Item
|
Details
|
Description
|
48 x 10M/100M/1000M Base-T ports , 4 x 10GE SFP+ ports +, 2 x 12GE stack ports
|
Part Number
|
98012030
|
Model
|
S5735-S24P4XE-V2
|
First supported version
|
V600R022C01
|
Item
|
Specification
|
Dimensions without packaging (H x W x D) [mm(in.)]
|
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.)
|
Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm
x 442.0 mm x 446.0 mm (1.72 in. x 17.40 in. x 17.56 in.) |
|
Dimensions with packaging (H x W x D) [mm(in.)]
|
185 mm x 650 mm x 550 mm (7.28 in. x 25.59 in. x 21.65 in.)
|
Chassis height [U]
|
1 U
|
Weight without packaging [kg(lb)]
|
4.80 kg (10.58 lb)
|
Weight with packaging [kg(lb)]
|
7.74 kg (17.06 lb)
|
Typical power consumption [W]
|
43.18 W
|
Typical heat dissipation [BTU/hour]
|
147.33 BTU/hour
|
Maximum power consumption [W]
|
Without PoE: 87.51 W
|
Full PoE load: 1023.22 W (PoE: 840 W)
|
|
Maximum heat dissipation [BTU/hour]
|
Without PoE: 298.59
|
Full PoE load: 3491.33
|
|
MTBF [year]
|
120.24 year
|
MTTR [hour]
|
2 hour
|
Availability
|
>0.99999
|
Noise at normal temperature (acoustic power) [dB(A)]
|
Three 600 W AC PoE power modules with 30% load: 49 dBA
|
Three 1000 W AC PoE power modules with 30% load: 48.5 dBA
|
|
Three 1000 W DC PoE power modules with 30% load: 47.3 dBA
|
|
Noise at normal temperature (acoustic pressure) [dB(A)]
|
Three 600 W AC PoE power modules with 30% load: 37 dBA
|
Three 1000 W AC PoE power modules with 30% load: 36.9 dBA
|
|
Three 1000 W DC PoE power modules with 30% load: 35.5 dBA
|
|
Number of card slots
|
0
|
Number of power slots
|
3
|
Number of fans modules
|
2
|
Redundant power supply
|
1+1+1
|
Pluggable AC and DC power modules can be used together on the same device.
|
|
Long-term operating temperature [°C(°F)]
|
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.)
|
Restriction on the operating temperature variation rate [°C(°F)]
|
When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the
altitude increases by 220 m (722 ft.). |
Devices cannot start when the temperature is lower than 0°C (32°F).
|
|
Storage temperature [°C(°F)]
|
–40°C to +70°C (–40°F to +158°F)
|
Long-term operating relative humidity [RH]
|
5% RH to 95% RH (non-condensing)
|
Long-term operating altitude [m(ft.)]
|
0–5000 m (0–16404 ft.)
|
Storage altitude [m(ft.)]
|
0-5000 m (0-16404 ft.)
|
Power supply mode
|
Pluggable power supply
|
Rated input voltage [V]
|
AC input: 100 V AC to 130 V AC, 200 V AC to 240 V AC; 50/60 Hz
|
High-voltage DC input: 240 V DC
|
|
DC input: –48 V DC to –60 V DC
|
|
Input voltage range [V]
|
AC input: 90 V AC to 290 V AC; 45–65 Hz
|
High-voltage DC input: 190 V DC to 290 V DC
|
|
DC input: -38.4 V DC to -72 V DC
|
|
Maximum input current [A]
|
The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules.
|
Memory
|
2 GB
|
Flash memory
|
1 GB in total. To view the available flash memory size, run the display version command.
|
Console port
|
RJ45
|
Eth Management port
|
Not supported
|
USB
|
Supported
|
RTC
|
Not supported
|
RPS input
|
Not supported
|
Service port surge protection [kV]
|
Common mode: ±7 kV
|
Power supply surge protection [kV]
|
Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode
|
Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode
|
|
Types of fans
|
Built-in
|
Heat dissipation mode
|
Air cooling for heat dissipation, intelligent fan speed adjustment
|
Airflow direction
|
Air intake from left, front, and right and air exhaust from rear
|
PoE
|
Supported
|
Certification
|
EMC certification
|
Safety certification
|
|
Manufacturing certification
|
Q: How about your main products?