FusionPod 700 Cabinet Dimensions (H x W x D)
• Full liquid cooling (including front door and RDHx): without casters: 2200 mm x 600 mm x 1400 mm (86.61 in. x 23.62 in. x 55.11 in.), with casters: 2250 mm × 600 mm × 1400 mm (88.58 in. x 23.62 in. x 55.11 in.) • Board-level liquid cooling (including front door and normal back door): without casters: 2200 mm x 600 mm x 1200 mm (86.61 in. x 23.62 in. x 47.24 in.), with casters: 2250 mm × 600 mm × 1200 mm (88.58 in. x 23.62 in. x 47.24 in.) Technical Specifications • Available space: 47 U • Server node: 36 x 1 U server nodes • Switching node: 4 service switching nodes, 1 out-of-band management switching node, and 1+1 redundancy of service switching nodes • Cabinet management node: 1 cabinet management module Power Supply • Power supply requirement: AC: 4 PSU modules in 2+2 redundancy mode, 380 V/32 A • PSU module: 11+1 PSU, 3 kW Cabinet Power and Heat Dissipation • System maximum power consumption: 33 KW (backup) and 36 kW (no backup) • Heat dissipation methods: liquid cooling + air cooling Environmental Specifications • Operating temperature: 5°C to 45°C (41°F to 113°F) (ASHRAE Classes A1 to A3 compliant) • Storage temperature (within three months): -30°C to +60°C (-22°F to +140°F) • Storage temperature (within six months): -15°C to +45°C (5°F to 113°) • Storage temperature (within one year): -10°C to +35°C (14°F to 95°F) • Maximum temperature change rate: 20°C (36°F) per hour, 5°C (9°F) per 15 minutes Humidity (RH and No Condensing) • Operating humidity: 8% to 90% • Storage humidity (within three months): 8% to 85% • Storage humidity (within six months): 8% to 80% • Storage humidity (within one year): 20% to 75% • Maximum change rate: 20%/h Altitude • Operating altitude: no more than 3050 m (10,006.56 ft) - When the server configuration complies with ASHRAE Class A2 standards and the altitude is above 900 m (2,952.76 ft.), the operating temperature decreases by 1°C (1.8°F) for every increase of 300 m (984.24 ft.) - When the server configuration complies with ASHRAE Class A3 standards and the altitude is above 900 m (2,952.76 ft.), the operating temperature decreases by 1°C (1.8°F) for every increase of 175 m (574.15 ft) - When the configuration complies with ASHRAE Class A4 standards and the altitude is above 900 m (2,952.76 ft.), the operating temperature decreases by 1°C (1.8°F) for every increase of 125 m (410.10 ft) Installation • Installation dimensions: cabinet projection area: 600 mm x 1350 mm (23.62 in. x 53.15 in.); reserve at least 1.2 m (3.94 ft) space for maintenance in front of and behind the cabinet • Package size (W x H x D): 980 mm x 2405 mm x 1310 mm (except the front door and the back door) • Fully loaded weight: 1200 Kg • Cabinet package weight: 34.8 kg • Equipment room: no less than 1000 kg/m² • Equipment room floor height: no less than 600 mm • Manifold pipe installation port: 1-inch flange quick port • RDHx pipe installation port: 1-inch flange quick port Cooling • Manifold water supply requirement: pH value: ≥ 6.5; glycol-concentration: 25% ± 5% (volume concentration); total microorganism count: < 105 CFU/mL Turbidity: no visible impurities in the filter net • Manifold water supply temperature: 5ºC to 45ºC (41°F to 113°F) • Manifold recommended water supply temperature: 30ºC (86°F) • Manifold water supply flow: 32 LPM • Manifold water supply maximum pressure: 350 KPa • Manifold supply and return water pressure difference: 35 KPa at 25% glycol solution |
Email: Lilicheng0510@163.com