Item
|
Specification
|
Dimensions without packaging (H x W x D) [mm(in.)]
|
Basic dimensions (excluding the parts protruding from the body): 150.0 mm x 120.0 mm x 133.0 mm (5.91 in. x 4.72 in. x 5.24 in.)
|
|
Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 162.0 mm
x 120.0 mm x 142.0 mm (6.38 in. x 4.72 in. x 5.59 in.) |
Dimensions with packaging (H x W x D) [mm(in.)]
|
175.0 mm x 280.0 mm x 230.0 mm (6.89 in. x 11.02 in. x 9.06 in.)
|
Weight without packaging [kg(lb)]
|
2.08 kg (4.59 lb)
|
Weight with packaging [kg(lb)]
|
2.54 kg (5.6 lb)
|
Typical power consumption [W]
|
25.3 W (12 V power supply, 25°C, no wind, 100% traffic)
|
|
27.9 W (48 V power supply, 25°C, no wind, 100% traffic)
|
Typical heat dissipation [BTU/hour]
|
86 (12 V power supply, 25°C, no wind, 100% traffic)
|
|
95 (48 V power supply, 25°C, no wind, 100% traffic)
|
Maximum power consumption [W]
|
33.80 W (60 V power supply, 60°C, no wind, 100% traffic)
|
Maximum heat dissipation [BTU/hour]
|
115 BTU/hour
|
Static power consumption [W]
|
16.2W ( 12V@25°C ); 19.2W (48V@25°C)
|
MTBF [years]
|
78.4 years
|
MTTR [hours]
|
2 hours
|
Availability
|
> 0.99999
|
Noise at normal temperature (acoustic power) [dB(A)]
|
Noise-free (no fans)
|
Noise at normal temperature (acoustic pressure) [dB(A)]
|
Noise-free (no fans)
|
Number of card slots
|
0
|
Number of power slots
|
0
|
Number of fans modules
|
0
|
Redundant power supply
|
1+1
|
Long-term operating temperature [°C(°F)]
|
Altitude of 0–1800 m (0–5906 ft.), industrial optical modules:
|
|
Installed in a sealing cabinet: -40°C to +60°C (-40°F to +140°F)
|
|
Installed in a ventilation cabinet, with the wind speed of at least 40 LFM: -40°C to +70°C (-40°F to +158°F)
|
|
Installed in a ventilation cabinet that is equipped with fans and has a fan speed of at least 200 LFM: -40°C to +75°C (-40°F to
+167°F) |
Restriction on the operating temperature variation rate [°C(°F)]
|
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the
altitude increases by 220 m (722 ft.). |
Storage temperature [°C(°F)]
|
-40°C to +85°C (-40°F to +185°F)
|
Long-term operating relative humidity [RH]
|
5% RH to 95% RH (non-condensing)
|
Long-term operating altitude [m(ft.)]
|
0–5000 m (0–16404 ft.)
|
Storage altitude [m(ft.)]
|
0-5000 m (0-16404 ft.)
|
Power supply mode
|
DC external
|
Rated input voltage [V]
|
DC input: 12 V DC to 48 V DC
|
Input voltage range [V]
|
DC input: 9.6 V DC to 60 V DC
|
Maximum input current [A]
|
5 A
|
Memory
|
2 GB
|
Flash memory
|
Physical space: 1 GB
|
Console port
|
RJ45
|
Eth Management port
|
Not supported
|
USB
|
Supported
|
RTC
|
Not supported
|
RPS input
|
Not supported
|
Service port surge protection [kV]
|
Common mode: ±4 kV
|
Power supply surge protection [kV]
|
DC power module: ±4 kV in common mode and ±2 kV in differential mode
|
Ingress protection level (dustproof/waterproof)
|
IP40
|
Types of fans
|
None
|
Heat dissipation mode
|
Natural heat dissipation
|
Airflow direction
|
-
|
PoE
|
Not supported
|
Certification
|
EMC certification
|
|
Safety certification
|
|
Manufacturing certification
|