Description | Part Number | Model | First Supported Version | Remarks |
---|---|---|---|---|
NE40E-X8A Integrated Chassis HVDC Components(2T, Including 3 Fan Tray) | 02351TWY | CR5B0BKP0875 | V800R010C10 | - |
Item | Specification |
---|---|
Cabinet installation standards | Can be installed in a standard 19" 1000 mm-deep cabinet, part number is 02115109(CR5B0N610E60) |
Dimensions without packaging (H x W x D) [mm(in.)] | 930 mm x 442 mm x 941 mm (36.61 in. x 17.40 in. x 37.05 in.) (Dimensions of the chassis body together with cable trays and front and back attachments and noise reduction module) |
Chassis height [U] | 21 U |
Weight without packaging (base configuration) [kg(lb)] | 79.9 kg (176.15 lb) |
Weight without packaging (full configuration) [kg(lb)] |
[400G bundle] 184.3 kg (406.31 lb) [1T bundle] 206.5 kg (455.25 lb) [2T bundle] 234.4 kg (516.76 lb) |
Typical power consumption [W] |
4110 W (fully configured with LPUF-240s) 4770 W (fully configured with LPUF-480s) 6520 W (fully configured with LPUI-1Ts) 11100 W (fully configured with LPUI-2Ts) |
Typical heat dissipation [BTU/hour] |
13334.6 BTU/hour (fully configured with LPUF-240s) 15475.9 BTU/hour (fully configured with LPUF-480s) 21153.6 BTU/hour (fully configured with LPUI-1Ts) 36013.1 BTU/hour (fully configured with LPUI-2Ts) |
MTBF [year] | 22.32 year |
MTTR [hour] | 0.5 hour |
Availability | 0.999997443 |
Power supply mode | HVDC built-in |
Maximum number of power chassis inputs | (4 channels/PEM)*2 PEMs = (1 channel/PM)*4 PMs*2 PEMs = 8 channels |
Rated input voltage [V] | 240V/380V |
Input voltage range [V] | 192 to 288V,264 to 400V |
Maximum input current [A] | 14 A/single-module |
Maximum input cable diameter [mm²] | 2.5 mm² |
Front-end circuit breaker/fuse [A] |
14 A/single-module [400G bundle] HVDC device: 6 PMs, with a total of 6 channels of 14 A [1T bundle] HVDC device: 8 PMs, with a total of 8 channels of 14 A [2T bundle] HVDC device: 8 PMs, with a total of 8 channels of 14 A |
Noise at normal temperature (acoustic power) [dB(A)] | NEBS-compliance (< 78 dBA @ 27°C (80.6°F)) |
Number of slots | 12 |
Number of service board slots | 8 |
Switching capacity | 51.2 Tbps (LPUI-2T) |
Redundant MPUs | 1:1 |
Redundant Switch fabrics | 3+1 |
Redundant power supply |
[400G bundle] 3+3 [1T bundle] 4+1 [2T bundle] 5+1 |
Redundant fans |
[400G bundle] 2 assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) [1T bundle] 3 assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) [2T bundle] 3 assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) |
Long-term operating temperature [°C(°F)] | 0°C to 45°C (32°F to 113°F) |
Short-term operating temperature [°C(°F)] | -5°C to 55°C (23°F to 131°F) |
Restriction on the operating temperature variation rate [°C(°F)] | ≤ 30°C/hour (86°F/hour) |
Storage temperature [°C(°F)] | -40°C to 70°C (-40°F to 158°F) |
Long-term operating relative humidity [RH] | 5% RH to 85% RH, non-condensing |
Short-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | ≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].) |
Storage altitude [m(ft.)] | Less than 5000 m (16404 ft.) |
Q: How about your main products?
Email: Lilicheng0510@163.com