Installation type
|
Rack
|
Height [mm]
|
44.4 mm
|
Depth [mm]
|
420.0 mm
|
Wide [mm]
|
442.0 mm
|
Chassis height [U]
|
1
|
Weight with packaging [kg]
|
9 (19.84)
|
Weight without packaging [kg]
|
5.8 (12.79)
|
CPU
|
2.0 GHz, 16 cores
|
Memory
|
16 GB
|
NAND Flash
|
4 GB
|
Console port
|
RJ45
|
RTC
|
Supported
|
WAN ports
|
10 x 10GE (SFP+), 8 x GE combo, 4 x GE copper
|
Number of service board slots
|
4
|
MIC slots (default/maximum)
|
0/0
|
SIC slots (default/maximum)
|
4/4
|
WSIC slots (default/maximum)
|
0/2
|
XSIC slots (default/maximum)
|
0/1
|
Maximum number of FE ports
|
12
|
Maximum number of GE ports
|
12
|
Maximum number of 2.5GE ports
|
0
|
Maximum number of 5GE ports
|
0
|
Maximum number of 10GE ports
|
10
|
Maximum number of 25GE ports
|
0
|
Maximum number of 40GE ports
|
0
|
Redundant power supply
|
Dual power supplies in 1:1 backup mode
|
Redundant MPUs
|
Not supported
|
RPS input
|
Not supported
|
PoE
|
Not supported
|
IP rating
|
IP20
|
MTBF [year]
|
37.80
|
MTTR [h]
|
2
|
Availability
|
0.9999939599
|
Maximum power consumption [W]
|
191
|
Typical power consumption [W]
|
168
|
Power supply mode
|
AC/HVDC pluggable, DC pluggable
|
Number of power modules
|
2
|
Input voltage range [V]
|
AC: 90 V to 290 V, 45 Hz to 65 Hz HVDC: 190 V to 290 V DC: -38.4 V to -72 V / +38.4 V to +57 V
|
Rated input voltage [V]
|
Rated AC input voltage: 100 V to 240 V, 50 Hz or 60 Hz HVDC: 240 V Rated DC input voltage: -48 V DC to -60 V DC
|
Maximum input current [A]
|
350 W AC: 5.5 A 350 W HVDC: 2.5 A 240 W DC: 8 A
|
Maximum output power
|
350 W AC: 350 W 350 W HVDC: 350 W 240 W DC: 240 W
|
Types of fans
|
Built-in
|
Number of fan modules
|
5
|
Heat dissipation mode
|
Air cooling
|
Airflow
|
Left-to-right airflow
|
Noise at normal temperature (acoustic power)
|
57.6
|
Storage temperature [°C]
|
-40°C to +70°C (-40°F to +158°F)
|
Long-term operating temperature [°C]
|
0°C to 45°C (32°F to 113°F) Note: When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
|
Long-term operating relative humidity [RH]
|
5% RH to 95% RH, non-condensing
|
Long-term operating altitude [m]
|
< 5000 m (16404.2 ft.)
|
Overtemperature alarm
|
Supported
|
Environmental standards compliance
|
RoHS REACH WEEE
|
Safety regulation certification
|
IEC 60950-1 IEC 62368-1 EN 60950-1 UL 60950-1 CSA C22.2 No 60950-1 GB 4943.1
|
EMC certification
|
EN 55032 EN 55035 CISPR 32 CISPR 35 IEC/EN 61000-3-2 EN 61000-3-3 ETSI EN 300 386 ETSI EN 301 489-1 ETSI EN 301 489-3 ETSI EN 301 489-17 ETSI EN 301 489-52 FCC CFR Part 15, Subpart B ANSI C63.4 ICES-003 Issue 7 EN 50121-1 EN 50121-4 GB 9254
|
Email: Lilicheng0510@163.com