMC standards.
| |
Complies with environmental protection standards.
| |
Power supply surge protection [kV]
|
AC: 6 kV in common mode and 6 kV in differential mode
|
DC: 4 kV in common mode and 2 kV in differential mode
| |
HVDC: 4 kV in common mode and 2 kV in differential mode
| |
Tipi di ventilatori
|
Pluggable
|
Number of fans
|
4 |
Ventilatori ridondanti
|
Supports 3+1 backup. Fan modules work in hot backup mode. If a fan module fails, the system can still work properly for a short
period of time. However, you are advised to replace the faulty fan module immediately. |
Modalità di dissipazione del calore
|
Air cooling
|
Direzione del flusso d&39;aria
|
Back-to-front airflow: Air flows into the chassis from the port side and flows out from the power supply side.
|
Disponibilità
|
0.999997861
|
MTBF [anno]
|
anno42.79
|
MTTR [ora]
|
ora1.73
|
Noise at normal temperature (27°C, sound pressure) [dB(A)]
|
Back-to-front airflow: < 66 dB(A)
|
Noise at high temperature (40°C, sound pressure) [dB(A)]
|
Back-to-front airflow: < 81 dB(A)
|
Long-term operating altitude [m (ft.)]
|
<000000>le; 5000 m (16404 ft.)
|
Umidità relativa di funzionamento a lungo termine [RH]
|
5% RH al 95% RH, senza condensa
|
Temperatura di esercizio a lungo termine [°C (°F)]
|
0°Da C a 40°C (32°Da F a 104°F) at an altitude of 0–1800 m (0–5906 ft.)
|
NOTE:
| |
When the altitude is 1800–5000 metri (5096–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) ogni volta che il
l&39;altitudine aumenta di 220 m (722 piedi). | |
Storage altitude [m (ft.)]
|
<000000>le; 5000 m (16404 ft.)
|
Umidità relativa di stoccaggio [RH]
|
5% to 95% RH, non-condensing
|
Temperatura di conservazione [°C (°F)]
|
-40ºDa C a +70ºC (-40°Da F a +158°F)
|
1.Tabella e sistema di catena di fornitura ampia
Abbiamo creato un sistema di filiera perfetto per offrire un&39;ampia gamma di prodotti di qualità affidabile e a prezzi ragionevoli.
2. Prezzo competitivo
Garantiamo il prezzo più competitivo. Promemoria caldi qui, la configurazione delle apparecchiature di telecomunicazione è piuttosto diversa, il prezzo mostra
3.Soluzioni di pagamento sicure e facili
Supportiamo una varietà di metodi di pagamento, come T/T, carta di credito, ecc.
4.Forti servizi pre-vendita e post-vendita
Per fornire ai clienti un servizio pre-vendita professionale, nonché servizi tecnici post-vendita
5. Oltre 20 anni di esperienza nel settore
Siamo impegnati in questo settore da più di 20 anni e vantiamo una vasta esperienza nel settore.
6. Consegna e spedizione veloci
Consegna veloce, professionale e affidabile.
D: E i vostri prodotti principali?
A: Le nostre linee di prodotti includono switch, router, OLT e SDH. Moduli di rete, schede di interfaccia, firewall di sicurezza, punti di accesso wireless ecc.
البريد الإلكتروني:
Lilicheng0510@163.com