Description | Part Number | Model | First Supported Version | Remarks |
---|---|---|---|---|
NE40E-X16 Integrated Chassis Components (Including 4*PFU and Eight DC Power) | 02351931 | CR5B0BKP1670 | V800R006C20 | - |
Item | Specification |
---|---|
Cabinet installation standards | Can be installed in a standard 19" 800 mm-deep cabinet. A H w 2.2 m-high N68E cabinet is used by default. |
Dimensions without packaging (H x W x D) [mm(in.)] |
1420 mm x 442 mm x 650 mm (55.91 in. x 17.40 in. x 25.59 in.) (Chassis main body) 1420 mm x 442 mm x 770 mm (55.91 in. x 17.40 in. x 30.31 in.) (Dimensions of the chassis body together with cable trays and front and back attachments) |
Chassis height [U] | 32 U |
Weight without packaging (base configuration) [kg(lb)] | 94.4 kg (208.15 lb) |
Weight without packaging (full configuration) [kg(lb)] | 279 kg (615.2 lb) |
Typical power consumption [W] | 6210 W (fully configured with LPUF-240s) |
Typical heat dissipation [BTU/hour] | 20147.9 BTU/hour (fully configured with LPUF-240s) |
MTBF [year] | 22.32 year |
MTTR [hour] | 0.5 hour |
Availability | 0.999997365 |
Power supply mode | DC built-in |
Maximum number of power chassis inputs | (1 channel/PEM)*8 PEM=8 channels |
Rated input voltage [V] | –48 V/ –60 V |
Input voltage range [V] | –38.4 V to –72 V |
Maximum input current [A] | 70 A/module (8 modules in total, 4+4 backup) |
Maximum input cable diameter [mm²] | 35 mm²/channel |
Front-end circuit breaker/fuse [A] | 70 A |
Noise at normal temperature (acoustic power) [dB(A)] | NEBS-compliance (< 78 dBA @ 27°C (80.6°F)) |
Number of slots | 22 |
Number of service board slots | 16 |
Switching capacity | 12.58 Tbps(LPUF-240/LPUI-240) |
Redundant MPUs | 1:1 |
Redundant Switch fabrics | 3+1 |
Redundant power supply | 4+4 |
Redundant fans |
2 partitions 2 assemblies/partition, each partition in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) |
Long-term operating temperature [°C(°F)] | 0°C to 45°C (32°F to 113°F) |
Short-term operating temperature [°C(°F)] | -5°C to 55°C (23°F to 131°F) |
Restriction on the operating temperature variation rate [°C(°F)] | ≤ 30°C/hour (86°F/hour) |
Storage temperature [°C(°F)] | -40°C to 70°C (-40°F to 158°F) |
Long-term operating relative humidity [RH] | 5% RH to 85% RH, non-condensing |
Short-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | ≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].) |
Storage altitude [m(ft.)] | Less than 5000 m (16404 ft.) |