Brindamos a los clientes varios productos de comunicación a precios razonables y productos y servicios de alta calidad.
| 描述 | 零件編號 | 模型 | First Supported Version | 評論 |
|---|---|---|---|---|
| NE40E-X8A Integrated Chassis DC Components(Including 2 Fan Tray) | 02350AFW | CR5B0BKP0871 | V800R006C20 | - |
數位 1 Appearance of the NE40E-X8A
| 物品 | 規格 |
|---|---|
| Cabinet installation standards | Can be installed in a standard 19" 800 mm-deep cabinet. A 2.2 m-high N68E cabinet is used by default. |
| 不含包裝的尺寸(高 x 寬 x 深)[毫米(英吋)] | 930 mm x 442 mm x 650 mm (36.61 in. x 17.40 英寸 x 25.59 in.) (Chassis main body) 930 mm x 442 mm x 750 mm (36.61 in. x 17.40 英寸 x 29.53 in.) (Dimensions of the chassis body together with cable trays and front and back attachments) |
| 底盤高度 [U] | 21 U |
| Weight without packaging (base configuration) [kg(lb)] | 78.9 kg (173.94 lb) |
| Weight without packaging (full configuration) [kg(lb)] | [400G bundle] 186.1 kg (410.28 lb) [1T bundle] 209 kg (460.77 lb) |
| 典型功耗 [W] | 4110 W (fully configured with LPUF-240s) 4770 W (fully configured with LPUF-480s) 6520 W (fully configured with LPUI-1Ts) |
| 典型散熱量 [BTU/小時] | 13334.6 BTU/hour (fully configured with LPUF-240s) 15475.9 BTU/hour (fully configured with LPUF-480s) 21153.6 BTU/hour (fully configured with LPUI-1Ts) |
| MTBF [year] | 22.32 年 |
| MTTR [hour] | 0.5 hour |
| 可用性 | 0.999997443 |
| 供電方式 | DC built-in |
| Maximum number of power chassis inputs | (8 channels/PEM)*2 PEM=(2 channels/PM)*4 PM*2 PEM=16 channels |
| 額定輸入電壓[V] | –48 V/ –60 V |
| 輸入電壓範圍[V] | –40 V to –72 V |
| 最大輸入電流 [A] | 63 A/single-module |
| Maximum input cable diameter [mm²] | 35 毫米²/channel |
| Front-end circuit breaker/fuse [A] | 2 channels of 63 A/single-module [400G bundle] DC device: 4 PMs, with a total of 8 channels of 63 A [1T bundle] DC device: 6 PMs, with a total of 12 channels of 63 A |
| 常溫噪音(聲功率)[dB(A)] | NEBS-compliance (< 78 dBA @ 27°C (80.6°F)) |
| Number of slots | 12 |
| Number of service board slots | 8 |
| Switching capacity | 25.16 Tbps (LPUI-1T) |
| Redundant MPUs | 1:1 |
| Redundant Switch fabrics | 3+1 |
| 冗餘電源 | [400G bundle] :3+1 [1T bundle] 5+1 |
| Redundant fans | [400G bundle] 2 assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) [1T bundle] 3 assemblies in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) |
| 長期工作溫度[°C(°F)] | 0°C 至 45°C (32°F 至 113°F) |
| 短期工作溫度[°C(°F)] | -5°C 至 55°C (23°F 至 131°F) |
| 工作溫度變化率的限制[°C(°F)] | <000000>le; 30°C/hour (86°F/hour) |
| 儲存溫度[°C(°F)] | -40°C 至 70°C (-40°F 至 158°F) |
| 長期工作相對濕度[RH] | 5% to 85% RH, non-condensing |
| Short-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
| Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
| 長期工作高度 [m(ft.)] | <000000>le; 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].) |
| 儲存高度 [米(英尺)] | Less than 5000 m (16404 ft.) |
Q:你們的主要產品怎麼樣?
Correo electrónico:
Lilicheng0510@163.com
Flat/Rm P, 4/F, Lladro Center, 72 Hoi Yuen Road, Kwun Tong, Hong Kong, China