Мы предоставляем клиентам различные коммуникационные продукты по разумным ценам и высококачественным продуктам и услугам
Other part numbers
|
02356BCE(CE9865-4C Mainframe (With 4 Subcard Slots, Without Fan and Power Modules)) 02356BCJ(CE9865-4C mainframe (4*subcard slots,
4*AC power modules, 4*fan modules, 4*32 Port 100GE QSFP28 Interface card,port-side intake)) 02356HYJ(CE9865-4C mainframe (4*subcard slots, 4*AC power modules, 4*fan modules, 4*8 Port 400GE QSFP-DD Interface card,port-side intake)) |
Installation Type
|
Cabinet installation
|
Profondeur [mm]
|
765 mm
|
Hauteur du châssis [U]
|
4 |
Largeur [mm]
|
442 mm
|
Hauteur [mm]
|
175 mm
|
Poids avec emballage [kg(lb)]
|
53.7 kg (118.39 lb) (excluding fan modules, power modules, and cards)
|
Poids sans emballage [kg(lb)]
|
28.7 kg (63.27 lb) (excluding fan modules, power modules, and cards)
|
Consommation électrique maximale [W]
|
Configured with four CE98-D32CQ-F cards: 1854 W (100% traffic load, 128-port 100G-SR4 optical modules, normal temperature, fully
configured with AC power modules) Configured with four CE98-D8DQ-F cards: 1457 W (100% traffic load, 32-port 400G-SR8 optical modules, normal temperature, fully configured with AC power modules) Configured with four CE98-D32CQ-F cards: 2597 W (100% traffic load, 128-port 100G-LR4 optical modules, high temperature, fully configured with AC power modules) Configured with four CE98-D8DQ-F cards: 1831 W (100% traffic load, 32-port 400G-FR4 optical modules, high temperature, fully configured with AC power modules) |
Consommation électrique typique [W]
|
Configured with four CE98-D32CQ-F cards: 1465 W (100% traffic load, 64-port 100G-SR4 optical modules, normal temperature, fully
configured with AC power modules) Configured with four CE98-D8DQ-F cards: 1140 W (100% traffic load, 16-port 400G-SR8 optical modules, normal temperature, fully configured with AC power modules) |
Static power consumption [W]
|
Configured with four CE98-D32CQ-F cards: 1083 W Configured with four CE98-D8DQ-F cards: 847 W
|
Mode de dissipation thermique
|
Air cooling
|
Dissipation thermique maximale [BTU/heure]
|
Configured with four CE98-D32CQ-F cards: 6326 BTU/hour (100% traffic load, 128-port 100G-SR4 optical modules, normal temperature,
fully configured with AC power modules) Configured with four CE98-D8DQ-F cards: 4971 BTU/hour (100% traffic load, 32-port 400G-SR8 optical modules, normal temperature, fully configured with AC power modules) Configured with four CE98-D32CQ-F cards: 8861 BTU/hour (100% traffic load, 128-port 100G-LR4 optical modules, high temperature, fully configured with AC power modules) Configured with four CE98-D8DQ-F cards: 6248 BTU/hour (100% traffic load, 32-port 400G-FR4 optical modules, high temperature, fully configured with AC power modules) |
Dissipation thermique typique [BTU/heure]
|
Configured with four CE98-D32CQ-F cards: 4999 BTU/hour (100% traffic load, 64-port 100G-SR4 optical modules, normal temperature,
fully configured with AC power modules) Configured with four CE98-D8DQ-F cards: 3890 BTU/hour (100% traffic load, 16-port 400G-SR8 optical modules, normal temperature, fully configured with AC power modules) |
Static heat dissipation [BTU/hour]
|
Configured with four CE98-D32CQ-F cards: 3695 BTU/hour Configured with four CE98-D8DQ-F cards: 2890 BTU/hour
|
Mode d&39;alimentation
|
AC pluggable,DC pluggable,HVDC pluggable
|
Tension d&39;entrée nominale [V]
|
- 2000 W AC&240 V DC power module: AC: 100 V AC to 240 V AC, 50/60 Hz; DC: 240 V DC - 2200 W DC power module: –48 V CC à –60 V
DC; +48 V DC - 2000 W high-voltage DC power module: 336 V DC |
Plage de tension d&39;entrée [V]
|
- 2000 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz; DC: 190 V DC to 290 V DC - 2200 W DC power module:
–38,4 V CC à –72 V DC; +38.4 V DC to +57 V DC - 2000 W high-voltage DC power module: 260 V DC to 400 V DC |
Courant d&39;entrée maximal [A]
|
- 2000 W AC&240 V DC power module: 10 A (100 V AC to 240 V AC); 10 A (240 V DC) - 2200 W DC power module: 63 A (–48 V CC à –60 V
DC); 63 A (+48 V DC) - 2000 W high-voltage DC power module: 10 A (336 V DC) |
Puissance de sortie nominale [W]
|
- 2000 W AC&240 V DC power module: 2000 W (220 V AC to 240 V AC&240 V DC), 1800 W (200 V AC to 220 V AC), 900 W (100 V AC to 130 V
AC) - 2200 W DC power module: 2200 W - 2000 W high-voltage DC power module: 2000 W |
Mémoire
|
DRAM: 16 GB
|
NOR Flash
|
64 MB x 2
|
SSD Flash
|
8GB
|
USB
|
Soutenu
|
Port de console
|
RJ45
|
Downlink Service interface
|
The device does not have fixed ports and provides four card slots. Currently, the device supports the following cards:
CE98-D32CQ-F: 32 x 100GE QSFP28 1. Each 100GE QSFP28 port can be configured to work at 40 Gbit/s. 2. Only the top-row ports can be split. Every four ports form a group. When a 40GE/100GE port is split into 4 x 10GE or 4 x 25GE ports, the other top-row port is also split, and the bottom-row ports in the same group become unavailable. For example, ports 1, 2, 3, and 4 form a group. When port 1 is split, port 3 is also split, and ports 2 and 4 are unavailable. Only ports with optical modules can be split, and ports with copper cables cannot be split. 3. Support for optical modules: 40GE-SR4/LR4/eSR4/ER4/BIDI/eSDLC/SDLC/LX4/eSR4 and AOC, as well as 100G-SR4/PSM4/CWDM4/LR4/SWDM4/4WDM/BIDI/LX4/DR1/FR1/LR1/ER4 optical modules are supported. When the ambient temperature ranges from 0°C à 35°C (32°F à 95°F), 100G-ZR4 is supported, but the device noise will exceed the threshold. 4. Support for copper cables: 40GE/100GE 1/3/5 m passive copper cables are supported. Copper cable auto-negotiation and splitting are not supported. Copper cables can only be used on M-LAG peer-link ports. CE98-D8DQ-F: 8 x 400GE QSFP-DD 1. 400GE ports cannot be configured as 200GE, 100GE, or 40GE ports. 2. A 400GE port can be split into 4 x 100GE or 2 x 200GE ports. Only ports with optical modules can be split, and ports with copper cables cannot be split. 3. Support for optical modules: (1) 400GE ports support optical modules such as 400GE-SR8/eSR8/LR8/DR4/FR4/ER8/ZR and AOC. (2) 400G-ZR+ optical module: When the ambient temperature ranges from 0°C à 35°C (32°F à 95°F), only ports 1, 3, 5, and 7 in slots 3 and 4 support 400G-ZR+ optical modules. Each card supports four 400G-ZR+ optical modules, and a total of eight 400G-ZR+ optical modules are supported. In the ambient temperature, the device noise increases to 83 dBA. Ports 1 and 2, 3 and 4, 5 and 6, and 7 and 8 form different groups. In each group, only the port with a smaller port number supports 400G-ZR+. For example, if a 400G-ZR+ optical module is inserted into port 1, port 2 becomes unavailable and no optical module can be inserted. 4. Support for copper cables: 400GE 1 m/2.5 m copper cables are supported. (For 400GE 1 m copper cables, only QSFP-DD-400G-CU1M is supported, and QSFP-DD-400G-CU1M-S is not supported.) Copper cable auto-negotiation and splitting are not supported. Copper cables can only be used on M-LAG peer-link ports. |
Service port supporting the stack function
|
Non pris en charge
|
RTC
|
Soutenu
|
Switching capacity [bps,bit/s]
|
To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel.
|
Ventilateurs redondants
|
The device supports 3+1 backup of fan modules that work in hot standby mode. The system can operate properly for a short period of
time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Alimentation électrique redondante
|
2+2 backup
|
Number of power modules
|
4 |
Protection contre les surtensions de l&39;alimentation électrique
|
AC: 6 kV in common mode and 6 kV in differential mode DC: 4 kV in common mode and 2 kV in differential mode HVDC: 4 kV in common
mode and 2 kV in differential mode |
Types de ventilateurs
|
Pluggable
|
Number of fans
|
4 |
Direction du flux d&39;air
|
Back-to-front airflow: Air flows into the chassis from the port side and flows out from the power supply side.
|
Température de stockage [°C(°F)]
|
-40ºC à +70ºC (-40°F à +158°F)
|
Température de fonctionnement à long terme [°C(°F)]
|
0°C à 40°C (32°F à 104°F) at an altitude of 0–1800 m (0–5906 ft.) Note: When the altitude is 1800–5000 m (5096–16404 ft.), the
highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Humidité relative de stockage [HR]
|
5% to 95% RH, non-condensing
|
Humidité relative de fonctionnement à long terme [HR]
|
5 % HR à 95 % HR, sans condensation
|
Altitude de stockage [m(ft.)]
|
<000000>le; 5000 m (16404 ft.)
|
Altitude de fonctionnement à long terme [m(ft.)]
|
<000000>le; 5000 m (16404 ft.)
|
MTBF [année]
|
25.50 années
|
MTTR [heure]
|
1.5 heures
|
Noise at high temperature (40°C, sound pressure)
|
Back-to-front airflow: 78.2 dB(A) on average (maximum: 88 dB(A))
|
Noise at normal temperature (27°C, sound pressure)
|
Back-to-front airflow: 60.6 dB(A) on average (maximum: 69 dB(A))
|
Disponibilité
|
0.9999932861
|
Certification
|
Complies with safety standards.
|
Complies with EMC standards.
| |
Complies with environmental protection standards.
| |
Power supply surge protection [kV]
|
AC: 6 kV in common mode and 6 kV in differential mode
|
DC: 4 kV in common mode and 2 kV in differential mode
| |
HVDC: 4 kV in common mode and 2 kV in differential mode
| |
Types de ventilateurs
|
Pluggable
|
Number of fans
|
4 |
Ventilateurs redondants
|
Supports 3+1 backup. Fan modules work in hot backup mode. If a fan module fails, the system can still work properly for a short
period of time. However, you are advised to replace the faulty fan module immediately. |
Mode de dissipation thermique
|
Air cooling
|
Direction du flux d&39;air
|
Back-to-front airflow: Air flows into the chassis from the port side and flows out from the power supply side.
|
Disponibilité
|
0.999997861
|
MTBF [année]
|
42.79 année
|
MTTR [heure]
|
1.73 heure
|
Noise at normal temperature (27°C, sound pressure) [dB(A)]
|
Back-to-front airflow: < 66 dB(A)
|
Noise at high temperature (40°C, sound pressure) [dB(A)]
|
Back-to-front airflow: < 81 dB(A)
|
Long-term operating altitude [m (ft.)]
|
<000000>le; 5000 m (16404 ft.)
|
Humidité relative de fonctionnement à long terme [HR]
|
5 % HR à 95 % HR, sans condensation
|
Température de fonctionnement à long terme [°C (°F)]
|
0°C à 40°C (32°F à 104°F) at an altitude of 0–1800 m (0–5906 ft.)
|
NOTE:
| |
When the altitude is 1800–5000 m (5096–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) chaque fois que le
l&39;altitude augmente de 220 m (722 pi). | |
Storage altitude [m (ft.)]
|
<000000>le; 5000 m (16404 ft.)
|
Humidité relative de stockage [HR]
|
5% to 95% RH, non-condensing
|
Température de stockage [°C (°F)]
|
-40ºC à +70ºC (-40°F à +158°F)
|
1. Système de chaîne d&39;approvisionnement à grande échelle
Nous avons mis en place un système de chaîne d&39;approvisionnement parfait pour fournir une large gamme de produits avec une qualité fiable et un prix raisonnable.
2. Prix compétitif
Nous garantissons le prix le plus compétitif. Rappels chaleureux ici, la configuration des équipements de télécommunications est assez différente, le prix montre
3. Solutions de paiement sûres et faciles
Nous prenons en charge une variété de méthodes de paiement, telles que T/T, carte de crédit, etc.
4.Services avant-vente et après-vente performants
Fournir aux clients un service avant-vente professionnel, ainsi que des services techniques après-vente
5. Plus de 20 ans d&39;expérience dans l&39;industrie
Nous sommes engagés dans cette industrie depuis plus de 20 ans, nous avons une riche expérience de l&39;industrie.
6. Livraison et expédition rapides
Livraison rapide, professionnelle et fiable.
Q : Qu&39;en est-il de vos principaux produits ?
R : Nos gammes de produits comprennent des commutateurs, des routeurs, des OLT et des SDH. Modules réseau, cartes d&39;interface, pare-feu de sécurité, points d&39;accès sans fil, etc.
Электронная почта:
Lilicheng0510@163.com
Flat/RM P, 4/F, Lladro Center, 72 Hoi Yuen Road, Квун Тонг, Гонконг, Китай