Other part numbers
|
02356BCE(CE9865-4C Mainframe (With 4 Subcard Slots, Without Fan and Power Modules)) 02356BCJ(CE9865-4C mainframe (4*subcard slots,
4*AC power modules, 4*fan modules, 4*32 Port 100GE QSFP28 Interface card,port-side intake)) 02356HYJ(CE9865-4C mainframe (4*subcard slots, 4*AC power modules, 4*fan modules, 4*8 Port 400GE QSFP-DD Interface card,port-side intake)) |
Installation Type
|
Cabinet installation
|
Depth [mm]
|
765 mm
|
Chassis height [U]
|
4
|
Wide [mm]
|
442 mm
|
Height [mm]
|
175 mm
|
Weight with packaging [kg(lb)]
|
53.7 kg (118.39 lb) (excluding fan modules, power modules, and cards)
|
Weight without packaging [kg(lb)]
|
28.7 kg (63.27 lb) (excluding fan modules, power modules, and cards)
|
Maximum power consumption [W]
|
Configured with four CE98-D32CQ-F cards: 1854 W (100% traffic load, 128-port 100G-SR4 optical modules, normal temperature, fully
configured with AC power modules) Configured with four CE98-D8DQ-F cards: 1457 W (100% traffic load, 32-port 400G-SR8 optical modules, normal temperature, fully configured with AC power modules) Configured with four CE98-D32CQ-F cards: 2597 W (100% traffic load, 128-port 100G-LR4 optical modules, high temperature, fully configured with AC power modules) Configured with four CE98-D8DQ-F cards: 1831 W (100% traffic load, 32-port 400G-FR4 optical modules, high temperature, fully configured with AC power modules) |
Typical power consumption [W]
|
Configured with four CE98-D32CQ-F cards: 1465 W (100% traffic load, 64-port 100G-SR4 optical modules, normal temperature, fully
configured with AC power modules) Configured with four CE98-D8DQ-F cards: 1140 W (100% traffic load, 16-port 400G-SR8 optical modules, normal temperature, fully configured with AC power modules) |
Static power consumption [W]
|
Configured with four CE98-D32CQ-F cards: 1083 W Configured with four CE98-D8DQ-F cards: 847 W
|
Heat dissipation mode
|
Air cooling
|
Maximum heat dissipation [BTU/hour]
|
Configured with four CE98-D32CQ-F cards: 6326 BTU/hour (100% traffic load, 128-port 100G-SR4 optical modules, normal temperature,
fully configured with AC power modules) Configured with four CE98-D8DQ-F cards: 4971 BTU/hour (100% traffic load, 32-port 400G-SR8 optical modules, normal temperature, fully configured with AC power modules) Configured with four CE98-D32CQ-F cards: 8861 BTU/hour (100% traffic load, 128-port 100G-LR4 optical modules, high temperature, fully configured with AC power modules) Configured with four CE98-D8DQ-F cards: 6248 BTU/hour (100% traffic load, 32-port 400G-FR4 optical modules, high temperature, fully configured with AC power modules) |
Typical heat dissipation [BTU/hour]
|
Configured with four CE98-D32CQ-F cards: 4999 BTU/hour (100% traffic load, 64-port 100G-SR4 optical modules, normal temperature,
fully configured with AC power modules) Configured with four CE98-D8DQ-F cards: 3890 BTU/hour (100% traffic load, 16-port 400G-SR8 optical modules, normal temperature, fully configured with AC power modules) |
Static heat dissipation [BTU/hour]
|
Configured with four CE98-D32CQ-F cards: 3695 BTU/hour Configured with four CE98-D8DQ-F cards: 2890 BTU/hour
|
Power supply mode
|
AC pluggable,DC pluggable,HVDC pluggable
|
Rated input voltage [V]
|
- 2000 W AC&240 V DC power module: AC: 100 V AC to 240 V AC, 50/60 Hz; DC: 240 V DC - 2200 W DC power module: –48 V DC to –60 V
DC; +48 V DC - 2000 W high-voltage DC power module: 336 V DC |
Input voltage range [V]
|
- 2000 W AC&240 V DC power module: AC: 90 V AC to 290 V AC, 45 Hz to 65 Hz; DC: 190 V DC to 290 V DC - 2200 W DC power module:
–38.4 V DC to –72 V DC; +38.4 V DC to +57 V DC - 2000 W high-voltage DC power module: 260 V DC to 400 V DC |
Maximum input current [A]
|
- 2000 W AC&240 V DC power module: 10 A (100 V AC to 240 V AC); 10 A (240 V DC) - 2200 W DC power module: 63 A (–48 V DC to –60 V
DC); 63 A (+48 V DC) - 2000 W high-voltage DC power module: 10 A (336 V DC) |
Rated output power [W]
|
- 2000 W AC&240 V DC power module: 2000 W (220 V AC to 240 V AC&240 V DC), 1800 W (200 V AC to 220 V AC), 900 W (100 V AC to 130 V
AC) - 2200 W DC power module: 2200 W - 2000 W high-voltage DC power module: 2000 W |
Memory
|
DRAM: 16 GB
|
NOR Flash
|
64 MB x 2
|
SSD Flash
|
8GB
|
USB
|
Supported
|
Console port
|
RJ45
|
Downlink Service interface
|
The device does not have fixed ports and provides four card slots. Currently, the device supports the following cards:
CE98-D32CQ-F: 32 x 100GE QSFP28 1. Each 100GE QSFP28 port can be configured to work at 40 Gbit/s. 2. Only the top-row ports can be split. Every four ports form a group. When a 40GE/100GE port is split into 4 x 10GE or 4 x 25GE ports, the other top-row port is also split, and the bottom-row ports in the same group become unavailable. For example, ports 1, 2, 3, and 4 form a group. When port 1 is split, port 3 is also split, and ports 2 and 4 are unavailable. Only ports with optical modules can be split, and ports with copper cables cannot be split. 3. Support for optical modules: 40GE-SR4/LR4/eSR4/ER4/BIDI/eSDLC/SDLC/LX4/eSR4 and AOC, as well as 100G-SR4/PSM4/CWDM4/LR4/SWDM4/4WDM/BIDI/LX4/DR1/FR1/LR1/ER4 optical modules are supported. When the ambient temperature ranges from 0°C to 35°C (32°F to 95°F), 100G-ZR4 is supported, but the device noise will exceed the threshold. 4. Support for copper cables: 40GE/100GE 1/3/5 m passive copper cables are supported. Copper cable auto-negotiation and splitting are not supported. Copper cables can only be used on M-LAG peer-link ports. CE98-D8DQ-F: 8 x 400GE QSFP-DD 1. 400GE ports cannot be configured as 200GE, 100GE, or 40GE ports. 2. A 400GE port can be split into 4 x 100GE or 2 x 200GE ports. Only ports with optical modules can be split, and ports with copper cables cannot be split. 3. Support for optical modules: (1) 400GE ports support optical modules such as 400GE-SR8/eSR8/LR8/DR4/FR4/ER8/ZR and AOC. (2) 400G-ZR+ optical module: When the ambient temperature ranges from 0°C to 35°C (32°F to 95°F), only ports 1, 3, 5, and 7 in slots 3 and 4 support 400G-ZR+ optical modules. Each card supports four 400G-ZR+ optical modules, and a total of eight 400G-ZR+ optical modules are supported. In the ambient temperature, the device noise increases to 83 dBA. Ports 1 and 2, 3 and 4, 5 and 6, and 7 and 8 form different groups. In each group, only the port with a smaller port number supports 400G-ZR+. For example, if a 400G-ZR+ optical module is inserted into port 1, port 2 becomes unavailable and no optical module can be inserted. 4. Support for copper cables: 400GE 1 m/2.5 m copper cables are supported. (For 400GE 1 m copper cables, only QSFP-DD-400G-CU1M is supported, and QSFP-DD-400G-CU1M-S is not supported.) Copper cable auto-negotiation and splitting are not supported. Copper cables can only be used on M-LAG peer-link ports. |
Service port supporting the stack function
|
Not supported
|
RTC
|
Supported
|
Switching capacity [bps,bit/s]
|
To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel.
|
Redundant fans
|
The device supports 3+1 backup of fan modules that work in hot standby mode. The system can operate properly for a short period of
time after a single fan module fails. You are advised to replace the faulty fan module immediately. |
Redundant power supply
|
2+2 backup
|
Number of power modules
|
4
|
Power supply surge protection
|
AC: 6 kV in common mode and 6 kV in differential mode DC: 4 kV in common mode and 2 kV in differential mode HVDC: 4 kV in common
mode and 2 kV in differential mode |
Types of fans
|
Pluggable
|
Number of fans
|
4
|
Airflow direction
|
Back-to-front airflow: Air flows into the chassis from the port side and flows out from the power supply side.
|
Storage temperature [°C(°F)]
|
-40ºC to +70ºC (-40°F to +158°F)
|
Long-term operating temperature [°C(°F)]
|
0°C to 40°C (32°F to 104°F) at an altitude of 0–1800 m (0–5906 ft.) Note: When the altitude is 1800–5000 m (5096–16404 ft.), the
highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage relative humidity [RH]
|
5% to 95% RH, non-condensing
|
Long-term operating relative humidity [RH]
|
5% RH to 95% RH, non-condensing
|
Storage altitude [m(ft.)]
|
≤ 5000 m (16404 ft.)
|
Long-term operating altitude [m(ft.)]
|
≤ 5000 m (16404 ft.)
|
MTBF [year]
|
25.50 years
|
MTTR [hour]
|
1.5 hours
|
Noise at high temperature (40°C, sound pressure)
|
Back-to-front airflow: 78.2 dB(A) on average (maximum: 88 dB(A))
|
Noise at normal temperature (27°C, sound pressure)
|
Back-to-front airflow: 60.6 dB(A) on average (maximum: 69 dB(A))
|
Availability
|
0.9999932861
|
Certification
|
Complies with safety standards.
|
Complies with EMC standards.
|
|
Complies with environmental protection standards.
|
|
Power supply surge protection [kV]
|
AC: 6 kV in common mode and 6 kV in differential mode
|
DC: 4 kV in common mode and 2 kV in differential mode
|
|
HVDC: 4 kV in common mode and 2 kV in differential mode
|
|
Types of fans
|
Pluggable
|
Number of fans
|
4
|
Redundant fans
|
Supports 3+1 backup. Fan modules work in hot backup mode. If a fan module fails, the system can still work properly for a short
period of time. However, you are advised to replace the faulty fan module immediately. |
Heat dissipation mode
|
Air cooling
|
Airflow direction
|
Back-to-front airflow: Air flows into the chassis from the port side and flows out from the power supply side.
|
Availability
|
0.999997861
|
MTBF [year]
|
42.79 year
|
MTTR [hour]
|
1.73 hour
|
Noise at normal temperature (27°C, sound pressure) [dB(A)]
|
Back-to-front airflow: < 66 dB(A)
|
Noise at high temperature (40°C, sound pressure) [dB(A)]
|
Back-to-front airflow: < 81 dB(A)
|
Long-term operating altitude [m (ft.)]
|
≤ 5000 m (16404 ft.)
|
Long-term operating relative humidity [RH]
|
5% RH to 95% RH, non-condensing
|
Long-term operating temperature [°C (°F)]
|
0°C to 40°C (32°F to 104°F) at an altitude of 0–1800 m (0–5906 ft.)
|
|
|
NOTE:
|
|
When the altitude is 1800–5000 m (5096–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the
altitude increases by 220 m (722 ft.). |
|
|
|
Storage altitude [m (ft.)]
|
≤ 5000 m (16404 ft.)
|
Storage relative humidity [RH]
|
5% to 95% RH, non-condensing
|
Storage temperature [°C (°F)]
|
-40ºC to +70ºC (-40°F to +158°F)
|
1.Table And Wide Supply Chain System
We have established a perfect supply chain system to provide a wide range of products with reliable quality and reasonable price.
2.Competitive Price
We ensure the most competitive price.Warm reminders here, telecommunications equipment configuration is quite different, the price show
3.Safe And Easy Payment Solutions
We support a variety of payment methods, such as T/T, credit card, et
4.Strong Pre-Sales And After-Sales Services
To provide customers with professional pre- sales service, as well as after-sales technical Services
5.More Than 20 Years Industry Experience
We have been engaged in this industry more than 20 years, we have rich industry experience.
6.Fast Delivery And Shipping
Fast, professional and reliable delivery.
Q: How about your main products?
A:Our product lines include Switches.Routers,OLTs,SDHs. Network Modules, Interface Cards, Security Firewalls, Wireless AP etc.
Email: Lilicheng0510@163.com