Efficient Processing for Diverse Data
Software algorithms are offloaded onto processors for hardware acceleration. In addition, OceanStor scale-out storage uses an intelligent and lossless network that delivers consistent latency of less than 1 ms1, quickly responding to critical workloads.
A single bucket houses up to 100 billion objects without compromising performance, eliminating the need to use multiple buckets for large applications.
Excellent input/output (I/O) throughput is provided for applications that involve a massive volume of small files. Fully symmetric distributed architecture enables massive and linear performance expansion.
Full-lifecycle storage system management predicts and handles resource usage and faults in advance, radically streamlining operations and maintenance (O&M).
Notes:1 Applicable to scale-out block storage.
The OceanStor scale-out storage series implements EC to deliver industry-leading disk space utilization of 91.6%. That's 2.75x the figure of a traditional three-copy mode, slashing the hardware needed and the physical space required, as well as bringing down energy consumption.
The series provides state-of-the-art data reduction solutions for life sciences and digital pathology, optimizing the use of storage space.
The series also scales out to 4,096 nodes, for flexible resource purchasing and deployment on demand.
It provides precision purchasing with a sales model of available capacity4, optimizing investments made.
Equipped with native Hadoop Distributed File System (HDFS) capabilities, the decoupled storage-compute big data solution is compatible with mainstream big data platforms and components, for diversified data analytics with 30% lower total cost of ownership (TCO).
|
Product Model
|
OceanStor Pacific 9540
|
|
|
System Architecture
|
Fully symmetric distributed architecture
|
|
|
Storage Access Protocol
|
NFS, SMB, POSIX, MPI-IO, HDFS, and S3
|
SCSI, iSCSI, and OpenStack Cinder
|
|
Raw Capacity per Chassis
|
216 TB to 576 TB
|
216 TB to 576 TB
|
|
Height per Chassis
|
4U
|
4U
|
|
Number of Nodes per Chassis
|
1
|
1
|
|
Max. Number of Primary Storage Disks per Node
|
36
|
36
|
|
Primary Storage Disk Type
|
3.5-inch HDD
|
3.5-inch HDD
|
|
Processors per Node
|
2 x Kunpeng 920 Processors or 2 x Intel® Xeon® Scalable Processors
|
2 x Kunpeng 920 Processors or 2 x Intel® Xeon® Scalable Processors
|
|
Max. Memory per Node
|
512 GB
|
512 GB, 768 GB, or 1 TB
|
|
Max. Cache per Node
|
4 x NVMe SSDs
|
4 x NVMe or SAS SSDs
|
|
Number of System Disks per Node
|
2 x 600 GB SAS HDDs
|
2 x 600 GB SAS HDDs
|
|
Front-End Service Network Type*
|
• 10 GE, 25 GE, or 100 GE TCP/IP
|
• 10 GE or 25 GE TCP/IP
|
|
• 25 GE or 100 GE RoCE
|
• 25 GE RoCE
|
|
|
• 100 Gbit/s EDR InfiniBand
|
||
|
Storage Network Type
|
• 10 GE, 25 GE or 100 GE TCP/IP
|
• 10 GE or 25 GE TCP/IP
|
|
• 10 GE, 25 GE or 100 GE RoCE
|
• 25 GE RoCE
|
|
|
• 100 Gb/s InfiniBand
|
||
|
Data Redundancy Protection Mechanism
|
EC: N + M (M is 2, 3, or 4)
|
EC: N + M (M is 2, 3, or 4)
|
|
Data Self-Healing
|
Automatic concurrent data reconstruction at 2 TB per hour
|
Automatic concurrent data reconstruction at 4 TB per hour
|
|
Key Features
|
• SmartQuota
|
• SmartThin
|
|
• SmartTier
|
• SmartDedupe & SmartCompression
|
|
|
• SmartQoS
|
• SmartQoS
|
|
|
• SmartEqualizer
|
• SmartAuditlog
|
|
|
• SmartMulti-Tenant
|
• SmartEncyption
|
|
|
• SmartEncryption
|
• HyperSnap
|
|
|
• SmartAuditlog
|
• HyperClone
|
|
|
• HyperLock(WORM)
|
• HyperMetro
|
|
|
• HyperSnap
|
• HyperReplication(S)
|
|
|
• HyperReplication(A)
|
• HyperReplication(A)
|
|
|
• SmartIndexing
|
• MultiPool
|
|
|
• Recycle Bin
|
• DIF
|
|
|
• SmartInterworking
|
||
|
• DIF
|
||
|
• Object Versioning*
|
||
|
• SmartTakeover*
|
||
|
• SmartCompression
|
||
|
• HyperGeoMetro*
|
||
|
• HyperGeoEC*
|
||
|
Storage Management Software
|
DeviceManager and eService
|
|
|
Chassis Dimensions (H x W x D)
|
• Kunpeng model: 175 x 447 x 790 mm
|
• Kunpeng model: 175 x 447 x 790 mm
|
|
• x86 model: 175 x 447 x 748 mm
|
• x86 model: 175 x 447 x 748 mm
|
|
|
Max. Weight per Chassis (with Disks)
|
≤ 65 kg
|
|
|
Operating Temperature
|
5°C to 35°C
|
|
|
Operating Humidity
|
8% RH to 90% RH (non-condensing)
|
|
Email: Lilicheng0510@163.com